Exemption Granted Re Requirements of App J to 10CFR50, Paragraph III.A.3 to Allow Use of Mass Point Method as Requested in Submittal
ML20151S822
Person / Time
Site: Oyster Creek
Issue date: 04/18/1988
From: Varga S
Office of Nuclear Reactor Regulation
To:
GENERAL PUBLIC UTILITIES CORP.
Shared Package
ML20151S826 List:
References
NUDOCS 8804280480
Download: ML20151S822 (5)


Text

.

7590-01 UNITED ~ STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of GPU NUCLEAR CORPORATION AND Docket No. 50-219 JERSCY CENTRAL POWER AND LIGHT COMPANY (0yster Creek Nuclear Generating

)

Station)

)

EXEMPTION I.

The GPU Nuclear Corporation and Jersey Central Power & Light Company (the licensee) are the holders of Provisional Operating License No. OPR-16, which authorizes operation of the Oyster Creek Nuclear Generatiilg Station, (the facility) at steady state reactor core power levels not in excess of 1930 l

megawatts thermal. The license provide;, among other things, that Oyster Creek Nuclear Generating Station is subject to all rules, regulations, and Orders of the Commission now or hereafter in effect.

The plant is boiling water reactor (BWR) located at the licensee's site in Ocean County, New Jersey, II.

i l

The Code of Federal Regulations,10 CFR 50.54/o), specifies that primary reactor containments for water-cooled power reactors shall comply with Appendix J, "Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors." Paragraph III.A.3 of Appendix J incorporates by reference the American National Standard ANSI N45.4-1972, "Leakage Rate Testing of Coiltainment Structures for Nuclear Peactors." This standard requires that 8804280400 880418 ADOCK 050 9

gDR

. containment leakage calculations for Containment Integrated Leakage Rate Tests-(CILRTs) be performed using either the point-to-point method or total time method.

A more recent standard, ANSI /ANS 56.8-1981, "Containment System Leakage Testing Requirements," which was intended to replace ANSI N45.4-1972, specifies the use of the mass point nethod to the exclusion of the two older methods.

A proposed revision to Appendix J, which has been published for public coment (53 FP. 5985, February 29,1988) would permit the use of the mass point method provided it is used with a test duration of at least 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

Pending approval of the revision to Appendix J, licensees who wish to use the mass point technique must submit an application for partial exemption from the requirement that Appendix J test ca'culations for CILRTs will conform with ANSI N45.4-1972.

III.

By letter dated February 19, 1988, the licensee requested a partial exemption from 10 CFR Part 50, Appendix J Paragraph III.A.3, which requires that all CILRTs be perfomed in accordance with ANSI N45.4-1972, "Leakage Rate Testing of Containment Structures for Nuclear Reactors." ANSI N45.4-1972 l

requires that leakage calculations be performed using either the total tine l

method or the point-to-point method. The licensee has stated in support of the application for exemption from Appendix J that the mass point n:ethod is a more 1

accurate method of calculating containment leakage.

l

. It has been recognized by the professional connunity that the n' ass point method is superior to the two other methods, point-to-point and total tine, which are referenced in ANSI N45.4-1972 and endorsed by the present regulations.

The mass point nethod calculates the air mass at each point in tin;e, and plots it against time. A linear regression line is plotted through the mass-time points using a least square fit. The slope of this line is the leakage rate.

In addition to the niethod of calculation, consideration of the length of the test should also be included in the overall program.

In accordance with Section 7.6 of ANSI N45.4-1972, a test duration less than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> is only allowed if approved by the NRC, and the only currently approved methodology for such a test is contained in Bechtel Topical Report BN-TOP-1, Revision 1 "Testing Criteria for Integrated Leakage Rate Testing of Primary Containnent Structures for Nuclear Power Plants," dated November 1, 1972. This approach only allows use of the total tinie method. Therefore, the staff will condition the exenption to require a mininium test duration of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the mass point nethod is used.

The licensee's letter also submitted information to identify the special circunistances for granting this exemption for Oyster Creek Nuclear Generating Station pursuant to 10 CFR 50.12.

The purpose of Appendix J to 10 CFR Part 50 is to assure that containment leak-tight integrity can be verified periodically throughout the service lifetin.e so as to maintain containnient leakage rate l

within the limit specified in the plant technical specifications.

The underlying purpose of the rule specifying particular nethods for calculating leakage rates 1

t

4 is to assure that accurate and conservative methods are used to assess the results of containment leakage rate tests. As set forth above, the mass point method has been a widely used method providing accurate results and the staff has determined that this method of calculating leakage rate satisfies the purpose of the rule.

Based on the above discussion, the licensee's proposed partial exenption from paragraph III.A 3 of Appendix J, to allow use of the mass point niethod as requested in the submittal dated February 19, 1988, is acceptable with the condition of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> mininum test duration, until such provision of Appendix J is n>odified.

The exemption applies only to the method of calculating leakage rate by use of the nrass point method and not to any other aspects of the tests.

IV.

Accordingly, the Conmission has detennined that, pursuant to 10 CFR Part 50.12, this exemption is authorized by law, will not present an undue risk i

to the public health and safety, and is consistent with the conson defense and I

security. The Comission has further detennined that special circumstances, as set forth in 10 CFR 50.12(a)(2)(ii), are present justifying the exemption, nan.ely that the application of the regulation in the particular circumstances is not necessary to achieve the underlying purpose of the rule. Accordingly, the Conmission hereby grants an exemption as described in Section III above from Paragraph III.A.3 of Appendix J to the extent that the mass point method l

l 1

. may be used for containment leakage rate calculations, provided it is used with a minimum test duration of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. The exemption is granted until such provision of Appendix J is modified. The exemption applies only to the method of calculating leakage rate by use of the a: ass point n;ethod and not any other aspects of the tests.

Pursuant to 10 CFR 51.32, the Commission has determined that the granting of this exemption will have no significant inipact on the environment (53 FR.12617 April 15, 1988).

l This exemption is effective upon issuance, l

F0 THE NUCL GULATORY COMMISSION A idh ven rga, Dire r

Division of Reactor P oj cts-I/II Office of Nuclear Reac r Regulation l

l Dated at Rockville, Maryland this April 18,1988 l