WOLF CREEK GENERATING STATION Burlington, Kansas July 1, 1984 - December 31, 1984 I

Distance Medium or Duplicate or and i

Pathway Sampled Split Sample Location Direction Date State Results Licensee Results l.

FOOD PRODUCTS 1

Garden Duplicate Hermon's 360 9/18/84 Nothing above in pCi/gm(WET)

[

vegetables garden 1 mile 9/24/84 detection limits.

Be-7.526 i.111 I-131 less than K-40 4.02 i.40 60 pCi/Kg Sr 89 & Sr 90 less than.5 pCi/kg t.

SHORELINE Duplicate WCGS 315 SEDIMENT discharge

.5 mile 10/8/84 Sr 89 0.9

  • 0.5 in pC1/gm(DRY):

core pCi/gm Cs-137.224 *.022 Sr-90 less than Ra 226:

0.2 pCi/gm 2.39

  • 0.43 Nothing else above Th-228:

detection limits.

1.36

  • 0.14 K-40:

11.4

  • 1.1 e

9603040394 860227 4y2 DR ADOCK O

1 h

~

.l 4

.s,

't WOLF CREEK GENERATING STATION 7

Burlin0 ton, Kansas July 1, 1984 - December 31, 1984

~

Distance Medium or Duplicate or and Pathway Sampled Split Sample Location Direction Date State Results Licensee Results 3

3 j

AIRBORNE Duplicate Hartford 284 pCi/m pCi/M X E particulate (Control) 15.0 Miles 7-3-84 1

2.1 1 0.4" 2.9 i-0.4-7-10-84 r

7-18-84 2.7 i 0.3 7-24-84 3.9 1 0.5 3.9 t 0.5 7-31-84

  • Licensee values invalid due.to a problem 8-7-84

. 260 i.010 1.8 i 0.3*

with air leakage around charcoal cartridges 8-14-84 1.610 i.02 1.6 i 0.3*

8-21-84

.307 1.009 1.4 1 0.3*

8-28-84

.426 i.011 1.3 1 0.3*

u; 9-4-84

.709 i.014 3.1 1 0.4 4

9-11-84

.357 i.011 3.7 i 0.4

?

9-18-84

.871 i.016 2.2 1 0.3

    • Licensee air sample taken on 9-26-84 9-25-84

.197 i.008 3.0

  • 0.3**
    • Licensee air sample taken on 10-3-84 10-02-84

.498 i.005 3.7 i 0.4**

1 10-9-84

.741 i.014 3.7 1 0.5 l

10-16-84

.097 i.006 2.0 1 0.3 10-23-84

.288 i.009 2.8 2 0.4 10-30-84

.073 t.006 2.4 1 0.4 11-6-84

.430 i.010 2.4 1 0.4 11-13-84

.106 1.006 2.9 1 0.4-

      • State air samples taken on 11-19-84 11-20-84

.003 1.003***

2.1.1 0.4 11-27-84

.465 i.012 2.4 1 0.4

,l 12-4-84

.465 t.012 3.3 1 0.4 12-11-84

.316 i.009 5.0 1 0.4 12-18-84

.052 i.004 3.5 t 0.4-12-26-84

. 062-

.004 3.4 2 0.3 1-2-85.

.060 i.004 4.0 1.0.4

~ _ _ _. _ _ _ _ _ _ _ _ _ _ _ _.. _ _ _ _ _ _ _ _ _ _. _.. _. _ _ _ _ _. _ _ _ _ _. _ _ _.. _. _, _ _ _ _ _ _. _ _ -

m

m, I

L

~

l

~

WOLF CREEK GENERATING STATION Burlington, Kansas July 1, 1984 - December 31, 1984 Distance Medium or

-Du.plicate or and Pathway Sampled Split Sample Location Direction Date State Results Licensee Results 3

