REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE 1

i.

l

.c HCL _1. NR-3 0 0 - S - 8 8 3 - S gm SEP 141990 PACE 1 Or s SOURCE ~ TYPE:

Industrial Radiography Source Assembly L-MODEL:

"IN"' Series MANUFACTURER / DISTRIBUTOR:

Gamma Industries, Inc.

P.O.. Box 2543 Baton Rouge, Louisiana 70821 ISOTOPE:

MAXIMUM ACTIVITY:

LIridium-192'.

120 Curies (4.44 TBq) l l LEAK TEST FREOUENCY:

6 Months 1.

l PRINCIPAL USE:

(A) Industrial Radiography CUSTOM SOURCEt~

YES x

NO i

I l

l-t 1

l 9909230353 990914 L

PDR RC 88D PDR f;

l REGISTRY.0F RADIOACTIVE SEALED SOURCES AND DEVICES

- SAFETY EVALUATION OF SEALED SOURCE l

NO.:.NR-300-S-883-S

- DATE: SEP 141988 PAGE 2 OF 5 SOURCE TYPE:

Industrial Radiography Source Assembly RESCRIPTION:

The Gamma Industries Model."IN" series source assemblies are

' designed for use only in the Industrial Nuclear, Model' IR-100, exposure-device.

The first two characters in the source model designation indicates that the source assemblies are designed for use in Industrial Nuclear exposure devices.

The middle character (numeral) is a code for the dimension of the source assembly.

The third (last) character =in the source model number designates the. type of connector.

A" indicates the Gamma Industries long saf-T-Key connector, "G"

indicates the Gamma Industries short Saf-T-Key, "T"~ indicates the Tech-Ops connector and "TG" is the shorter' Gamma industries. version of the Tech-Op connector.

All' iridium sources are' doubly encapsulated.

The minimum wall

. thickness of is 0.030" (0.76 mm).

All source capsules are fabricated the outer encapsulation from Type 304 or 316 stainless

. steel using a heliarc (TIG) welding technique with end-cap or side circumferential weld method for capsule closure.

The pigtail. connector, source. capsule, and locking ball on all source assemblies are. crimped either to 3/16" (4. 76 rmn) Tel'eflex cable or11/8" (3.18 mm) stainless cable.. Pigtail dimensional

' tolerances are. maintained at.r 1/16" (i 1.59 mm).

l LABELING:

sThe~ source capsules are not large enough to allow direct labeling; however, the exposure device which contains the source

' capsule'isilabeled.

For: additional labeling information, please refer to the particular' exposure device in which the source is to be-used.

i I

1

.E -

,, k -

a w<r 4

w w

y y w 4-

.e e

l

v

\\

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALCL' SOURCE NO.: NR-300-S-883-S DATE:

SEP 141998 PAGE 3 OF 5 SOURCE TYPE:

Industrial Radiography Source Assembly DIAGRAM See attachment 1.

CONDITIONS OF NORMAL USE:

The Gamma Industries Model IN-1-T, IN-1-TG, IN-1-A and IN-1-G source assemblies are designed for use in the Industrial Nuclear Model IR-100 industrial radiography exposure device.

These source assemblies may be used with the Gamma Industries Model C-10 source changer.

PROTOTYPE TESTINGr The "IN" series source assembly uses a doubly encapsulated universal capsule.

The manufacturer states that prototype sources have met the criteria specified in ANSI publication N542-1977 and have been assigned a classification of ANSI 77E43515.

This source series.also has an IAEA Certificate of Competent Authority, Special Form Radioactive. Material. Encapsulation, Certificate Number USA /0166/S, Revision 1.

Based on prototype test data, these designs are expected to retain containment integrity under accident conditions most likely to occur during normal use or transportation.

l L

,_....____m._

l l

)

i REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY' EVALUATION OF SEALED SOURCE NO.:.NR-300-S-883-S DATE:

PAGE 4 OF 5 gp y 4 gg Industrial Radiography Source Assembly

' SOURCE TYPE:

l OUALITY ASSURANCE AND CONTROL:

i L

- In addition to the other tests, each pigtail assembly is subjected to a 180 lb. (81.65 kg) pull test prior to radioactive

- material insertion and subjected to a wipe test after the material'is se.21ed in the capsule.

