PNO-77-086:on 770518,eight Horizontal Cracks Five to Seven Inches in Length Identified in Area Just Below CRD Nozzle on Reactor Vessel Wall.Licensee & GE Evaluating Cracks.Media Interest Not Expected & Press Release Not Planned
ML20151U630
Person / Time
Site: Peach Bottom 
Issue date: 05/19/1977
From: Constable L, Sniezek J, Thornburg H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To:
References
PNO-77-086, PNO-77-86, NUDOCS 9809110087
Download: ML20151U630 (1)


Text

VT% GW pg y gigLge

~ ^ ^ - ^ - - ^ ^ ~ ~ ^ ^ - ' ^

W

-s.a PRELIMINARY NOTIFICATION

=% v mr--

m.

y PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE--PNO-77-86 This preifminary notification constitutes EARLY notice of an event of POSSIBLE safety or public interest significance. The information presented is as initially received without verification or evaluation

_and is basically all that is known by IE staff on this date Facility: Philadelphia Electric Company (PECo)

Peach Bottom Unit No. 2 (DN 50-277)

Delta, Pennsylvania

Subject:

VESSEL WALL CRACK INDICATIONS BELOW CONTROL ROD DRIVE (CRD)

RETURN N0ZZLE Penetrant Testing of CRD return nozzle repairs extended to a small area of the vessel wall I.D.

Eight horizontal cracks five to seven inches in length were identified in an area just below the CRD nozzle on the reactor vessel wall. A t.hree inch length in the worst crack has been ground 0.050 inches into base metal beneath the 1/8 inch stainless steel clad. The indication still exists. The licensee and GE are evaluating the cracks.

t 4

Media interest is not expected. The State of Pennsylvania has been i

)

informed. A press release is not planned.

NRC, Region I, (Philadelphia) received notification of this occurrence by telephone from the Plant Superintendent at 3:11 p.m. on May 18, 1977, and is following the situation closely, l

pl;

Contact:

LConstable, IE x27451 JSniezek, IE x27451-HThornburg, IE x27265 7

1 Distribution: Transmitted H St / W 7 g'

A Chairman Rowden C. C. Kammerer, CA G. F. Murphy, JCAE O

f$i Commissioner Kennedy S. J. Chilk, SECY H. H. Whiteside, JCNR 2 Commissioner Gilinsky H. R. Myers, HCEE Transmitted: HNBBUl02 P Bldg [C N SSBldg/.'/D L. V. Gossick, ED0' E. G. Case, NRR C. V. Smith, NMSS S. H. Hanauer, EDO J. A. Harris, PA W. G. Mcdonald, MIPC Luge (MAIL)

E. Volgenau, IE R. G. Ryan, OSP T. J. McTiernan, OIA Region " E 3 2 H. K. Shapar, ELD w w

~ ' ' '

PRELIMINARY NOTIFICATION

y 9009110087 770519 PDR 18 E PNO-77-006 PDR LOO M