ML20151X050

From kanterella
Jump to navigation Jump to search

Forwards Safety Evaluation for Relief Request VR-63 to Pump & Valve Inservice Testing Program.Alternative Testing Proposed in Subj Relief Request Authorized,Per 970214 Request
ML20151X050
Person / Time
Site: Fermi DTE Energy icon.png
Issue date: 09/11/1998
From: Carpenter C
NRC (Affiliation Not Assigned)
To: Gipson D
DETROIT EDISON CO.
Shared Package
ML20151X052 List:
References
TAC-M98009, NUDOCS 9809160236
Download: ML20151X050 (4)


Text

..

I September 11, 1998 Mr. Douglas R. Gipson Senior Vice President Nuclear Generation Detroit Edison Company 6400 North Dixie Highway Newport, Michigan 4816S

SUBJECT:

FERMI 2 - SAFETY EVALUATION FOR RELIEF REQUEST VR-63 TO THE PUMP AND VALVE INSERVICE TESTING PROGRAM (TAC NO. M98009)

Dear Mr. Gipson:

On February 14,1997, you submitted relief requests VR-63 and VR-64, requesting relief from certain inservice testing requirements of the American Society of Mechanical Engineers Code,Section XI. The staff reviewed the submittal and sent a request for additional information (RAl) to you in a letter dated August 27,1997. You responded to the staff 's RAI in a letter dated i

April 30,1998, withdrawing relief request VR-64 and providing additional justification for relief request VR-63. The staff has completed its review of the relief request VR-63 as discussed in l

the enclosed safety evaluation. The alternative testing proposed in relief request VR-63 is authorized pursuant to 10 CFR 50.55a(a)(3)(ii) on the basis that the proposed testing provides j

reasonable assurance of operational readiness and the imposition of Code requirements would i

result in hardship without a compensating increase in the level of quality or safety.

l if you have any questions regarding this issue, please contact me at (301) 415-2828.

Sincerely, Original signed by:

Cynthia A. Carpenter, Director i

Project Directorate Ill-1 l

Division of Reactor Projects -Ill/IV Office of Nuclear Reactor Regulation

Enclosure:

As stated Docket No. 50-341 l

cc w/ encl: See next page

.I

$ n7,c '5 NC l l DISTRIBUTION:

i)

Docket File PD3-1 R/F OGC SEDB (TLH3)

PUBLIC THiltz ACRS BBurgess, Rlli EAdensam (EGA1)

GHill (2)

JHuang DOCUMENT NAME: G:\\WPDOCS\\ FERMI \\FE-98009.RLF *No major changes to the SE

    • Sto previous concurrence l

Ta receive a copy of this document, Indicate in the box: "C" = Copy without attachment / enclosure "E" = Cop'r with attachment / enclosure "N" = No copy OFFICE PM:PD31 E

LA:PD31

]E SC:EMEB*

E OGC**

D:FD31 E

NAME Al(ugler @t CJamerson 61/

DTerao MYoung CACarpentert&

DATE 09/ lo /98 "

09/10 /98

[/

08/11/98 09/10/98 4 //()/98 QFFICIAL RECORD COPY pr'iB8n 388%2 NRC RLE CENTEB COPY 1

September 11, 1998 Mr. Douglas R. Gipson Senior Vice President Nuclear Generation Detroit Edison Company 6400 North Dixie Highway Newport, Michigan 48166

SUBJECT:

FERMI 2 - SAFETY EVALUATION FOR RELIEF REQUEST VR-63 TO THE PUMP AND VALVE INSERVICE TESTING PROGRAM (TAC NO. M98009)

Dear Mr. Gipson:

On February 14,1997, you submitted relief requests VR-63 and VR-64, requesting relief from certain inservice testing requirements of the American Society of Mechanical Engineers Code,Section XI. The staff reviewed the submittal and sent a request for additionalinformation (RAl) to you in a letter dated August 27,1997. You responded to the staff 's RAI in a letter dated April 30,1998, withdrawing relief request VR-64 and providing additional justification for relief request VR-63. The staff has completed its review of the relief request VR-63 as discussed in the en losed safety evaluation. The alternative testing proposed in relief request VR-63 is authorized pursuant to 10 CFR 50.55a(a)(3)(ii) on the basis that the proposed testing provides reasonable assurance of operational readiness and the imposition of Code requirements would result in hardship without a compensating increase in the level of quality or safety.

