gc0 08%g),

UNITED STATES

+

[,

i NUCLEAR REGULATORY COMMISSION j

WASHINGTON, D, C. 20555

/

August 3, 1988 PHILADELPHIA ELECTRIC COMPANY PUBLIC SERVICE ELECTRIC AND GA5 COMPANY DELMARVA POWER AND LIGHT COMPANY ATLANTIC CITY ELECTRIC COMPANY DOCKET NO. 50-277 PEACH BOTTOM ATOMIC POWER STATION, UNIT N0. 2 nMENDMENT TO FACILITY OPERATING LICENSE Amendment No.134 License No. DPR-44 1.

The Nuclear Regulatory Consission (the Cosmission) has found that:

A.

The application for amendment by Philadelphia Ei*ctric Company, et al. (the licensee) dated October 19, 1987, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Consission's rules and regulations set forth in 10 CFR Chapter I.

B.

The facility will operate in confonnity with the application, the provisions of the Act, and the rules and regulations of the Conmission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Cosmission's regulations; D.

The issuance of this amendment will not be inimical to the cosmon defense and security or to the health or safety of the public; and E.

The issuance of this amendment'is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C(2) of Facility Operating License No. DPR-44 is hereby amended to read as follows:

8808160261 880803 PDR ADOCK 05000277 P

PNU

_. _ _ _ _ _ _ _ _ _ _ - - _ _ _ _ _ _ _. - _ - _. _, _ _ _ _ _ _ _ _ _.. _. _. _ _. _.. _ _ _... _..,... ~..

e a

, (2)

Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 134, are hereby incorporated in the license. PEC0 shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of its date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION Robert E. Martin for Walter R. Butler, Director Project Directorate I-2 Division of Reactor Projects I/II

Attachment:

Changes to the Technical Specifications Date of Issuance: August 3, 1988 l

e

tr n

)

/80

/ ['y88

}/9,/88l

/L 88

. (2)

Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 134, are hereby incorporated in the license. PECO shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of its date of issuance.

FOR THE NUCLEAR REGULATORY CO M ISSION

{$k alter R. Butler, Director Project Directorate I-2 Di'rision of Reactor Projects I/II

Attachment:

Changes to the Technical Specifications Date of Issuance:

August 3, 1988 l

s 1

I l

i

.6 J

ATTACHMENT TO LICENSE AMENDMENT NO.134' FACILITY OPERATING LICENSE NO. DPR-44 00CKET NO. 50-277 Replace the following-page.of the Appendix A Technical Soecifications with the enclosed pace. The revised areas are indicated by marginal lines.

Remove Insert 77 77 r

[

s i

'4 i

l l

l l

4 TABLE 3.2.F SURVEILLANCE INSTRUMENTATION Minimum No.

{

of Operable Type Instrument Indication

~

Ites Channels Parameter Instrument and Range Action" sa 1

2 Reactor Water Level LR-2(3)-6-%

Recorder 0 to 60 inches (1) (2) (3) g (narrow range)

LI-2("l)-6-94A,B,C Indicator 0 to 60 inches h

2 2

Reactor Water Level LR-2(3)-2-3-110A,8 Recorder -165 to +60 inches (10) (11)

(wide ran0e)

(Green Pen) k 3

2 Reactor Water Level LR-2(3)-2-3-110A,B Recorder -325 to +60 inches (10) (11) j (fuel zone)

(Red Pen) g4 2

Sear. tor Pressure PR-2(3)-6-%

Recorder 0 to 1500 psig (1) (2) (3)

PR-2(3)-2-3-404A,8 Indicator 0 to 1200 psig PI-2(3)-6-SOA,B,C E%

4 5

2 Drywell Pressure PR-4(5)805 (Pen 2) Recorder 0 to 70 psig (1) (2) (3)

Y PR-2(3)S08 (Pen 2)

E%

6 2

Drywell Pressure PR-8(9)102A,8 Recorder 0 to 225 psig (8) (9) m (wide range)

(Red Pen) i 7

2 Drywell Pressure PR-8(9)102A,8 Recorder 5 to 25 psia (8) (9)

(subataospheric (Green Pen) rany) 1 8

2 Drywell Temperature TR-4(5)805 (Pen 1) Recorder 40 to 440 degrees F (1) (2) (3)

TI-2(3)S01 Indicator 40 to 440 degrees F (1) (2) (3) (12) 9 2

Suppression Chamber TR-8(9)123A,B Recorder 30 to 230 degrees F (1) (2) (3) (6) j Water Temperature TIS-2(3)-2-71A,B Indicator 30 to 230 degrees F 10 2

Suppression Chamber LR-8(9)027 Recorder 13.7 to 15.7 feet (1) (2) (3)

Water 1.ttel (narr w LI-8(9)027 Indicator 13.7 to 15.7 feet range) o

sana efs uq'o, UNITED STATES NUCLEAR REGULATORY COMMISSION j

WASHINGTON, O. C. 20555

's, s/

f PHILADELPHIA ELECTPIC COMPANY PUBLIC SERVICE ELECTRIC AND GA5 COMPANY DELMARVA POWER AND LIGHT COMPANY ATLANTIC CITY ELECTRIC COMPANY l

DCCKET N0. 50-278 PEACH BOTTOM ATOMIC POWER STATION, UNIT NO. 3 AMENDMENT TO FACILITY OPERATING LICENSE l

Amendment No. 137 License No. OPR-56 1.

The Nuclear Regulatory Commission (the Commission) has found that:

j A.

The application for amendrent by Philadelphia Electric Company, et al. (the licensee) dated October 19, 1987, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I.

B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Coenission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health or safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendnent, and paragraph 2.C(2) of Facility Operating License No. OPR-56 is hereby amended to read as follows:

s I

I l

I

(2)

Technical Specifications The Technical Specifications contained in Appindices A and B, as revised through Amendment No.137, are hereby incorporated in the license.

PECO shall operate the facility in,accordance with the Technical Specifications.

3.

This license amendment is effective as of its date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION Robert E. Martin for Walter R. Putler, Director Project Directorate I-2 Division of Reac+or Projects I/II

Attachment:

Changes to the Technical Specifications Date of Issuance: August 3, 1988 B

i OGdkf t/D

.. klA PM rien tin:tr Atl 9

E8utler q4/ /88

{CY88

'l/p /80 7/T}/88 i

. (2)

Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.137, are hereby incorporated in the license. PECO shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of its date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION WVh $

Iter R. Tutle)r, Director Project Directorate I-2 Division of Reactor Projects I/II

Attachment:

Changes to the Technical Specifications Date of Issuance: August 3, 1988 9

t

b ATTACHMENT TO LICENSE AMENDMENT NO.13_7 FACILITY OPERATING LICENSE NO. DPR-56 DOCKET NO. 50-278 Replace the followin s page of the Appendix A Tecnnical Specifications with the enclosed page. The revised areas are indicated by marginal lines.

/

Remove Insert 77 77 g

I t,

I I

h

'h I

t I

0

[

i,

TABLE 3.2.F SURVEILLANCE INSTRUMENTAT10N Minimue No.

of Operable Type Instrument Indication Ites Channels Parameter Instrument and Range Action

  • Er I

1 2

Reactor Water Level LR-2(3)-6-%

Recorder 0 to 60 inches (1) (2) (3) g (narrow range)

LI-2(3)-6-94A,8,C Indicator 0 to 60 inches 2

2 Reactor Water Level LR-2(3)-2-3-110A,8 Recorder -165 to +60 inches (10) (11)

(wide ranes)

(Green Pen) 3 2

Reactor Water Level LR-2(3)-2-3-110A,B Recorder -325 to +60 inches (10) (11) i (fuel zone)

(Red Pen) 4 2

Reactor Pressure PR-2(3)-6-%

Recorder 0 to 1500 psig (1) (2) (3)

PR-2(3)-2-3-404A,8 Indicator 0 to 1200 psig y

PI-2(3)-6-90A,B.C g

o y5 2

Drywell Pressure PR-4(5)805 (Pen 2) Recorder 0 to 70 psig (1) (2) (3)

[

4 PR-2(3)S08 (Pen 2) 1 6

2 Drywell Pressure PR-8(9)102A,8 Recorder 0 to 225 psig (8) (9) o (wide range)

(Red Pen) 4 7

2 Drywell Pressure PR-8(9)102A,E Recorder 5 to 25 psia (8) (9)

(subatmospheric (Green Pen) range) 8 2

Drywell Temperature TR-4(S)805 (Pen 1) Recorder 40 to 440 degrees F (1) (2) (3) l TI-2(3)S01 Indicator 40 to 440 degrees F (1) (2) (3) (12) 1 9

2 Suppression Chamber TR-8(9)123A,B Recorder 30 to 230 degrees F (1) (2) (3) (6)

Water Temperature TIS-2(3)-2-71A,8 Indicator 30 to 250 degrees F 10 2

Suppression Chamber LR-8(9)027 Recorder 13.7 to 15.7 feet (1) (2) (3)

Water Level (narrow LI-8(9)027 Indicator 13.7 to 15.7 feet range) i l

l e

-