3 AIRBORNE Duplicate Sharpe 360" pCi/m pCi/M X Er_2

.i

' particulate 2.8 mi 7-3-84

.113 i.006 1.7.1 0.3^

7-10-84

.230 i.004 1.4 z 0.3*

7-18-84

.373 i.005 1.4 1 0.3*

7-24-84

.747 1 0.15 1.1 1 0.3*

  • Licensee values invalid due to a problem 7-31-84

.756 1 0.15 3.2 i 0.4 l

l with air leakage around charcoal cartridges 8-7-84

.220 1 0.10 3.4 1 0.4 l

8-14-84

.580 1 0.10 3.1 1 0.4 l

8-21-84

.296 i.010

4. 0
  • 0. 4 -

8-28-84

.340 t.010 4.1 1 0.4 9-4.208 i.008 3.3 1 0.4.

9-11-84

.205 1.008 3.9 1 0.4

.J 9-18-84

.154 i.007 2.3 1.0.3

    • Licensee air samples taken on 9-26-84 9-25-84

.083 i.006 3.2 1;0.3**

Licensee air samples taken on 10-3-84 10-2-84

.271 i.004 3.4 i+0.4**

10-9-84

.418 i.012 3.5 1 0.5

' '6 10-16-84

.069 1.005.

2.1 1 0.4 10-23-84

.144 i.007 2.8 i 0.4 10-30-84

.061 i.005

. 2.8 t 0.4 11-6-84

.147 i.007 2.4 1 0.4 l

11-13-84

.169 i.007 2.2 1 0.3

~'

      • State air sample taken on 11-19-84

.-,11-20-84

.059 1.0068**

1.7 1 0.3, s 11-27-84

.146 1.006 3.2 1 0.4 1

12-4-84

.242.

.008 3.3 1 0.4 12-11-84

.251

.008 4.7 0.4 12-18-84

.086

.005 3.3 i 0.4 12-26-84.

.104 1.006 4.1 1 0.4 1-2-85

.076 t.006 3.3 0.4 l

l

\\

i

~.

v

WOLF CREEK GENERATING STATION

~

Burlington, Kansas July 1, 1984 - December 31, 1984 i,

Distance Medium or Duplicate or and Pathway Sampled Split Sample Location Direction Date State Results.

Licensee Results

,v I

AIRBORNE ilattford 285 3rd Quarter Nothing aoove (Be-7) 8.56. t 1. 2 E-2 M-particulates (Control) 15.0 miles 4th Quarter detection limits- (Be-7) 6.29 i 0.63 E-2 gamma isotopic for monthly gamma composites 1

7/1/84-12/831/84 Sharpe 360*

3rdQuarter Nothing aoove (Se-7) 1.01 0.10 E-1 1

2.8 mi.

detection limits (K-40)8.97 1 3.89 E-2 S

4th Quarter for monthly. gamma (Be-7)7.00 1 0.72 E-2 composites,

.(

7/1/84-12/31/84 AIRBORNE duplicate Hartford 285*

No radiodine was found above detection ' limits for 2

radiotodines 15.0 miles licensee or state analyses for 'f1/84-12/31/84 at Sharpe 360 either location.

i 2.8 miles WATERBORNE duplicate John 270 Monthly samples Gamma: Nothing Gamma: Nothing above Surface water Redmond 3.5 miles collected on above detection detection limits for gamma &

Reservoir the same day limits for monthly monthly samples.

quarterly Tritium:

tritium 3rd Quarter 0.0 0.2 nCi/1 Tritium: r.othing

~

4th Quarter 0.2 1 0.2 nCi/1 above detection limits for sa:aples, 4,

2m

. e m.

s m

=

e w

eui--

+

a

~&

2 4

- M

l

.. ~

1g7;

]

~'

k,

'4C WOLF CREEK GENERATING STATION-4-

Burlington, Kansas July 1, 1984 -~ December 31, 1984 Distaace Medium or.

