50 483 UNIT NAME CAllAWAY UNIT 1 DATE 9 06 88 COMPLETID DY T. A. Hoser TELEPHONE 314/676 9291 PART A OPEPATIONS SUMhARY R* Plant operated at approximately 100% power with the fo11oving exceptions.
- 1) On August 22, 1988 power was reduced to 65% to remove
'B' Main Feed Pucp from service in order to repair a faulty pcver supply. Full power operation resumed on August 23, 1988
- 2) On August 30, 1988 a turbine runback resulted from a
'B' Circulating Water Pump trip caused by a loose ector thermoc Nple scanner output lead. Full pcver operation resuaed on August 30 folleving repair of the loose lead.
PART B PORY AMD SATITY YALYI SLWARY None I /
S809150161 880831 Fase 1 of 4 PDR ADOCK 050004s3 R
n 1
Part C l
AVERACE ')AILY UNIT POWER LEVEL i
l DOCKET No.
50 483 VNIT NAME CALLAWAY UNIT 1 DATE 9 06 88 l
t COfLETFD BY T. A. leser 1
TELEPHONE 314/676 8291 l
J i
J
!ONTH:
August 1983 l
AVERACE DAILY PokTR LEVIL AVERACE DAILY TC4TR LEVIL M
(MWe Net)
(M Net) i I
1 1123 17 1112
{
)
2 1137 18 1137 l
1 3
1133 19 1151 I
i i
4 1136 20 1152 4
i 5
1150 21 1151 i
4 6
1150 22 1104 I
7 1129 23 791 q
l a
8 1107 24 1142 l
9 1139 25 1158 1
10 1148 26 1166
[
l i
l 11 1140 27 1164 i
12 1133 28 1172 i
13 1145 29 1173 14 1121 30 1132 15 1093 31 1167 I
l i
16 109e i
I
?
r..
2.r 4 4
I I
d
P rt D OPERAT1hc DATA REP (AT DOCKIT NO.
50 483
'! NIT NAME CALLAWAY LHIT 1 DaTE 9 06 88 COMPLETID BY T. A. Moser TELEPHONE 314/676 8291 OPERATING STATV$
(YTD CtH )
1.
RIPORTINC PERIOD: AUCUST 1988 CP0S$ HOUD9 IN RIPORTING PERIOD:
744 5855 32437.5 2.
Ct1tRENTLT AUTBORIZED 1%TR LIVIL (MWt):
3565 MAX. DEFEND. CAFACIIT (We Net): 1120*
DESICN ELECIll! CAL PATINC (MWe Net):
1171 1.
POWER LEiEL TO WICH RISTRICTED (IF ANY) (MWe* Net):
4 RIASONS FOR RESTRICIION (IF AhY):
THIS MONTH YR TO DATE CtHULATIVE 5.
EtHBER OF HOURS REACTOR WAS CRITICAL...............
744
$447.4 27426.1 6.
REACTOR RISERVE SHUTDOW HOURS.....................
0 0
0 7.
HOURS CINERATOR ON LINI............................
744 5395.0 26849.5 8
UNIT RESERVE SHUTDOW Hot 1tS........................
0 0
0 9.
CROSS THERMAL EhERGY CDERATED (WW)...............
2,590,033 18,524,091 86,795,871 10 CROS$ ELECT 1t! CAL DERCY CDIRATED (MW)............
679,870 6,289,963 29,331,683 11 N ET ELECTRICAL DERGY CENERATID (5U)..............
838,897 5,986,481 27,795,524 12.
REACICR S ERVICF, FACTOR............................
100 93.0 64.6
- 13. REACTOR AVAILABILITY FACTOR........................
100 93.0 84.6
[
14 131T SERVICE FACTOR................................
100 92.1 82.8 l
l
- 15. UNIT AVAILA31LIIT FACTOR...........................
100 92.1 82.8 L
16 UNIT CAPACITY FACIOR (Using MDC)...................
100,7*
91.3*
76.5*
(
l 17 UNIT CATACITY FACTOR (Us ing te s ign MWe )............
96.3 87.3 73.2 i
Id. UNIT FORCED OL*TACI RATE............................
0 4.27 4.12
?
19 SEUITGh3 $CEIDULID OYTR NIXT 6 HDNTES (TYPE, DATE AND DURATION OF EACH):
i 20 IT SWT DOW AT DD OF RIPORTIhC PER140, ESTIMATID DATI 0F STARTUP:
l
A uprated MDC value vill not te determined untti Iste in 1983.
Fage 3 of 4
__m
.m_
Part E 8
UNIT SIR:TDOWRS AhD F0WER REDUCTI3tS DOCKET NO.
50-483 CNIT RAPE CALIRAY IEEIT 1 DATE 9-06-88 QPfPLETED BY T. A. %ser TTH FHONE 314/676-8291 REFOKI NONTH: ADCUST 1988 METHOD 4 TTFE SifLTTINC DOWN Ts FORCED DURATION TIII RfACTOR OR DATE Sr SOrEDCLED (wx'Rs)
REASON RFICCINC F(ETR CORRECTIVE ACTIONS /(LPfG3ETS 16 8-22-88 5
0 A
1 De ste to repair the backup power supply on the
'S' P' in Feed Fump.
a 37 8-30-88 F
G A
4 Turbine rtaback due to a
'B' Circulating Water Pmp trip caused by a Icose motor thermocouple scatmer lead.
SUPMARTs REAT42 NETitre At EWIFMENT FAI!rRE (EIFIAIN) la MANUAL Br fu!NT. OR TEST 2: MA!CUAL SCRAM Cs REFLTLINC 3: AUIT9tATIC SCRAM Ds RECULATORT RIST1'ICTICIE 4: OTHER (EXI1AIN)
E OPERATLS TRAINIIIC AND LIQ 3SE EIAMIRATIO!E Fs ADMINISTFJLTIVE l
Cs CITRATIOMAL ERROR (EIFLAIN)
N CTI!ER (EIFLAIN)
Fage 4 of 4 l
1
Eu(.bNION zonuc 13 C h ayert September 6. 1988 Nuclear Regulatory Cornission Document Control Desk k'ashinsten. DC 20555 ULNRC-1829 Dear Sitt DOCKET NO2ER 50-483 CALLAk'AY PLANT UNIT 1 FACILITY OPERATING LICENSE NPF-30 MONTHLY OPERATING REPORT l
Al'Cl'ST 1988 i
The enclosed Monthly Operating Report for August 1988 is submitted pursuant to section 6.9.1.8 of the Callaway L' nit 1 Technical Specifications.
14 Y J
D. Blosser Manager. Callavay Plant
/
p10 $N1V MET /DSH/ TAM /cre Enclosure cet Distribution attached I
un una eo a. e
.x r.ww
r o
j,
- cc distribution for ULNRC-1829 l
1 with enclosures
?
Mr. Robert DePayette. Chief Project Section 1A p
U. S. Nuclear Regulatory Commission I
Region III 799 Roosevelt Read f
4 Glen Ellyn. IL 60137 i
4 Mr. Thomas Alexion (2 copies)
Office of Nuclear Reactor Regulation 1
U. S. Nuclear Regulatory Commission i
Mail Stop P-316
-t 7920 Norfolk Avenue
[
1 Bethesda MD 20014 f
NRC Resident Inspector Manager. Electric Department 1
i Misscuri Public Service Cornission j
P. O. Box 360 1
Jefferson City. Mo 65102 i
l a
\\
4 i
l i
l t
i 1
1 4
l 1
)
i I
l t
l 1
J l
4 j
i l
l i
i I
i
.