ML20151W543

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-498/88-11 & 50-499/88-11 on 880211-0331.Enforcement Conference Scheduled for Wk of 880516 to Discuss Violations Noted,Per 880427 Telcon
ML20151W543
Person / Time
Site: South Texas  
Issue date: 04/28/1988
From: Callan L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Goldberg J
HOUSTON LIGHTING & POWER CO.
Shared Package
ML20151W546 List:
References
NUDOCS 8805030423
Download: ML20151W543 (3)


See also: IR 05000498/1988011

Text

{{#Wiki_filter:g i .. . - 2 , In Reply Refer To: Dockets: 50-498/88-11 APR 2 81988 50-499/88-11 Houston Lighting &-Power Company ATTN: J. H. Goldberg Group Vice President, Nuclear P.O. Box 1700

Houston,. Texas 77001

Gentlemen: This refers to the inspection conducted by Messrs. W. F. Smith, E. A. Plettner, P.'W. Michaud, W. B. Jones, and T. Reis during the period February 11 through March 31, 1988, of activities authorized by NRC Operating License NPF-71 and Construction Permit CPPR-129 for the South Texas Project, Unit 1 and Unit 2, respectively, and to the discussion of ' , .~ :Mings with Mr. W. H. Kinsey and . other members of your staff at the conclusion of the inspection. Areas examined during the inspection included onsitt followup of events, monthly maintenance observation, licensee action on previous inspection findings, monthly surveillance observation, engineered safety teature system walkdown, operational safety verification, and startup testing observations. Within these areas, the inspection consisted of selective examination of procedures and representative records, interviews with personnel, and observations by the NRC inspectors. The inspection findings are documented in the enclosed inspection report. During this inspection, it was found that certain of your activities appear to be in violation of NRC requirements. As discussed in our telephone conversa- tion on April 27, 1988, with you, we have tentatively scheduled an enforcement conference during the week of May 16, 1988, to discuss your understanding of the apparent violations, the reasons for occurrence, and your corrective actions. We will also discuss the NRC Enforcement Policy regarding these matters, if appropriate. The NRC is particularly concerned regarding the violation that occurred February 9,1988, involving operation in Mode 3 with seven out of twelve feedwater flow transmitters out of service. The NRC considers this violation a breakdown in your system turnover and/or startup programs and may be indicative of weaknesses in your ability to ensure that safety systems are at the state of operational readiness required for the progression of operating modes approaching full power operation. You are requested to address all aspects of this concern and provide assurance that there will be no future similar incidents in either Unit 1 or Unit 2. In addition, the NRC is concerned regarding the failure to identify applicable Technical Specification Limiting Conditions for Operation and to recognize the _ _ __ LVkRI P QRP/d' C RP D: R ttnor (DR'/JP h Inith I 4fchaud Rkis BJo'nes G 1 stable LJ 3 an , 4/o/88 (q/1 1/88 V J/t1/88 / q/t1/88 I p/88 i /p /88 4 /27/88 h g/ 8805030423 880428 PDR ADOCK 05000498 l[[ i a oco . - -

Houston Lighting & Power Company -2- . proper conditions for entering and exiting Technical Specification action statements as discussed in paragraph 2.d of this report. The adequacy of the entire program for lifted leads, fuse removal, and temporary jumpers is also of concern because of the weaknesses identified in paragraph 3.d of this report. Accordingly, the circumstances of the two additional proposed violations may also be discussed during the enforcement conference. We have also examined actions you have taken with regard to previously identified inspection findings. The status of these items is identified in paragraph 4 of the enclosed report. Should you have any questions concerning this inspection, we will be pleased to discuss them with you. Sincerely, Onyinal S&ned By A.B. BEACH L. J. Callan, Director Division of Reactor Projects Enclosure: Appendix - NRC Inspection Report 50-498/88-11 cc w/ enclosure: Houston Lighting & Power Company ATTN: M. Wisenberg, Manager Nuclear Licensing P.O. Box 1700 Houston, Texas 77001 Houston Lighting & Power Company ATTN: Gerald E. Vaughn, Vice President Nuclear Operations P.O. Box 1700 Houston, Texas 77001 Central Power & Light Company ATTN: R. L. Range /R. P. Verret P.O. Box 2121 Corpus Christi, Texas 78403 City Public Service Board ATTN: R. J. Costello/M. T. Hardt P.O. Box 1771 San Antonio, Texas 78296 City of Austin ATTh: M. B. Lee /J. E. Malaski P.O. Box 1088 Austin, Texas 78767-8814 Texas Radiation Control Program Director bec: (see next page)

, 1 c. ... > . s. , ,, - . < a , . I , s. - ' ' , L t 4 +: < . - . . . . + j , , . . . .; Houston: Lighting & Power Company-- ' 3- + , . , r .. . bec to DMB-(IE01) - , ~ bcc distrib.:by RIV ' -

  • DRP

'

  • RRI-0PS-

, . R.'D. Martin, RA'

  • RRI-CONST.
  • Section Chief-(DRP/D)

RPSB-DRSS . MIS Systen .

  • RIV File;

i

  • Lisa Shea,'RM/ALF-
  • R. : Hall

i ' R. Bachmann, OGC'. D. Powers ,

  • P.~Kadambi, NRR Project Manager
  • W. F. Smith-

,

  • TSS

E. Plettner .l '

  • DRS

P. Michaud W. B.' Jones 'T. Reis , ' *w/766' l I b r T . ' , , , , , - _ _ . - . - . . . . , -- - . - . ,..- ,- -,,_.,-.., ,. ,. , - ,, . , . , . . }}