ML20151Q789

From kanterella
Jump to navigation Jump to search
Forwards STP.1154, Remote Shutdown Panel Test, Casualty Procedure OP-C.13A, Remote Shutdown, Comparison of Subj Procedures & Evaluation of Appropriateness of Casualty Procedure OP-C.13A Steps to Secure Reactor Coolant Pumps
ML20151Q789
Person / Time
Site: Rancho Seco
Issue date: 04/15/1988
From: Andognini G
SACRAMENTO MUNICIPAL UTILITY DISTRICT
To: Miraglia F
Office of Nuclear Reactor Regulation
Shared Package
ML20151Q793 List:
References
GCA-88-248, NUDOCS 8804270136
Download: ML20151Q789 (1)


Text

Esuun SACRAMENTO MUNICIPAL UTILITY DISTRICT C P. O. Box 15830, Sacramento CA 95832-1830,(916) 452 3211 AN ELECTRIC SYSTEM SERVING THE HEART OF CALIFORNIA APR 15 sss GCA 88-248 U. S. Nuclear Regulatory Commission Attn: Frank J. Miraglia, Jr.

Associate Director for Projects 11555 Rockville Pike Rockville, MD 20852 l

Docket No. 50-312 Rancho Seco Nuclear Generating Station License No. DPR-54 REMOTE SHUTDOWN TESTING l

References:

(i) Andognini to Miraglia (GCA 88-029), January 25, 1988.

(ii) Andognini to Miraglia (GCA 88-061), February 8,1988.

(iii) Andognini to Miraglia (GCA 88-097), February 22, 1988

Dear Mr. Miraglia:

As previously committed, this letter forwards information concerning the remote shutdown test. provides STP.1154, "Remote Shutdown Panel Test." This procedure is consistent with the test descriptions provided in the referenced correspondence. provides a comparison of Casualty Procedure OP-C.13A, "Remote Shutdown" (provided in Attachment 3), and STP.ll54.

1 provides an evaluation of the appropriateness of Casualty Procedure OP-C.13A steps which secure the reactor coolant pumps.

This evaluation concludes that OP-C.13A, as presently written, provides appropriate assurance that safety barriers are maintained.

j Please contact me if you have any questions. Members of your staff with i

questions requiring additional information or clarification may contact l

Mr. David S. Compton at (209) 333-2935, extension 4915.

Sincerely, ho$

k2 i

'G. Carl Andognini j h(o l

Chief Executive Officer, Nuclear g

I cc:

G. Kalman, NRC, Rockville A. D'Angelo. NRC, Rancho Seco l

J. B. Martin, NRC, Walnut Creek l

RANCHO SECO NUCLEAR GENERATING STATION O 1444o Ten Cities Road, Herald, CA 95638-9799.(209) 333-2935