Application for Amend to License DPR-59,changing Tech Specs as Result of Mods to Standby Liquid Control Sys to Ensure Min Flow Capacity & Boron Content Equivalent to 86 Gpm of 13 Weight Percent Sodium Pentaborate Solution
ML20153C458
Person / Time
Site: FitzPatrick 
Issue date: 08/24/1988
From: Brons J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
Shared Package
ML20153C455 List:
References
NUDOCS 8809010151
Download: ML20153C458 (2)


Text

.

BEFORE THE UNITED STATES NUCLEAR REGULATORY COMMISSION In the matter of

)

NEW YORK POWER AUTHORITY

)

Docket No. 50

  • 3 James A. FitzPatrick Nuclear Power Plant )

APPLICATION FOR AMENDMENT TO OPERATING LICENSE l

Pursuant to Section 50.90 of the Nuclear Regulatory Commission, the New York Power Authority, as holder of Facility Operating License No. DPR-59, hereby applies for an Amendment to the Technical Specifications contained in Appendix A of this license.

This proposed amendment to the James A. FitzPatrick Technical Specifications reflects changes to the Standby Liquid Control System (SLCS).

In accordance with the requirements of 10 CFR 50.62, changes to the SLCS are being made to ensure a minimum flow capacity and boron content equivalent to 86 gallons per minute of 13 weight percent sodium pentaborate solution.

In addition to meeting 10 CFR 50.62 requirements, to permit an increase in reload enrichment and energy content in future core design reloads, the final in-vessel boron concentration following injection of standby liquid control solution is being increased from 600 ppm of natural boron to G60 ppm of equivalent natural boron.

The proposed change to the Technical Specifications is.

Attachment I to this Application for Amendment to the Operating License.

The Safety Evaluation for the proposed change is included as Attachment II.

NEW YORK POWER AUTHORITY By A 8809010151 880824 JhhC. Brons PDR ADOCK 05000333 xecutive Vice President P

PNU '

uClear Generation STATE OF NEW YORK COUNTY OF WESTCHESTER Subscribed and sworn to before me this 84 day of 4A4ua7 1988.

U QA%

H Notary Public nNotDtfN60,.%

f.: ASH 437 h

CDa*

Jea 3

ATTACHMENT I TO JPN PROPOSED TECHNICAL SPECIFICATION CHANGES REGARDING STANDBY LIOUID CONTROL SYSTEM (JPTS-88-08)

NEW YOD.K POWER AUTHORITY JAMES A.

FITZPATRICK NUCLEAR POWER PLANT DOCKET NO. 50-333 DPR-59 e.

,.. _ _,., -,.... ~... -,..,. -....,, -,.