If'the results of the wipe

- test indicates contamination greater than 0.001 pCi (37 Bq) then an ethylene glycol bubble test is performed.

If the bubble test is positivo, then the; capsule is reworked or disposed of, as applicable.

Source activities are checked against a standard by using an ion chamber.

A decay chart and' source tag are supplied with each source; p*oviding'information concerning the activity r

L l

and leak test.results..

i LIMITATIONS AND/OR OTHER' CONSIDERATIONS OF'USE:

A.

Series "IN" sources shall;be distributed only to specific

_3 licensees of thetU.S.-Nuclear Regulatory-Commission or Agreement States.

~

B.

' Series'"IN": sealed sources shall not be subjected to environmental or other conditionsJof use which exceed ANSI classification 77E43515.

C.N~. Series "IN" sources shall be leak tested at intervals not to exceed sin' months using techniques approved by the licensing authority and capable of detectihg at least 0.005 microcurie

-(185 Bq) of removable contamination.

')

~~!;

L

9 r

L l

l l-REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE I

NO.:. NR-300-S-883-S EATE:

SEP 141999 PAGE 5 OF 5 i

SOURCE TYPE:

Industrial Radiography Source Assembly i

SAFETY EVALU/JfION The'Model'"IN" Series source is no l'onger manufactured'or distributed by Gamma Industries, Inc. and Gamna Industries, Inc.

-is'no longer'in business.

Therefore, the registration

(

certificate'is being converted to an inactive registration certificate.

- The source was originally approved for licensing purposes by the Louisiana Division of Radiation Control.

NRC attempted to obtain copies of all.-information submitted by the registrant in support of the evaluation.

However, NRC could not locate all the information.

Therefore, no safety evaluation of the source was performed as:part of the conversion of the certificate to inactive status.

REFERENCESt Letter from Gamma < Industries dated June 6, 1985, and June 11, 1985.

i ISSUING AGENCY;

-?

U.S. Nuclear Regulatory Commission

/

SEP 141998 Reviewer:

//'

i>

Date:

John W.'Lubinski

~

Date:

Concurrence: YhdA [ n < < pee 4-Michele L. Burgess L

e n

REGISTRATION OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE NQ1 NR-300-S-883-S DATE:

$[p 1 4 ]ggg ATTACHMENT 1 Y

(R/MPED 6N I

5 n.....--.-....

/

s

\\

s o

[L=7t=/

M'=/: m % 7 T7.=r7+=P***/M Tmn W W

(

}

/

s (N/AffEb ON ~

,,T CAlbuLE, /2/ Alum 3 E.

Ral Boot.cas

/ LA 3

(ABL E, STEND S. S.

1.52 7adI JD3 7 lN.

2 40fflUC BALL 60/60/S EJI

/ EA.

I CO t/A/EC 76K ~ TG" Bil 8003 /N.

I EA NO.

DESCRIPTION PART NO, QTY.

k

a o

PAGEi NRC FORM 567 U. S. NUCLEAR REGULATORY COMM6SSION teen REQUEST FOR A SEALED SOURCE OR DEVICE EVALUATION I

INSTRUCTIONS: Send tNs request AND a copy of ad related letterstappucatene and drawings to: The Sealed Source Safety Secten, ATTN: Chef, OWFN Mail Stop 6 H3. Change trw License Tracking System rnilestone to 19 and assign to reviewer code B-5.

NOTE: Retain a copy of this request with tra application and background files.

NEcussrER REGION / LOCATION:

l

/2M4)**/7 i ) /!/ /A TELEPHCPiE NUM8ER DATE

~

_ / #f

]I R 11 Ill IV RV HQ R LFDCB TYPE OF ACTION REQUESTED (Check as appeopriate)

APPUCANTS NAME SOURCE REVIEW AMENDMENT OF REGISTRATION SHEET MAL CONTROL NUMBER (M DEVICE REVIEW NUMBER (S)

I!.$ // /) 4 (

/&-

LETTER /APPUCArON DATE UCENSE hUMBER(S)

CUSTOM REVIEW an unaw, m.

