ML20151Z405

From kanterella
Jump to navigation Jump to search
Submits Info to Support Licensee Request Dtd 980625,as Per Request of Felsher on NRC Behalf
ML20151Z405
Person / Time
Site: 07001201
Issue date: 09/14/1998
From: Allsep T
FRAMATOME COGEMA FUELS (FORMERLY B&W FUEL CO.)
To: Lamastra M
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM), NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
NUDOCS 9809210328
Download: ML20151Z405 (1)


Text

-

~m.

l e,*

j 1

4.,

j f M WN.9td s a Auto u a C (lMA S M E lA M E i

September 14,1998 Director, OfHee of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission

'ATfN: Document Control Desk i

Washington D.C.,20555

Reference:

Docket 70-1201, SNM-1168

Dear Mr. Lamastra,

As per the request of Mr. Felsher on your behalf, the following information is provided to support our request dated June 25,1998.

1)

The definition of a Non-production Facility as defined in 10CFR50.2 is ".. facilities in which the only gccial nuclear materials contained in the irradiated material to be processed are uranium in the isotope U-235 and plutonium producod by the irraliation, if the material processed contains not more diat 104 grams of plutonium per gram of U 235."

Assuming a worst case scenario of 100% Pu-239 and a minimum enrichment of 2.5% U-235,50 Bq/gran U material would contain less than 104 grams of plutonium per gram of U-235.

2)

Personnel exposures resulting from an increase in the limit for transuranic isotopes from 3.3 By per gram of uranium to 50 Bq per gram of uranium would be insignificant froin both an individual and i

a collective dose viewpoint. This conclusion is based on; l) the small amount of transuranic i -

isotopes contained la the material (less than 1 ppm); 2) the small increase in specilic activity (less than 0.013 percent); and 3) the gamma ray energies associated with these isotopes at $hese concentrations.

Should you require further information, phase contact me at (804) 832-5202, or Mr. C.F. Sanders at (804)832 5216.

Thank you for your time and efforts

/

Sincerely, p

Framatome Cogerna Fuels M

e Timothy V. Al. y

/L/

Acting Manager, Safety & Licensing cc:

htr.htichael A.Iamastra United States Nuclear Regulatory Commission Office of Nuclear Listerials safety & Safeguards i.

Division of Fuel Cycle Safety & Safeguards

(

Ucensing Ilranch, Ucensing Section 2 l-htail Stop T8D12

(

j Two White Gmt North l

It555 Rockville Pike l.

Rockville htD20852-2738 I

9809210328 980914

~9 PDR ADOCK 07001201 C

pm

,a