n h Commonwealth Edison

'-' 72 West Adams Street, Chicago, Illinc;s

., J Address Reply to: Post Office Box 767 U Chicago, Illinois 60690 - 0767 February 4, 1986-PRIORITY ROUTIflG first sec3nd Mr. James G. Keppler h44; j[g Regional Administrator or

l7 Trotter's Dairy Tritium Quarterly On quarterly composite from each location. BD-18 Biros Farm Gamma Isotopic Quarterly On quarterly composite froa each location. Sr-89,90 -Quarterly on quarterly composite from each location. 8. Well Water-BD-13 Braidwood City Weekly Gross beta Quarterly On quarterly composite. Offsite Hall Well Tritium Quarterly Gamuna Isotopic Quarterly Sr-89,90 Quarterly 9., vegetables BD-14 Pinnick Farm Annually Gross beta Annually Four varieties from each location as BD-15 Girot Fara Gamuna Isotopic Annually available at harvest. I-131 on Leafy BD-16 Clark Farm Sr-89,90 Annually veg. 1-131 Annually 10. Cattle Feed Same as 7. Quarterly Gross beta Quarterly Grass: Summer - May to October 7'. Gamma Isotopic Quarterly Feed: Winter - November to April and Grass Sr-89,90 Quarterly 11.-Milk .Same as 7. -Weekly:May-Oct Gamma Isotopic Weekly:May-Oct On all samples. Monthly: Sr-89,90 Monthly: On monthly composites. Nov-April I-131 Nov-April On all samples. 12. Bottom BD-07 Upstream 3 times a year Gross beta 3 times On all samples. Sediments BD-10 Downstreat Gamma Isotopic a year On all samples. 13. Aquatic Same as 12. 3 times a year Gross beta 3 times If available. Plants Gamma Isotopic a year 0521X/2 e 9 O l STANDARD RADIOLOGICA1, MONITORING PROGRAM BRAIERf00D STATION (continued...) Sample 1,ocation Collection Type of Frequency of Media Code Site Frequency Analysis Analysis-Remarks 14. Fish BD-10 Downstream 3 times a year Gross beta 3 times From Kankakee River Monitoring Site #5 Kankakee River Gamma Isotopic a year on edible portions only; at least BD-07 Upstream Sr-89,90 two species. Kankakee River

15. -Dairy a.

' Site boundary a. Enumeration Annually During grazing season. Census 2 miles by a door-to-door or equivalent counting technique. b. 2 miles to 5 miles b. Enumeration Annually During grazing season, by using referenced information from county agricultural agents or other reli-able sources,

c. At dairies listed in
c. Inquire as to feeding Annually During grazing season.

Item 7 practices:

1) Pasture only.
2) Feed and chop only.
3) Pasture and feed; if both, ask farmer to estimate fraction of food from pasture: <25%,

25-50%, 50-75%, or >75%. Lt. 0521x/3 s I b D .