If you have any questions regarding this issue, please contact me at (301) 415-2828.

Sincerely, Original signed by:

Cynthia A. Carpenter, Director Project Directorate lil-1 Division of Reactor Projects -Ill/IV Office of Nuclear Reactor Regulation Enclosaa: As stated Docket No. 50-341 cc w/ encl: See next page DISTRIBUTION:

Docket File PD3-1 R/F OGC SEDB (TLH3)

PUBLIC THiltz ACRS BBurgess, Rlli EAdensam (EGA1)

GHill(2)

JHuang DOCUMENT NAME: G:\\WPDOCS\\cERMI\\FE-98009.RLF *No major changes to the SE

    • Sta previous concurrence t.

c.w.. eopy or inis oocum.nt, indic.i. in in. bon: c. copy weout en cnm.nu.ncio.ur. r. cop, we en. cam.nvenciosur. N No copy OFFICE PM:PD31 lE LA:PD31 JE SC:EMEB*

E OGC**

l D:PD31 E

NAME AKugler OF CJamerson W DTerao MYoung CACarpenterC6 DATE 09/ f o /98 "

09/10 /98

[]

08/11/98 09/10/98 4 //D/98 i

OFFICIAL RECORD COPY

-- _ - - ~.

p etouq

["

k UNITED STATES s

g NUCLEAR REGULATORY COMMISSION 2

WASHINGTON, D.C. 2004 5 0001

\\,...../

September 11, 1998 Mr. Douglas R. Gipson Senior Vice President Nuclear Generation Detroit Edison Company 6400 North Dixie Highway Newport, Michigan 48166

SUBJECT:

FERMI 2 - SAFETY EVALUATION FOR RELIEF REQUEST VR-63 TO THE PUMP AND VALVE INSERVICE TESTING PROGRAM (TAC NO. M98009)

Dear Mr. Gipson:

On February 14,1997, you submitted relief requests VR-63 and VR-64, requesting relief from certain inservice testing requirements of the American Society of Mechanical Engineers Code,Section XI. The staff reviewed the submittal and sent a request for additionalinformation (RAl) to you in a letter dated August 27,1997. You responded to the staff 's RAI in a letter dated April 30,1998, withdrawing relief request VR-64 and providing additional justification for relief request VR-63. The staff has completed its review of the relief request VR-63 as discussed in the enclosed safety evaluation. The alternative testing proposed in relief request VR-63 is authorized pursuant to *0 CFR 50.55a(a)(3)(ii) on the basis that the proposed testing provides reasonable assurance of operational readiness and the imposition of Code requirements would result in hardship without a compensating increase in the level of quality or safety.

If you have any questions regarding this issue, please contact me at (301) 415-2828.

Sincerely, C nthia A. Carpenter, Director Project Directorate lil-1 Division of Reactor Projects -lil/IV Office of Nuclear Reactor Regulation

Enclosure:

A3 stated Docket No. 50-341 cc w/ encl: See next page l

l l

. =

6 Mr. Douglas R. Gipson Fermi 2 Detroit Edison Company cc:

John Flynn, Esquire Senior Attomey Detroit Edison Company 2000 Second Avenue Detroit, Michigan 48226 j

Drinking Water and Radiological j

Protection Division Michigan Department of Environmental Quality 3423 N. Martin Luther King Jr Blvd P. O. Box 30630 CPH Mailroom Lansing, Michigan 48909-8130 U.S. Nuclear Regulatory Commission Resident inspector's Office 6450 W. Dixie Highway Newport, Michigan 48166 Monroe County Emergency Management Division 963 South Raisinville Monroe, Michigan 48161 Regional Administrator, Region 111 U.S. Nuclear Regulatory Commission 801 Warrenville Road Lisle, Illinois 60532-4351 Norman K. Peterson Director, Nuclear Licensing Detroit Edison Company Fermi 2 - 280 TAC 6400 North Dixie Highway Newport, Michigan 48166 August 1997

.