ML20151Z681
ML20151Z681 | |
Person / Time | |
---|---|
Issue date: | 09/14/1998 |
From: | Michele Burgess, John Lubinski NRC |
To: | |
Shared Package | |
ML20151Z639 | List: |
References | |
SSD, NUDOCS 9809220072 | |
Download: ML20151Z681 (3) | |
Text
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE HQ1 NR-300-S-836-S DATE: $[p ] 4 Jggg PAGE 1 OF 3 I SOURCE TYPE: Sealed Source MODEL' P-10 -
t MANUFACTURER / DISTRIBUTOR: Gamma Industries, Inc.
P.O. Box 2543 Baton Rouge, LA 70821 i
)
i i
. ISOTOPE:
. MAXIMUM ACTIVITY: #
t i
')
TRAK TEST FREOUENCY: 6 months >
PRINCIPAL USE: (A) Industrial Radiography i
i CUSTOM SOURCE: YES X NO l
9e')9220072 990914 PDR RC
- SSD PDR h
._ 3 i
e r *
~ . . , . _ , _ . _.m - . _...,_ _._ . .
~
? . ( ~~
i F . ..- .
' REGISTRY OF RADIOACTIVE SEALED SOURCES AND-DEVICES !
SAFETY-EVALUATION OF SEALED SOURCE l
.; HQ1: NR-300-S-836-S 'DATE, .SEP 141938 PAGE 2 OF 3 s..
l SOURCE-TYPE:
Sealed Source .l t
a
' DESCRIPTION:
i i
Source-to'be used in Curtiss-Wright' Corporation's " Puff Camera" j for' industrial. radiography. !
i- 4
' Source consists of two' separate sealed source' capsules which are 1 individually welded. Inner capsule has wall thickness of 25 mils i and outer capsule has an"85 mils wall. Sources are polished and
' edgesTrounded. i LABELING:
J
., ' Labeled with serial number, isotope and manufacturer's trade- l' mark.
LIMITATIONS-AND/OR'OTHER CONSIDERATIONS OF USEE
- Capsule used only in."Puffa camera.- i I
- SAFETY ANALYSIS
SUMMARY
' The Model P-10 source is:no. longer manufactured or distributed by Gamma Industries, Inc. and Gamma Industries,.Inc. is no longer in .;
- business. Therefore, the registration certificate is being ;
converted to an inactive registration certificate. l t
i l
1 o
i i
, 3, .
l l'
REGISTRY OF-RADIOACTIVE SEALED SOURCES AND DEVICES ,
SAFETY EVALUATION OF SEALED SOURCE L
{
HQL NR-300-S-836-S_. .DATE: IIP 1 4 j$$$ PAGE 3 OF 3 l I
j
' SOURCE TYPE: Sealed Source 1 1
SAFETY' ANALYSIS
SUMMARY
'(Cont'd)- .
i The source:was originally approved for licensing purposes on March 18, 1960, by the Atomic Energy Commission. NRC attempted ;i to obtain copies of all information submitted by the registrant' ]'
in support of'the evaluation. However,'NRC could=not locate all.
the information. Therefore, no safety evaluation of the source was performed as_part of the conversion of the certificate to inactive status.
ISSUING AGENCY
/ =
U.S. Nuclear Regulatory Commission '
/
A
'Date: Reviewer: /
John W.~Lubinski l Date: SEP 141988 Concurrence: h4 6 M r - J Michele~L. Burgess I
L
\ :
r~
,:. }
.-,