ML20151Z740

From kanterella
Jump to navigation Jump to search
Registry of Radioactive Sealed Sources & Devices,Safety Evaluation of Radiographic Exposure Device for Model Century Universal.Certificate:NR-300-D-846-S
ML20151Z740
Person / Time
Issue date: 09/14/1998
From: Michele Burgess, John Lubinski
NRC
To:
References
SSD, NUDOCS 9809220102
Download: ML20151Z740 (4)


Text

.

i I

. REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY. EVALUATION OF DEVICE

{

l 4

NO.: NR-300-D-846-S

.DATE:

g[p } 4 jggg PAGE 1 OF 4 DEVICE TYPE:

Radiographic Exposure Device MODEL:

Century S. Universal MANUFACTURER / DISTRIBUTOR:

- Gamma Industries, Inc.

P.O. Box 2543 Baton Rouge, LA 70821 SEAT.RD SOURCE MODEL DESIGNATION:

Gamma Industries S-16 ISOTOPE:

MAXIMUM ACTIVITY:

j Iridium-192 100 curies (3 7 TBq)

Cobalt-60 100 millicuries (3. 7 GBq)

-I

' Depleted Uranium Shielding, 12 kilograms (27 lb) l i

j

. T.FAK TEST FREOUENCY 6 months i

i PRINCIPAL USE:

(A) Industrial Radiography l

CUSTOM DEVICE:

YES X

NO 9909220102 990914 y

PDR RC

.'SSD.

PDR

$'t

,w.

)

l, REGIS"RY.OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE j

i l

l i

NO.: NR-300-D-846-S DATE:

PAGE 2 OF 4 H

ggp g 4

' DEVICE TYPEi

' Radiographic' Exposure Device DESCRIPTION:

The device consists of a. depleted uranium shield and a polyurethane filler enclosed in a 1/8" (3.18 mm) steel case consisting of a~right circular cylinder and two cast 1/4"

. ( 6. 3 5 mm) _end pieces.

The assembly is secured by.heliarc

welding.

The bottom of the device has'four ears located in the 0

' corners and a hole through each ear which is used for securing the device to a pipe.

A zircaloy "S"

tube extends through the device's shielding mass.

At one end is a lock' box through which the source pigtail cable andfmale half of the quick disconnect-connect. connector protrude.

The lock box is designed such that the source pigtail.cannot be

^

pulled' backwards to the lock-box to expose the source when j

connecting the drive cable female half of the connector to the i

source pigtail.

A plunger type lock secures the assembly against movemelia in the zircaloy "S"_ tube.

The lock' box is located at

'the' top of the' device. 'At the bottom ' of the device, a source

' conduit.is' attached to a fitting at thefopposite end of the "S"

tube byLa spring loaded quick disconnect-connect arrangement after removing a protective screw cap.

The source guide tube may beLof-transparent PVC'or'the more common' opaque: neoprene coated j

steel-type.

i The-depleted uranium' shield (approximately 27/ pounds [12 kg] ) is secured in position-by the two cast' steel end pieces and is cushioned'on its' circumference within the device by polyurethane.

JA teleflex' drive cable. arrangement with a hand crank is provided for moving the source between the exposed and. shielded positions j

from a remote location.

w v

~

v

i r'

(

i t

REGISTRY'OF RADIOACTIVE SEALED SOURCES AND DEVICES

(

. SAFETY EVALUT.T?m3 OF DEVICE l

NO.: NR-300-D-846-S DATE:

Epl4;ggg PAGE 3 OF 4 I

DEVICE TYPEr Radiographic Exposure Device i

DESCRIPTION (Cont'd)-

)

i A collimator can also be attached to the end of the zircaloy "C"

tube _by.the means of a threaded area attached to the outer case

-of the device.

The collimator is screwed to a threaded. portion

~around the quick' disconnect-connector. 'This arrangement permits the' device to be,usedias a Pipeliner in that the-source is never

-in a completely exposed position.

The source'only moves an approximate distance of 6" (15. 24. cm).

The'collimator is 2-3/8" i

n (6.03 cm) long by-2" '(5.08 cm) J in diameter and has a cavity of

'^

1-3/8 " - (3.4 9 cm) deep which is located 0.1;3" (7.62 mm) offset from the center of the collimator.

This allows la (2.54 cm) of

~

tungsten on both-the top and front of'the collimator.

The~ cavity is'0.600" (15.24 mm) inJdiameter and'is tapped with. number 14 national fineLthread'_to a depth of.3/8" (9.53 mm).

A window is cut in'the collimator all the!way through to'the cavity and a butt plate of' stainless ~ steel',.0.025" ( 0. 64 ami) thick is cut and fit in the window.

1Thefoutside dimensions of the device-are.5-1/2" (13.97 cm) in diameter:by 7-3/8" (18.73 cm) in height.

LABELING:

L The c'

.ce,is labeled the same as the Gamma Century.

' EXTERNAL RADIATION LEVELS

=The' radiation levels are the same as a Gamma Century.

1

t REGISTRY OF RADIOACTIVE. SEALED SOURCES'AND DEVICES SAFETY EVALUATION OF DEVICE NO.: NR-300-D-046-S DATE!

g p j 4 ]ggg PAGE 4 OF 4 DEVICE TYPE:

Radiographic Exposure Device ~

LIMITATIONS AND/OR OTHER CONSIDERATIONS OF'USE:

The same consideration as for a Gamma Century.

SAFETY ANALYSIS

SUMMARY

.The Model Century S.. Universal device is no longer manufactured

orLdistributed by Gamma Industries,.Inc.'and Gamma Industries,

-Inc. is no longer in business.

Therefore, the registration certificate is being converted to an inactive registration

. certificate.

.The device was originally approved for licensing purposes ay the Louisiana Division of Radiation Control.

NRC attempted'to obtain copies of all information submitted by the registrant in support of the evaluation.

However, NRC could not locate all the

(

'information.

Therefore, no safety evaluation.of the device was performed as part of the conversion of the certificate to inactive status.

l L

i-l ISSUING AGENCYL i

I' U.S. Nuclear Regulatory Commission l'

E P I 4 1998 f'I Date:

Reviewer:

[i/

John W.

Lubinski SEP 141998 Date:

Concurrence: 2A4 M #/%.

c.~ -1 Michele L.

Burgess i

i y

e

PAGE1 NRC FOFM 567 U. S. NUCLEAR REGutATORY COMMISSION 1

REQUEST FOR A SEALED SOURCE OR DEVICE EVALUATION INSTRUCT (ONS: Send this request AND a copy of all related letters /appiMions T.nd drawings to: The Sealed Source Safety Section, AITN: Chief, OWFN Mail Stop 6 H3. Change the License Tracking System milestone to 19 and assign to reviewer code I-5.

NOTE: Retain a copy of this request with the appilcation and tieckground flies.

REQtf STER REGION / LOCATION:

ll ll R lil IV RV C HQ R LFDCB TELEPHONE NUMBER DATE TYPE OF ACTION REQUESTED (Check as approntate)

APPLIC E

SOURCE REVIEW AMENDMENT OF

_. /'J1776_

[/V /5

..I/y.

REGISTRATION SHEET

/

MAIL CONTRdL NUMBER (S)

/

DEVICE REVIEW NUMBEMS)

LETTER /

TION ATE LICENSE NUMBER (S)

CUSTOM REVIEW f

f c"*"

' p o. box 2545 fxt k b cp,u 9 7o w FOR SSSS USE ONLY "I 7 3 LS 'mv 98<45~

REVIEWER NUMBER ASSIGNED DATE RECOVED DATE ASSONED DATE TO FEES TYPE (Y ACTION (Ind6 cab N number of eat.h type) l COMMERCIAL DISTRIBUTION (FORMAL) l USE BY A NfhyF PUCANT(CUSTOM)

SOURCE (9C)

DEVICE (9A)

SOURCC JeD1 I

DEVICE (98)

