OPERATING DATA REPORT I'
DOCKET NO. 050-0298 DATE 05-n1-89 COMPLETED BY M
't' rrhauerrnan TELEPHONE ( 4021825-3811 9
OPERATING STATUS N
5 c oner Nuclear station
- 1. Unit Nsme:
April 1988
- 2. Reporting Period:
2381
- 3. Licensed Thermal Power (MWt):
836
- 4. Nameplate Rating (Gross MWe):
778
- 5. Design Electrical Rating (Net MWe):
787
- 6. Maximum Dependable Capacity (Gross MWe):
764
- 7. Maximum Dependable Capacity (Net MWe):
- 8. If Changer Occur in Capacity Ratings (items Number 3 Through 7) Since Last Report.Give Reasons:
- 9. Power Level To Which Restricted.lf Any(Net MWe):
- 10. Reasons For Restrictions.lf Any:
3 Utis Month Yr..to.Date Cumulative 719.0 2.903.0 121. 272.0
- 11. Hours in Reporting Period 0.0 1,297.0 91,304.4
- 12. Number Of Hours Reactor Was Critical 0.0 0.0 0.0
- 13. Reactor Reserve Shutdown Hours 0.0 t,281.2 89,825.6
- 14. Hours Generator On.Line
- 15. Unit Reserve Shutdown Hours 00 00 00 0.0 2,629,440.0 177,260,147.5
- 16. Gross Thermal Energy Generated (MWH)
- 17. Gross Electrical Energy Generated (MWH) 0. 0,,,
872,027.0 56,931,108.0 0.0 840,096.0
_54,868,720.0
- 18. Net Electrical Energy Generated (MWH)
UU 44*I 74 1
- 19. Unit Senice Factor 0.0 44.1 74.1
- 20. Unit Availability Factor 0.0 37.9 59.2
- 21. Unit Capacity Factor (Using MDC Net) 0.0 37.2 58.2
- 22. Unit Capacity Factor (Using DER Net) 0.0 16.8 4.8
- 23. Unit Forced Outage Rate
- 24. Shutdowns Scheduled.Over Next 6 Months (Type. Date,and Duration of Eacht:
M3Y 19e 1988-
- 25. If Shut Down At End Of Report Period. Estimated Date of Startup:
- 26. Units in Test Status (Prior to Commercial Operation):
Forecast Achieved INITIAL CRITICALITY INITIA L ELECTRICITY hl COMMERCI AL OPERATION (9/77 :
8805200072 880430 PDR ADOCK 05000298
- rp
l-i.
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.
050-0298 UNIT CNS DATE 05-03-88 COMPLETED BY J. T. Scheuerman TELEPHONE (4021825-3811 MONTil April 1988 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
(MWe-Net)
.3 0
g7 0
0 0
_2 I8
- 3 0
19 0
4 0
20 0
5 0
21 0
0 0
6 22 7
0 23 0
8 0
0 24 9
n 25 0
10 0
26 0
il 0
0 27 12 n
23 n
13 0
29 0
~
14 0
0 30 0
0
-15 3,
16 0
4 INSTRUCTIONS On this format. list the ave age dauy unit power levelin MWe. Net for each day in the reporting month. Compute to the nearest uhole rnegaw.itt.
(9/77)
..m-_.,
=.-
o..
050-0298 IlOCKET NO.
UNITS!!UTDOWNS ANDI'OWElt REDUC 110NS UNIT NAalE CNS HA1E 05-03-88 C01tPl.ETEll itY J.
T.
Scheuerg n REPORT AIONTil April 198g 1El.E!'110NE (4021825-3811 "E
S1, Cause & Connective e
r.
3 ui
.E _e E
j.s X Licensee cw g
S'.
Date p,
3g
(
jgy n,en Ey a.3 Acehui to g$ 3 5
5 (8 g Iteport8' 81 0
$U Psevent itecurrence U
O 88-02 880305 S
719.0 C
2 N/A N/A N/A Reactor shutdown for 1988 (EOCll)
Refueling and Maintenance Outage.
t
(
l 2
3 4
l': Finced Iteason:
hiethod:
Exhibit C-Instructions S: Scheduled A Eiguipment Failure (Explain) 1-Elanua!
- for Picparation of Data 1141ainienance niTest 2-klanual Sermm.
!!nter Sheets fin 1.ieensee C Itcfueling 3 AutomaticScram.
livent Itepins (l. Ell) File INtillEG.
D Itegulatory ltestilction 4-Other (lixplahi) 0161)
E41perator Tsaining A Ucense Exainination F Administrative 5
G Operational Estur (Explain),
Exhibit !-
ne Source t'8/77 )
ll Other IExplahi)
Operations Narrative Cooper Nuclear Station April 1988 The plant remained shutdown in April for the 1988 (EOC 11) Refueling and Maintenance Outage.
o 4
e
\\ -
COOPER NUCLE AR 5T ATION kN.
.==
_ -. =- --.._.--
= _.. -.
Nebraska Public Power District
"" " "'d"O"NRM;1""^Y^ ""'
_ _.= --__
CNSS888140 May 3, 1988 Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C.
20555
Subject:
Monthly Operation Status Report for April, 1988 Docket No. 50-298 Gentlemen:
Enclosed for your information and use is the Cooper Nuclear Station Monthly Operating Status Report for April, 1988.
The report includes Operating Status, Average Daily l' nit Power Level, Unit Shutdown Data, and a Narrative Summary of Operating Experience.
Should you have any comments or require additional information regarding this report, please contact me.
Sine tel*,
m Gw G. It) Horn Division Manager of Nuclear Operations GRH/JTS:je Er. closure cc:
G. D. Watson w/ enc.