AUG 2 9 1988 Docket No. 70-1100 License No. S M-1067 Amondment No. 14 Combustion Engineering, Inc.
ATTN: Dr. P. L. McGill, Vice President Nuclear Fuel 1000 Prospect Hill Road Windsor, Connecticut 06095-0500 Gentlaun:
In accordance with ymr revised application dated August 16, 1988, and supplements dated AupJst 19, and August 23, 1988, and pursuant to Title 10,
)
Code of Federal Regulations, Part 70. Materials License No. S2-1067 is hereby amended to authorize use of uranium enriched to a maximum 5.0 weight percent in i
the U-235 isotope. Condition No. 9 has been revised ta include the dates of i
August 16 and August 19, 1988, and Chapter 8, Part II. of the application. This authorization is subject to the following additional license conditions:
- 26. Hydrogenous materials shall not be stored on pellet storage tables 1
or pellet storage racks where nuclear criticality safety is based on i
4-inch safe slab limits.
- 27. Hydrogenous materials shall not be stored between trays of fuel rods on storage racks or shelves where nuclear criticality is based on 6-inch safe slab limits.
]
- 28. A transition period is allowed to switch from the use of poly-buckets to stainless steel buckets. During this period, all i
special nucitar material containing not more than 4.1 wt% U-235 I
will be shifted to stainless steel buckets 5 stainless steel buckets shall be used for all special nuclear material containing more than 4.1 wt% but not more than 5.0 wt% U-235. Stainless steel buckets shall replace all poly-buckets by November 30, 1988.
29.
In accordance with your letter dated August 23, 1988, a period of not more than thirty (30) days from the date of this amendment is authorized to imp'ement changes to bring the dryer belt into conforsance with license descriptions. Specifically, modifications shall be made to the dryer belt assembly described in Section 8.1.4.1 to limit the maximum physical space below the dryer belt to 3.5 inches. During this period, the weekly inspection, specified in Section 8.1.4.1, shall be conducted on at least a daily basis to assure that powder does not accumulate to more than 1/2 inch. Any accurulatio.: of powder greater than 1/2 inch shall result in a removal of accumulated l
power. Records of inspections and powder removal shall be maintained for six months.
p h!
kb 0
Il C
I l
AUG 2 9 038 Combustion Engineering, Inc.
2 Condition No. 25 M hereby terminated. Note that Chapter 8. Part II of the application has been incorporated into the license. All other conditions of your license shall remain the same.
The above conditions were discussed, and agreed to, by your Mr. Molnar and George Bidinger of my staff on August 26, 1988, t
Enclosed are copies of revised License No. SNM.1067 and our Safety Evaluation Report.
FOR THE NUCLEAR REGULATORY COMMISSION M Si8ned b 1
i.
]
Leland C. Rouse, Chief Fuel Cycle Safety Branch l
Division of Industrial and i
Medical Nuclear Safety, NMSS
Enclosures:
1.
Revised License No.
SNM-1067 2.
Safety Evaluation Report cc w/encis:
Mr. A. E. Scherer Director Nuclear Licensing Mr. C. B. Brinkman, Manager Washington Nuclear Operations Mr. C. R. Waterman, Plant Manager Windsor Fuel Manufacturing
)
]
Mr. R. E. Sheeran, Manager Licensing Safety, Accountability i
and Security i
RIBUTION w/encls.
j i
D O-1100, PDR NMSS R/F IMSB R/F VLTharpe GHBidinger(2)
Region I GJackson, LFMB GBennington, SGTB GMcCorkle.SGTR SH0 JRoth Region I MLHorn IMUF R/F LCRouse JJSwift j
OFC:IMUF: y g y
F:\\
Il F
I
.fd........
j NAME:GHBidinger:mh:
J LTharpe:
,J ft:
ouse:
y l
DATE:8M /88:
8hPj88:
8/24/88:
8/tf/88: