U.S. NUCLEAR REGULATORY. COMMISSION REGION I Report No. 70-371/88-04 Docket No'.70-371

~ '

License No. SNM-368 Safeguards Group 1 Licensee: UNC Naval Products Division of-UNC Rssources, Inc.  !

67 Sandy Desert Road i Uncasville, Connecticut 06382 Facility Name: UNC Naval Products Inspection At: Uncasville, Connecticut Inspection Condu'cted: March 21-25, 1988 -

i i

j Type of Inspection: Routine, Announc_ed Material Control and Accounting j Inspectorr: #l

  • h I/ ~// /

H. ' ulsky, Chemist f date '

J.

ssn dxt oss an . W Ra ation pecialist 4-iy-88 date Approved by: / J e v,7 a p M j V /

EJ' scFak, Chief, Effluents 7 f te l R iation Protection Section, acilities Radiological Safety and j i Safeguards Branch, DRSS I

Inspection Summary: Routine, Announced Material Control and Accounting

~

Inspection on March 21-23, 1988 (Report No. 70-371/88-04) !

i 1

! Areas Inspected: Measurement control program for special nuclear material i

1 l Results: The licensee was in compliance in the area examined during this i

]

inspection.

]

1  ;

i i

]

i l  !

i 1

8805030473 880416

! PDR ADOCK 07100371 s ,

C DCD t i

p, ..i ,

+ 1 Details

1. Individuals Contacted
  • T. Collopy, Manager,. Nuclear Material Control.  !
  • N. Grenon, Supervisor, Nuclear Material Control ,
  • M. Kelly, Statistical Specialist
  • A. Santaniello, Manager of Laboratories ,
  • S. Ververts, Supervisor, Chemistry C. Jordan, Chemistry Technician  :

T. Pitcher, Chemistry Technician  :

The inspector also interviewed other licensee personnel involved in the control and accounting of special nuclear material and chemistry.

  • present at exit interview. ,
2. Action on Previous Inspection Items [

(Closed) 86-08-02 IFI - To verify the licensee's engineering factor used for U-235 content on certain inventory items, twenty six sections from  ;

two elements, with assigned U-235 values, were sent to the New Brunswick i Laboratory (NBL) for analysis. The analysis was completed and a  :

comparison made to .he assigned U-235 values for each section. Three f sections had a delta gram U-235 discrepancy greater than 0.1 gram U-235.  ;

The licensee's Design Engineering section revised their measurement {

procedure for generating the factor and corrected the previous assigned '

. U-235 values.

i (Closed) 86-13-01 IFI - Three experimental finished fuels were sent to  ;

NBL for analysis. The analysis was completed and a comparison of results 6 and conclusions were made. l

3. 85207 - Measurement Systems Nine liquid standards with varying matrices and concentrations of uranium l were submitted to the licensee for analyses by the NRC inspectors. The i
liquid standards were prepared with normal uranium and certified by the i

! New Brunswick Laboratory (NBL) for the NRC. The uranium concentrations .

and matrices were within the normal range of the material the licensee

! routinely analyzes. .

L The inspectors observed an analyst perform a test on three of the standards using the spectrophotometric TOP 0 extraction procedure. This ,

procedure is used to analyze low level uranium concentrations found in '

. laboratory waste solutions. Analysis of the licensee's control standard, '

Which was analyzed with the NRC standards, identified a significant i

i  !

t i

-_ - _ _ _ _ _ _ _ _ _ - _ _ _ - ..~.

3 negative bias. The analysis of the NRC standards also indicated a significant negative bias. The licensee initiated an investigation into the possibility of the spectrophotometer malfunctioning because the slope of the calibration was not changed. The licensee reanalyzed one NRC standard, control and calibration samples with another spectrophotometer.

The analytical results were in agreement. The licensee sent the malfunc-tioning spectrophotometer for repair.

The inspectors also observed another analyst, using the gravimetric Davies and Gray titration, analyze the remaining six NRC standards. The analytical results of the NRC standards were in agreement, with excellent precision and accuracy. No analytical biases were identified.

4. 30703 - Exit Interview The inspector met with the licensee representatives (denoted in para-graph 1) at the conclusion of the inspection on March 25, 1988, and summarized the scope and findings of the inspection.

At no time during this inspection was written material provided to the licensee by the inspector, s