Documents Concerns Identified During Part of Special Insp on 860121-24 to Examine Bechtel Audit Program & Util Weld Reinsp Program.Formal Rept Will Be Issued in Near Future
ML20154A516
Person / Time
Site: Sequoyah  
Issue date: 02/26/1986
From: Youngblood B
Office of Nuclear Reactor Regulation
To: White S
TENNESSEE VALLEY AUTHORITY
References
NUDOCS 8603040069
Download: ML20154A516 (3)


Text

p oen f

o,'g UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON D. C. 20555

/,a g

FU :: 6 1986 Docket Nos.: 50-327 and 50-328 Mr. S. A. White Manager of Nuclear Power Tennessee Valley Authority 6N 38A Lookout Place 1101 Market Street Chattanooga, Tennessee 37402-2801

Dear Mr. White:

Subject:

Special Inspection of January 24, 1986 on Welding Concerns -

Sequoyah Nuclear Power Plant On January 21 to 24,1986, NRC staff conducted part of a special inspection to examine Bechtel's Audit program and TVA's weld reinspectfen program at Sequoyah, The staff identified several concerns which were discussed with your personnel at the exit interview. This letter documents those concerns.

Those concerns were as follows:

1.

Because of parallel efforts in performing reinspections while still providing submittals to NRC, reinspections were not being performed exactly in accordance with written comitmants.

Inspection procedures which were being used for PT and MT were written to ASME Section XI. The January 17, 1986, submittal to NRC speci,fied reinspections were to be to ANSI B31.1 and B31.7, 2.

In the " Program Description" submitted to NRC dated January 17, 1986, the terms " adequate for service" and " meet all ccmmit-ments and requirements" appear to be used interchangeably, These tems are not the same. NRC considers that the audit and reinspection program should first detcrmine if commitments and requirements are met. The next step would be to determine

" adequacy for service."

3.

The person in a supervisory / coordination position over the reinspection progran was the same person supervising inspection personnel during original construction. After questions were raised by NRC, that person was relieved of the responsibility.

kopOjpgCK69 e60226 050003 7 O

PD

O

,M r.

S. A. White Tennessee Valley Authority Sequoyah Nuclear Plant cc:

Herbert S. Sanger, Jr., Esq.

Tennessee Department of Public General Counsel Health Tennessee Valley Authority ATTN: Director, Bureau of 400 West Summit Hill Drive, E 118 33 Environmental Health Services Knoxville, Tennessee 37902 Cordell Hull Building Nashville, Tennessee 37219 Mr. K. W. Whitt Mr. Michael H. Mobley, Director Tennessee Valley Authcrity Division of Radiological Health 400 West Summit Hill Drive, E3A8 T.E.R.R.A. Building Knoxville, Tennessee 37902 150 9th Avenue North Nashville, Tennessee 37203 Mr. Bcb Faas Westinghouse Electric Corp.

County Judge P.O. Box 355 Hamilton County Courthouse Pittsburgh, Pennsylvania 15230 Chattanooga, Tennessee 37402 Mr. Jerry Wills Tennessee Valley Authority SN 133 Lookost Place Chattanooga, Tennessee -37a02-2801 Mr. Donald L. Williams, Jr.

Tennessee Valley Authority 400 West Summit Hill Drive W10385 Knoxville, Tennessee 37902 Resident Inspector /Sequoyah NPS c/o U.S. Nuclear Regulatory Commission 2600 Igou Ferry Road Soddy Daisy,. Tennessee 37379 Regional Adninistrator, Region II U.S. Nuclear Regulatory Commission, 101 Marietta Street, N.W., Suite 2900 Atlanta, Georgia 30323 Mr. Everett Whitaker Tennessee Valley Authority SN 1288 Lookout Place Chattanooga, Tennessee 37402-2801 l

~

FEB 2 6 1986 Mr. S. A. White 2_

4.

For the audit, Bechtel does not require double checking of the audit activities.

5.

The MT procedure being used did not contain details for calibration of the MT yoke.

This letter does not require a response. A formal inspection report will be issued in the near future.

Sincerely, 3/

B. J.'Youngblood, Director PWR Project Directorate #4 Division of PWR Licensing-A, NRR cc: See next page jlSTRIBUT-ION:

C _ Docket Fily)

NKL VUK L PDR NSIC PRC System PWR#4 R/F MDuncan WLong BJYoungblcod R/F EJordan BGrimes JPartlow ACRS (10)

OELD HThompson BDLiaw DVerrelli BCrowley LSpessard DSmith PCortland JVtkOtch 9

?

I I

FWR

-A

'n PWH#4: WR-A WLongi b'

a BJYoungblood 02/{((//86 02/ 4 /86 02

/86

_