UNITED STATES 8

NUCLEAR REGULATORY COMMISSION o

D j

WASHINGTON, D. C. 20555

~s*****/

JAN 2 91986 Docket Nos.: 50-482

- 3 and 50-483

e; -

~.. :-

Mr. James 0. Cermak Technical Director, SNUPPS Utilities 5 Choke Cherry Road Rockville, Maryland 20850

Dear Mr. Cemak:

j.

Subject:

Request for Withholding Information from Public Disclosure By your application and affidavit dated January 8,1986, you submitted

. " Steam Generator Single Tube Rupture Analysis for SNUPPS Plants - Callaway

' is -

and Wolf Creek" and requested that it be withheld from public disclosure

'.2 pursuant to 10 CFR 2.790.

You stated that the submitted information should be considered exempt from mandatory public disclosure for the following reasons:

1.

The information sought to be withheld from public disclosure is owned and has been held in confidence by the SNUPPS Utilities.

The information is of a type customarily held in confidence by other organizations and not customarily disclosed to the public.

2.

The information is being transmitted to the Comission in confidence and, under the provisions of 10 CFR Section 2.790, it is to be received in confidence by the Commission.

.I 3.

The information sought to be protected is not available in public sources to the best of our knowledge and belief.

4.

The proprietary information sought to be withheld in this submittal is that which is appropriately marked in " Steam Generator Single-Tube Rupture Analysis for SNUPPS Plants - Callaway and Wolf Creek",

dated December 1985.

The subject information could only be duplicated by competitors if they were to invest time and effort equivalent to that invested by the SNVPPS-Utilities provided they have the requisite talent and experience.

c.

-t.

Public disclosure of this information is likely to cause substan~ti,a1 harm to the competitive position of the SNUPPS Utilities because it would' simplify design and evaluation tasks without requiring a commensurate investment of time and effort, i

g Ap KOO D

P

Mr. D. F. Schnell SNUPPS Union Electric Company Mr. Glenn L. Koester Kansas Gas and Electric Company

- }..

'I

  • ?"

cc:

Gerald Charnoff, Esq.

Jay Silberg, Esq.

Thomas A. Baxter, Esq.

Shaw, Pittman, Potts & Trowbridge

- Shaw, Pittman, Potts & Trowbridge 1800 M Street, NW 1800 M Street, NW Washington, D.C.

20036 Washington, D.C.

20036 Mr. Donald W. Capone '

Kansas City Power & Light Company Manager - Nuclear Engineering ATTN: Mr. D. T. McPhee Union Electric Company Vice President - Production P. O. Box 149 1330 Baltimore Avenue St. Louis, Missouri 63166 Kansas City, Missouri 64141 TediScully, Director Special Projects Division Mr. Nicholas A. Petrick Kansas Corporation Comission Executive Director, SNUPPS State Office Building, 4th Floor 5 Choke Cherry Road t.

Y Topeka, Kansas 66612 Rockville, Maryland 20850 Mr. J. E. Birk Regional Administrator, Region III Assistant to the General Counsel U.S. Nuclear Regu?atory Comission I

Union Electric Company 799 Roosevelt Road St. Louis, Missouri 63166 Glen Ellyn, Illinois 60137 Resident Inspector / Wolf Creek NPS Regional Administrator, Region IV c/o U.S. Nuclear Regulatory Comission U.S. Nuclear Regulatory Commission P. O. Box 311 611 Ryan Plaza Drive, Suite 1000 Burlington, Kansas 66839 Arlington, Texas 76011 Mr. Michael C. Keener Mr. Allan Mee State Corporation Comission Project Coordinator A

State of Kansas Kansas Electric Power Cooperative Fourth Floor, State Office Building P. O. Box 4877 Topeka, Kansas 66612 Gage Center Station

-Topeka, Kansas 66604 Resident inspector U.S. Nuclear Regulatory Comission John H. Simpson, Esq.

RR #1 Attorney for Intervenors Steedman, Missouri 65077 4350 Johnson Drive, Suite 120 Shawnee Mission, Kansas 66205 C. Edward Peterson, Esq.

--f-Legal Division Kansas Ccrporation Comission Fourth Floor a t.

State Office Building

[-

Topeka, Kansas 66612

Union Electric Company SNUPPS Kansas Gas and Electric Company cc:

Brian P. Cassidy, Regional Counsel

, r..

FEMA, Region I J. W. McCormack POCH I e: -

Boston, Massachusetts 02109

, y.

Mr. Ronald A. Kucera, Deputy Director Department of' Natural Resources P. O. Box 1776 Jefferson City, Missouri 65102 Chris R. Rogers, P.E.

Manager, Electric Department Missouri Public Service Commission e-P. O. Box 360 Jefferson City, Missouri 65102 Mr. Gerald Allen Public Health Physicist Bureau of Air Quality and if Radiation Control 2,

Division of Environment Kansas Dept of Health & Environment Forbes Field Building 321 Topeka, Kansas 66620 hbe m

J e

e e

~ [.

]

JAN 2 91986 Mr. James 0. Cermak We have. reviewed your application and the material based on the requirements and criteria of 10 CFR 2.790 and on the basis of your statements, have deter-mined that the submitted information sought to be withheld contains trade secrets or proprietary commercial information.

Therefore, the version of the submitted information marked as proprietary, will be withheld from public disclosure pursuant to 10 CFR 2.790(b)(5) and Section 103(b) of. the Atomic Energy Act of 1954, as amended.

Withholding from public inspection s' hall not affect the right, if any, of per-sons properly and directly concerned to inspect the documents.

If the need arises, we may send copies of this information to our consultants working in this area. We will, of course, insure that the consultants have signed the appropriate agreements for handling proprietary ~information.

If the basis for withholding this information from public inspection should change in the future such that the information could then be made available for public-inspection, you should promptly notify the NRC. You should also understand that the NRC may have cause to review this determination in the future, such as if the scope of a Freedom of Information Act request includes

-your information.

In all review situations, if the NRC makes a determination adverse to the above, you will be notified in advance of any public disclosure.

Sincerely,

. orietal dWd*

p. thod D

~

/

8. J. Youngblood, Director PWR Pro,iect Directorate #4 Division of PWR Licensing-A, NRR cc: See next page DISTRIBUTION:.

NSIL EShomaker, OELD TAlexion Docket File;./

C=PDR PRC System MDuncan Local PDR PWR#4 R/F P0'Connor

[

D.S # 4 OE/h PWR#,4:hWR-A PWR#4:DPWR-A.

PWR#4:DPWR-A MDurid,an:kab P0'Connor EhAnaker BJYoungblood Old1/86 01/2.q /86 01/$ /86 01/y /86 4

/