Forwards Rev 4 to Pvngs,Unit 1 Colr,Rev 1 to Unit 2 COLR & Rev 6 to Unit 3 Colr,Per Plant TS Amend 117,section 5.6.5.d. Revs Include Changes That Were Required to Implement Amend 117 That Reduce 100% Power Negative Mtc Limit
ML20151S079
Person / Time
Site: Palo Verde  Arizona Public Service icon.png
Issue date: 08/21/1998
From: Krainik A
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20151S083 List:
References
102-04170-AKK-S, 102-4170-AKK-S, NUDOCS 9809020024
Download: ML20151S079 (2)


Text

--

Angela K. Krainik Departrnent Leader Regulatory Affairs Mao Station 7636 Palo Verde Nuclear Tet 602/393-542'.

o O Bor52034 Generating Station Fax 602/393 5442 Dnoenix AZ 85072-2034 102-04170-AKK/SAB/RMW August 21,1998 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Station P1-37 Washington, DC 20555-0001

Dear Sirs:

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Units 1,2 and 3, Docket Nos. STN 50-528,-529,-530 Core Operating Limits Reports (COLRs), Uniti,2 and 3, Revisions 4,1 and 6, Respectively.

Pursuant to PVNGS Technical Specifications, Amendment 117, Section 5.6.5.d, enclosed are the COLRs for Units 1, 2 and 3, Revisions 4,1 and 6, respectively.

These revisions were made effective on August 13, 1998, coincident with the implementation of Amendment 117 of the PVNGS Technical Specifications.

The changes implemented by these revisions include changes that were required to implement Amendment 117 and that reduce the 100% power negative MTC limit. In addition, Revision 6 to the Unit 3 COLR decreases the Axial Shape Index (ASI) allowable limits of operation at reactor power levels greater than or equal to 50% with the Core Operating Limit Supervisory System (COLSS) operable and increases the Linear Heat Rate Limit to 13.1 kW/ft. These revisions replace the previous COLR for each respective unit in their entirety.

By copy of this letter and the enclosure, these COLR revisions are being provided to the NRC Region IV Administrator and the PVNGS Senior Resident inspector.

This letter does not make any commitments to the NRC. Please contact Scott A. Bauer at (602) 393-5978 if you have any questions or require additional information.

9809020024 980821 DR ADOCK 0500o528 Lj p

PDR

.iJ AKK/SAB/RMW/rth s.*

Enclosure cc:

E. W. Merschoff M. B. Fields J. M. Moorman

t 4

d.

i j

i Enclosure i

j Core Operating Limits Reports PVNGS Units 1,2 and 3 Revisions 4,1 and 6, Respectively f

4 i

l

-..