c-l2,"r'cr"

tz.n is"=

!" f=.'"

iMt;* ivi 6

Prodwels, TJ renin.1 9015.

T.len (- L One.

sanez 67723 Em BorgWarner SS Industrial Preducts 22 December 1987 Administrator, Office of Inspection and Enforcement, Region V U. S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, California 94596 Gentlemen:

This letter serves as a transmittal of a notification required by 40CFR - Part 3&+ reporting of defects and nonconformances. The attached notification reports a condition which existed r.t the Perry Nuclear a

Generat_fng_ Station in Perry, Ohio.

tf Very truly yours, G.

General Manager Los Angeles Operations GCG/ah Attach: 3 Copies of Notification cc:

Mr. F. J. Burgers, Vice President Operations Mr. E. B. Fiske Director of Engineering Mr. R. D. Ham, Manager of Quality Mr. M. Reilly, Discoverer Mr. C. P. Spiegel, Project Manager (for customer notification)

BYRON JACK 50N ' Products l

8805030230 871222

'C PDR ADOCK 05000440

{'! I S

DCD

/

kb) 10 CFR PART 21 NOTIFICATION NAME AND ADDRESS OF IHE INDIVIDUAL OR INDIVIDUALS INFORMING THE COMMISSION:

G..Godwin 2300 East Vernon Ave.

Vernon, CA 90058-0017 IDENTIFICATION OF THE FACILITY, THE ACTIVITY, OR THE BASIC COMPONENT SUPPLIED FOR SUCH FACILITY OR SUCH ACTIVITY WITHIN THE UNITED STATES WHICH FAILS TO COMPLY OR CONTAINS A DEFECT:

Cleveland Electric Illuminating Company Perry Nuclear Generating Station, Perry, Ohio IDENTIFICATION OF THE FIRM CONSTRUCTING THE FACILITY OR SUPPLYING THE BASIC COMPONENT WHICH FAILS TO COMPLY OR CONTAINS A DEFECT:

Borg-Warner Industrial Products, Inc.

Pump Division Los Angeles Operations 2300 East Vernon Avenue Vernon, CA 90058-0017 NATURE OF THE DEFECT OR FAILURE TO COMPLY AND THE SAFETY HAZARD WHICH IS CREATED OR COULD BE CREATED BY SUCH DEFECT OR FAILURE TO COMPLY:

Valve B/M No. RNU-205 is installed with an undersized motor operstor.

This valve is classified as "active" class IE and is essential to safe shutdown of the reactor for containment isolation.

CAUSE:

In review of~the Engineering Records it was discovered that 50 PSID rather than 1400 PSID was used' for sizing the motor for this valve.

This oversight was caused by the engineer failing to change the sizing j

AP from the previously sized motor operator'on a computer program.

~

l l

l

- _ _.., ~

- - - - - - - ~ +

10 CFR, PART 21-([)

NOTIFICATION i..

THE DATE ON WHICH THE INFORMATION OF SUCH DEFECT OR FAILURE TO COMPLY WAS OBTAINED:

J e

21 Decembe'r 1987 IN THE CASE OF A BASIC COMPONENT WHICH CONTAINS A DEFECT OR FAILS TO COMPLY, THE NUMBER AND LOCATION OF ALL SUCH COMPONENTS IN USE AT, SUPPLIED FOR, OR BEING SUPPLIED FOR ONE OR MORE FACILITIES OR ACTIVITIES SUBJECT TO THE REGULATIONS IN THIS PART:

Supply of undersized valve operators is limited to C.E.I., Co., Perry Nuclear Generating Station.

The number and identification of these valves are: - 0jI, F/M ;No q RNU-205,-- BWIP, As sembly-No.7 ifor Perrf Unitii1Jand.'2.1

~'

81200 supplied'- -

~'

THE CORRECTIVE ACTION WHICH HAS BEEN, IS BEING, OR WILL BE TAKEN; THE NAME OF THE INDIVIDUAL OR ORGANIZATION RESPONSIBLE FOR THE ACTION: AND THE LENGTH OF TIME THAT HAS BEEN OR WILL BE TAKEN TO COMPLETE THE ACTION:

Replace the existing operatori(SMB-00-15) with an SMB-25 as'soon as 4

possible. The user is aware of a potential problem, and has been advised through a copy of this letter. Other calculations performed by the same engineer have been identified, checked and found to be in order.

scJ have determined that thi operator sizing cal'culation error is' limited ito this valve ~ assembly, atta. review'of the' motor operator ' sizing

~

~

calculations for all remaining valies supplied to:. Perry. Nuclear have.

shown to be co'rrect.

During the interim needed to acquire a new operator, the operator from the valve assembly of B/M RNU-204 Unit 2 valve in Perry warehouse can be utilized.

ANY ADVICE RELATED TO THE DEFECT OR FAILURE TO COMPLY ABOUT THE FACILITY, ACTIVITY, OR BASIC COMPONENT THAT HAS BEEN, IS BEING, OR WILL BE GIVEN TO PURCHASERS OR LICEN1EES:

Advise to other purchasers or licensees are not applicable.

J