ML20153D591
| ML20153D591 | |
| Person / Time | |
|---|---|
| Issue date: | 10/31/1997 |
| From: | Collins S NRC (Affiliation Not Assigned) |
| To: | Burrows F NRC (Affiliation Not Assigned) |
| Shared Package | |
| ML20153D328 | List: |
| References | |
| NUDOCS 9809250108 | |
| Download: ML20153D591 (1) | |
Text
. - - _.
. _ ~..
October 31, 1997 MEMORANDUM TO: Frederick H. Burrows, Electrical Engineer Electrical Engineering Branch Division of Engineering ggg FROM:
Samuel J. Collins, Director C M ; COM Office of Nuclear Reactor Regulation
SUBJECT:
DIFFERING PROFESSIONAL VIEW CONCERNING TECHNICAL SPECIFICATION TRIP SETPOINTS AND ALLOWABLE VALUES FOR INSTRUMENTATION in a memorandum dated March 17, igg 7, you expressed your differing professional view regarding Technical Specification trip setpoints and allowable values for instrumentation. The NRR Ad-Hoc Review Panel reviewed your concems. The report on their review, findings, and roco,nmendations is enclosed.
I have requested the staff to roview the Panel's recommendations and develop appropriate actions to address the Panel's findings on your concerts. Thank you for bringing this matter to msnagement'n attention.
Enclosure:
As stated DISTRIBUTION:
AJMendiole OFFICE ADPR;NRR NAME
% RPZfmmerman h
DATE 10/3' /g7 OFFICIAL RECORD COPY 9809250108 980915 PDR TOPRP EMVWEST C
PDR b0'lbO/OW
.