-Duplicate or and Pathway Sampled Split. Sample Location Direction Date State Results Licensee Results 7

Tritium split WCGS 315 Monthly Gamma: nothing -=

147 1 15 pCi/1 discharge

.5 mile samples above detection

- K-40 on 9-18-84; cove limits for monthly no other nuclides samples.

found at detection Tritium:

3rd quarter 0.2 1 0.2 nCi/1 4th quarter 0.0 1 0.2 nCi/l

s

.c INGESTION:

MILK Duplicate Redding 45*

Monthly gamma. isotopic-and radiciodines:

Dairy 5 miles samples taken nothing above K-40 found as follows on-same day detection limits 7/84 1180 1 120 pCi/1 Analyzed for I-131, 8/8411501120 pCi/l i

Cs-137,.and Ba-140. 9/84.1330 1 130 pCi/l-Sr-89/Sr-90 10/84 1200 1 120 pCi/1 determinations 11/84 1200 1 130 pCi/1 on July sample.

12/84 1340 130 pCi/1 (Sr-90:.2.3 i

.5 pCi/1)

FISH Split Wolf Creek 10/13/84 Channel catfish /

K-40 in pCi/gm:

Reservoir

. wiper hybird:

Channel Catfish /

~

Nothing above Wiper Hybrid detection limits, 3.92 1 0.39

~ - '

'- No other nuclides above detection limits.

. -a-

~_

WOLF CREEK GENERATING STATION Burlington, Kansas July 1, 1984 - December.31, 1984 Distance Medium or Duplicate or and Pathway Sampled Split Sample Location Direction Date State Results Licer,see Results F000 PRODUCTS Garden Duplicate Hermon's 360 9/18/84 Nothing above in pCi/gm(WET) vegetables garden 1 mile 9/24/84 detection limits.

Be-7.526 i.111 I-131 less than K-40 4.02 f.

40-60 pCi/Kg Sr 89 & Sr 90 less than.5 pCi/kg SHORELINE -

Duplicate WCGS 315 SEDIMENT discharge

.5 mile 10/8/84 Sr 89 0.9

  • 0.5 in pCi/gm(DRY):

core pCi/gm Cs-137.224 *.022 Sr-90 less than Ra 226:

0.2 pC1/gm 2.39

  • 0.43 Nothing else above Th-228:

detection limits.

1.36

  • 0.14

.K-40:

11.4

  • 1.1-

[

l l L -

WOLF CREEK GENERATING STATION Burlington, Kansas October, 1983 - December, 1984 Sample Type:

TLD-Direct radiation Duplicate or Split Sample:

Duplicate 1

l?

Distance Location and b

c l,

NRC/KG&E/KS Direction Date NRC Results" Licensee Results State Results 3/2/--

360 10/83 - 1/84 21.7 1 4.6 16.0 1 0.9 l

2.8 miles 1/84 - 4/84 15.4 1 3.9 15.9 i 0.1 l

4/84 - 7/84 23.4 1 3.5(g) 16.3 1 0.3 7/84 - 10/84 15.4 1 3.8 17.2 1 0.6 10/84 - 1/85 19.6 1 5.6 18.3 1 0.6 4/1/A1 355 10/83 - 1/84 17.4 4.1 16.6 1 1.2 19.5 1 2.7 1.6 miles 1/84 - 4/84 18.5 1 4.3 17.8 1 0.4 19.0 1 2.5 l

4/84 - 7/84 23.5 1 3.5(g) 18.0 1 0.9 17.8 1 2.8 7/84 - 10/84 16.6 1 4.0 18.0 1 0.4 19.5 i 1.9 10/84 - 1/85 20.1 1 5.7 18.8 1 0.1 19.2 1 2.5 l

8/-/El 90*

10/83 - 1/84 23.4 i 4.8 18.9 1 2.3 l'

1.7 miles 1/84 - 4/84 18.2 1 4.3 17.7 1 2.8 4/84 - 7/84 22.4 1 3.4(g) 17.9 1 2.4 L

7/84 - 10/84 16.0 3.9 19.0 1 2.4 10/84 - 1/85 20.2 1 5.7 18.8 1 2.7 10/14/G1 13.7 10/83 - 1/84 25.0 1 5.0 18.1 1 0.6 20.1 1 2.3 2.5 miles 1/84 - 4/84 19.7 4.5 18.4 1 1.3 19.1 1 2.7 L

4/84 - 7/84 23.7 1 3.6(g) 17.7 1 0.3 19.3 2.5 l

7/84 - 10/84 17.5 1 4.1 19.8 1 0.6 21.1 2.2 l

10/84 - 1/85 20.7 1 6.7 20.3 1 0.1 20.1 1 3.8 12/20/--

184 10/83 - 1/84 21.5 i 4.6 17.4 1 0.0 3.3 miles 1/84 - 4/84 18.6 1 4.3 17.7 1 0.4 4/84 - 7/84 23.7 3.6(g) 17.2 0.7 l

7/84 - 10/84 15.1 1 3.8 18.4 0.1 l

10/84 - 1/85 20.2 1 5.7 19.0 1 0.4 l

~

WOLF CREEK GENERATING STATION Burlington, Kansas October, 1983 - December, 1984 Sample Type:

TLD-Direct radiation Duplicate or Split Sample:

Duplicate Distance Location and a

b c

NRC/KG&E/KS Direction Date NRC Results Licensee Results State Results 13/29/K1 213 10/83 - 1/84 17.4 1 4.1 14.7 1 0.6 19.3 1 2.5 2.9 miles 1/84 - 4/84 18.0 1 4.2 14.6 i 0.0 17.7 1 2.8 4/84 - 7/84 24.4 i 3.7(g) 14.2 1 0.4 18.2 1 2.7 7/84 - 10/84 15.2 1 3.8 15.3 i 1.6 20.0 1 2.4 10/84 - 1/85 20.8 1 5.7 15.1 1 0.1 19.2 1 3.4 14/27/L1 233 10/83 - 1/84 22.4 i 4.7 16.6 1 0.1 18.1 1 2.8 2.4 miles 1/84 - 4/84 18.1 1 4.3 17.3 1 0.1 15.8 1 2.6 4/84 - 7/84 23.2 1 3.5(g) 16.9 1 0.6 17.0 1 2.9 7/84 - 10/84 15.6 1 3.9 18.2 1 0.9 17.6 1 2.1 10/84 - 1/85 19.6 1 5.6 17.8 1 0.0 17.4 1 3.6 17/25/--

270 10/83 - 1/84 19.7 4.4 13.5 i 1.3 3.4 miles 1/84 - 4/84 13.9 i 3.7 14.0 1 0.2 4/84 - 7/84 19.2 1 2.9(g) 13.2 1 0.1 7/84 - 10/84 12.4 1 3.5 14.5 0.1 10/84 - 1/85 17.0 1 5.4 14.3 1 0.4 26/6/-

67 10/83 - 1/84 22.2 4.7 15.7 0.6 4.3 miles 1/84 - 4/84 16.2 4.0 15.3 1 0.6 4/84 - 7/84 22.1 1 3.3(g) 15.8 1 0.1 7/84 - 10/84 14.4 3.7 17.2 i 1.0 l

10/84 - 1/85 19.3 1 5.6 18.0 0.1 18/15/-

110 10/83 - 1/84 22.9 i 4.8 16.6 1 0.5 l

4.5 miles 1/84 - 4/84 18.5 1 4.3 17.9 1 0.6 4/84 - 7/84 23.2 1 3.5(g) 16.0 0.1 l

7/84 - 10/84 16.7 1 4.0 18.3 1 0.1 10/84 - 1/85 18.8 5.6 19.1 1 2.4 l

l k

i WOLF CREEK GENERATING STATION Burlington, Kansas October, 1983 - December, 1984 Sample T.vpe:

TLD-Direct radiation Duplicate or Split Sample:

Duplicate Distance Location and a

b c

NRC/KG&E/KS Direction Date NRC Results Licensee Results State Results

'36/23/--

224*

10/83 - 1/84 20.5 1 4.5 15.7 1 0.4 4.8 miles 1/84 - 4/84 16.4 1 4.0 16.7 1 0.1 4/84 - 7/84 missing 7/84 - 10/84 14.3 1 3.7 10/84 - 1/85 18.3 1 5.5 16.8 i 0.4 40/40/P2

.285 10/83 - 1/84 20.5 1 4.5 15.7 i 0.3 17.4 1 2.4 15 miles 1/84 - 4/84 14.6 1 3.8 15.2 1 0.3 16.5 1 2.6-4/84 - 7/84 20.3 1 3.0(g) 15.3 1 0.4 18.2 1 2.7 7/84 - 10/8'4 13.3 1 3.6 15.1 1 0.6

-16.0 1 1.8-10/84 - 1/85 16.3 1 5.4 16.1 1 0.1 16.6 1 3.7 42/39/-

345 10/83 -.1/84 19.7.1 4.4 16.8 1 0.6 13.-miles 1/84 - 4/84 17.5 i 4.2 16.4 1 0.1 4/84 - 7/84 24.4 1 3.7(g) 16.4 1 0.1 7/84 - 10/84 16.9 i 4.0 17.6 1 0.8 10/84 - 1/85 20.8 i 5.7 17.8 i 0.1 15.9 1 1.1 18.3 1 2.5

-/9/01 60 10/83 - 1/84' 16.1 1 0.6 16.9 1 2.8

-2 miles 1/84 - 4/84 4/84 - 7/84 16.3 1 0.1 17.8 i 2.5 16.8 1 0.1 18.0 1 2.3 7/84 - 10/84 18.1'i 1.1 18.3 1 3.2 10/84 - 1/85

-/26/M1 240 10/85

.1/84 15.7 1 0.3 17.8 i 2.3 16.1 1 0.3 15.4 1 2.5 2.5 miles 1/84 - 4/84 4/84 - 4/84 15.6 1 1.1 16.9.1 2.5 7/84

~7/84 16.5 1 0.7 17.4 1 2.1 16.7 1 0.3

-17.3 1 3.8 10/84 - 1/85

s' WOLF CREEK GENERATING STATION Burlington, Kansas October, 1983 - December, 1984 Sample Type:

TLD-Direct radiation Duplicate or Split Sample:

Duplicate s

Distance Location and a

b c

NRC/KG&E/KS Direction Date NRC Results Licensee Results State Results

--/32/P1 300 10/83 - 1/84 17.0 1 0.4 19.1 1 2.6 2.75 miles 1/84 - 4/84 16.8 1 0.2 22.1 1.3.1 4/84 - 7/84 17.2 1 1.2 15.7 1 2.5 7/84 - 10/84 18.2 1 1.2 18.6 1 2.1 10/84 - 1/85 17.8 1 0.8 18.7 1 3.0

--/31/R1 355 10/83 - 1/84 16.4 1 0.0 15.9 i 2.8 2.0 miles 1/84 - 4/84 15.8 1 0.1 16.1 1 2.6 4/84 - 7/84 15.3 1 0.4 16.6 1 2.5 7/84 - 10/84 16.9 1 1.1 17.4 1 2.1 10/84 - 1/85 16.7 1 0.1 15.5 1 0.3 (g) indicates NRC gross data, not net, available only.

a.

NRC results expressed as normalized net 90-day quarter data i total uncertainty, except where indicated as gross data (g).

b.

Licensee results expressed as a normalized 90-day quarter average i one standard deviation of two dosimeters at each location.

c.

State results expressed as normalized 90-day quarter average i total uncertainty.

Three dosimeters are at each Icration.

18/H l

1 !

l l