NEW NEW NEW NEW

] AMENDMENT

, AMENDMENT AMENDMENT AMENDMENT

,_j NO SAFETY EVALUATION REQUIRED d

LICENSING ACTION REQUIRED IF KNOWN NO NO FEES REQUIRED t

j OTHER (Spedy) l TOTAL NUMBER OF NOTES i

REVIEW HOURS Mb h

l NUMBER OF g M gi) / A *(NM DEFICIENCY LETTERS l

NUMBER OF V

l DEFICIENCY CALLS FOR BILLING PURPO6ES ONLY q

d j NEW REGl!TRATION-

,_j PRODUCT INACTIVE -

NAME CHANGE ADDRESS CHANGE ADD TO BILLING REMOVE FROM BILLING h

FOR FEE USE ONLY TYPE OF FEE FEE CATEGORY f

1

] 9A U 98

~

90 9D AMOUNT RECOVED CHECK NUMBER MATANN UPDATED

{

4

- AS REQUIRED gje g g sw

_JggYS"I$

,u

-TE Rn

-,E D\\

I)

LA OScoDn D3U,+5,L JSf4 ll,W IS 3 h.

norm.or m

&W

. 8 W _ j '2 6 8 9 Y ' Y '

l s

o l

4' l 'o

$EP 141938 1

MEMORANDUM TO:

Sandra Kimberley, License Fee Analyst Office of the Chief Financial Officer FROM:

Seung J. Lee, Mechanical Engineer Material Safety Branch Division of Industrial and Medical Nuclear Safety, NMSS

SUBJECT:

INACTIVE STATUS: GAMMA INDUSTRIES, INC.

ASSIGNMENT NUMBERS 98-44, 98-45, 98-64, & 98-65 We have converted the registration certificates identified in column 1 of the table in the attachment to inactive status and have assigned them the new registration certificate numbers identified in column 2 of the table. If you have any questions, please contact me at 415-5787 or Mr. John Lubinski at 415-7868.

Attachment:

' As stated Distribution:

IMNS r/f SSD-98-44, -45, -64, -65 NE01 Registration Certificates listed in Attachment i

DOCUMENT NAME: C:\\ FILES \\SSDS\\ GAMMA 2.IND T.,.c.6

. copy or ini. a.curn.nt. ino c.t. in in. no : c - copeitnout.ti. cam.nti..,cio.ur.

e - copy itn.ti :nm.nizincio.or.

u - no copy OFFICE IMSB IMSB j Q d

NAME Slee/jl

(//

JLubinsilj DATE 09////198 09//4/98

'A OFFICIAL RECORD COPY l

l

~

A t'

e GAMMA INDUSTRY, INC, REGISTRATION CERTIFICATES l

l OLD NUMBER NEW NUMBER NR-300-S-101-U NR-300-S-836-S

)

LA-300-S-102-U NR-300-S-837-S i

LA-300-D-103-U NR-300-D-838-S LA-300-D-104-U NR-300-D-839-S LA-300-D-105-U NR-300-D-840-S LA-300-D-106-U NR-300-D-841-S LA-300-S-107-U NR-300-S-842-S l

LA-300-D-108-U NR-300-D-843-S l

LA-300-D-109-U NR-300-D-844-S LA-300-D-110-U f JR-300-D-845-S LA-300-D-111-U NR-300-D-846-S t

LA-300-D-112-U NR-300-D-847-S LA-300-D-113-U NR-300-D-848-S LA-300-D-114-U NR-300-D-849-S LA-300-D-115-U NR-300-D-850-S LA-300-D-147-S NR-300-D-879-S LA-300-S-148-S NR-300-S-880-S i

LA-300-S-149-S NR-300-S-881-S i

LA-300-D-150-S NR-300-D-882-S LA-300-S-151-S NR-300-S-883-S LA-300-D-152-S NR-300-D-884-S LA-300-D-153-S NR-300-D-885-S LA-300-D-154-S NR-300-D-886-S LA-300-S-155-S NR-300-S-887-S i

ATTACHMENT L

-