a54

. o. c ric ?c y,3 nbm /

CA 90 %2/

FOR SSSS USE ONLY AEVIEWER MODEL NUMBERS NUM8ER ASSGNED Y())_/ 0?/ A

~b

"^*"'7"/g/9y j,

g 7 y

" " ~

  • ^* ~ "*

TYPE OF ACTION (Indieate the number of each type) l COMMERCIAL DISTRIBUTION (FORMAL) l USE BY A SINGLE APPLICANT (CUSTOM)

SOURCE (9C)

DEVICE (9A)

SOURCE (90)

DEVICE (98)

NEW NEW NEW NEW AMENDMENT

~

AMENDMENT

~

AMENDMENT

~

AMENDMENT j NO SAFETY EVALUATION REQUIRED j LICENSING ACTION REQUIRED IF KNOWN NO NO FEES REQUIRED j OTHER (Specify)

TOTAL NUMBER OF NOTES

_.IO g,g M/,#

% /,2d' a REVIEW HOURS D IC E.NC LETTERS N

NUMDER OF DEFICIENCY CALLS FOR BILLING PURPOSES ONLY

+j NEW REG'STRATION -

_) PCODUCT INACTIVE -

NAME CHANGE ADDRESS CHANGE ADD TO BILLING REMOVE FROM BILLING l

FOR FEE USE ONLY TYPE OF FEE FEE CATEGORY 7 9A U 98 9C 90 i

AAOUNT RECElVED l

CHECK NUMBER MATANN UPDATED I

' /

AS REQUIRED a

' Yy f

' a % i fm'"

_Jgs;sgel,^Teo

= =

APPROVED BY OATE #ETURN

/

DATE V

J COMMENTS I

NRC FORM 667 (s.93) omomm.To asss

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCES PAGE1ef3 NO.:LA300S1485 DATE:

December 15,1982 Amended in Entirety SEALED SOURCE TYPE:

Industrial Radiography Eource Assembly j

MODEL:

"G" Series MANUFACTURER / DISTRIBUTOR:

Source Production and Equipment Co.,Inc.

625 Oxley Street Kenner, Louisiana 70062 H

\\

MANUFACTURER / DISTRIBUTOR:

MAXIMUM ACTIVITY _:

110 curies ISOTOPE: Cobalt-60 240 curies w

Iridium-192 1

LEAK TEST FREQUENCY _: 6 Months PRINCIPAL USE:

Indusulai Radiographv YES X _NO CUSTOM SOURCE:

k/

4 L-

m.

2-re,

I.

s

'N REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES f

SAFETY EVALUATION OF SEALED SOURCE NO. :LA-300-S-149-S -

DATE: 5/15/73 PAGE 1 OF 1 SEALED SOURCE TYPE:

Beta Sources for Gauging and Calibration MODEL:

BSE-1 l MANUFACTURER / DISTRIBUTOR:

Gamma Industries A division of Nuclear Systems, Inc.

ISOTOPE:

MAXIMUM ACTIVITY:

Antimony-125 5 mil 11 curies Bismuth-210 5 millicuries

. Calcium-45 5 millicuries

{y'T Cerium-141 10 millicuries l

/

Cerium-Praseodymium-144 500 millicuries Cesium-1347 100 millicuries Cesium-Barium-137 500 millicuries'.

Chlorine-36 1 r..illicurie Cobalt-60 100 millicuries Mercury-203 100 millicuries

-Nickel-63 5 millicuries Niobium-95 5 millicuries Phosphorus-32 25 millicuries l

Promethium-147 25 millicuries l

Strontium-89 10 millicurues l

Strontium-Yttrium-90 500 millicuries

-Sulphur-~35-10 millicuries Thallium-204-25 millicuries Polonium-Bismuth-Lead 25 millicuries (Radium DEF) l..

L

. LEAK TEST FREOUENCY:

6 Months l

l l

PRINCIPAL USE:

(T) Other

~

-n M-CUSTOM DEVICE:

YES X

NO 4

4-.

m

m...

... _. ~.. _ _ _. _ - _.. _ _.. - _ _ _. -

\\

REGISTRY.0F RADI0 ACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE No. 'LA300S151S DATE: May 5, 1985 PAGE 1 of 5 SEALED SOURCE TYPE:

Industrial Radiography Source Assembly

!~

MODEL:

IN" Series MANUFACTURER / DISTRIBUTOR: Gammaa Industries l

2255 Ted Dunham Avenue l

Baton Rouge, Louisiana 70802 L

l

[

- ISOTOPE: Iridium-192 MAXIMUM ACTIVITY:

120 Curies LEAK TEST FREQUENCY:

6 months s

PRINCIPAL USE:

Industrial Radiography CUSTOM SOURCE:

YES X NC.

I 4

i i-g yw g rt-yg--

ese+nr.

7-fr 4

g-

,.4 vgp,g.nge, 9

+-%.-

g-7y,,..

,----g%wy.

--w,-


a

>.w-2-w e

e g,-

REGISTRY OF RADIOACTIVE SEALED SOUhCES AND DEVICES 4

SAFETY EVALUATION OF SEALED SOURCE

'J go,t - LA-0300-S-155-S -

DATE: 6/15/89 PAGE 1 OF 1 I ~

SEALED __ SOURCE TYPE:

Unknown MODE Td.

VD, VD (HP)

MANUFACTURER / DISTRIBUTOR:

Gamma Industries A Division of Nuclear Systems, Inc.

I ISOTOPE:

MAXIMUM ACTIVITY:

Americium-241' 2 curies i

Iridium-192 100 curies

'AM Any Beta Gamma Emmiter 20 curies LEAK TEST FREOUENCY:

6 Months PRINCIPAL USS;.

(T) Other gy,STOM DEVICE:

YES X

NO 7<~g f

I

\\

'li

- = -

SEP 141998 MEMORANDUM TO:

Sandra Kimberley, License Fee Analyst Office of the Chief Financial Officer FROM:

Seung J. Lee, Mechanical Engineer Material Safety Branch Division of Industrial and Medical Nuclear Safety, NMSS

SUBJECT:

INACTIVE STATUS: GAMMA INDUSTRIES, INC.

ASSIGNMENT NUMBERS 98-44, 984 5, 98-64, & 98-65 We have converted the registration certificates identified in column 1 of the table in the attachment to inactive status and have assigned them the new registration certificate numbers identified in column 2 of the table. If you have any questions, please contact me at 415-5787 or Mr. John Lubinski at 415-7868.

Attachment:

As stated 1

Distribution:

IMNS r/f SSD-98-44, -45, -64, -65 NE01 Registration Certificates listed in Attachment DOCUMENT NAME: C:\\ FILES \\SSDS\\ GAMMA 2.IND Ts receive a copy of this document, indicate in the bos:

"C* = Cophithout attaC5 ment / enclosure "E' = Copy with attachment / enclosure "N* = No copy OFF!CE IMSB IMSB j d ld l

NAME Slee/jl

(//

JLubinsk DATE 09/pf98 09//q/98 OFFICIAL RECORD COPY

'Y

._._.m_.

'a:

s

.i -

I GAMMA INDUSTRY, INC. REGISTRATION CERTIFICATES 1

OLD NUMBER.

NEW NUMBER 1

i NR-300-S-101-U -

NR-300-S-836-S LA-300-S-102-U NR-300-S-837-S LA-300-D-103-U NR-300-D-838-S LA-300-D-104-U NR-300-D-839-S LA-300-D-105-U NR-300-D-840-S LA-300-D-106-U NR-300-D-841-S LA-300-S-107-U NR-300-S-842-S LA-300-D-108-U NR-300-D-843-S LA-300-D-109-U NR-300-D-844-S LA-300-D-110-U NR-300-D-845-S LA-300-D-111-U NR-300-D-846-S LA-300-D-112-U NR-300-D-847-S LA-300-D-113 U NR-300-D-848-S LA-300-D-114-U NR-300-D-849-S LA-300-D-115-U NR-300-D-850-S LA-300-D-147-S NR-300-D-879-S LA-300-S-148-S NR-300-S-880-S LA-300-S-149-S NR-300-S-881-S LA-300-D-150-8 NR-300-D-882-S LA-300-S-151-S NR-300-S-883-S LA-300-D-152-S NR-300-D-884-S LA-300-D-153-S NR-300-D-885-S LA-300-D-154-S NR-300-D-886-S LA-300-S-155-S NR-300-S-887-S I

ATTACHMENT c

... -