ML20151Q000

From kanterella
Jump to navigation Jump to search
Amend 1 to License SNM-1892 for Manhattan College,Amending License in Entirety
ML20151Q000
Person / Time
Site: 07002951
(SNM-1892-A-01, SNM-1892-A-1)
Issue date: 09/18/1987
From: Johansen J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20151Q003 List:
References
NUDOCS 8804260300
Download: ML20151Q000 (3)


Text

_ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _

--=---m----


E==_-----

.w------m==-3 p! NRC Fom 374 (fS. NUCLEAR REGULATORY COMMISSION

[h PAGE

\\

l

/ \\

}

3 PAGES pso

't

(

MATERIALS LICENSE Amendment No. 01 Pursuant to the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93-438), and Title 10, i; Code of Federal Regulations, Chapter I. Parts 30,31,32,33,34,35,40 and 70, and in reliance on statements and representations j heretofore made by the licensee, a license is hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct, j source, and special nuclear material designated below; to use such material for the purpose (s) and at the place (s) designated below;to li deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the appheable Part(s). This ji license sha'l be deemed to contain the con iitions specified in Section 183 of the Atomic Energy Act of 1954, as amended, an 1 is l subject to all applicable rules. regulations and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any e l___

(y;g

. ! conditions specified below.

j ueensee l

In accordance with application dated i

l l

3 Lic'y 22, 1987, Ma "S*"""* "

SNM-1892 is amended in lh Manhattan College its entirety to read as follows

r1 2.

hanhattan College Parkway

~ ~

~ -~ ~

~ ~ ~ ~ ~

g)$

Riverdale, New York 10471

4. Expiration date September 30,1992 l
5. Docket m Reference No.

070-02951 l 6. Ilyproduct, source, and/or

7. Chemical and/or physical
8. Maximum amount that licensee p

l!

special nudear material form may possess at any one time h

under this license j

j h;;;

h A. Plutonium 239 A. Mound Laboratories or A. 80 grams contained in l

Nuclear Materiels and five 16 gram sources l

Equipment Corporation j;l I

sealed Pu-Be neutron

p$

l sources tl B. Plutenium 239 B. Mound Laboratories cr B.160 grarns contained in

ba Nuclear Materials and two 80 gram sources y'

h*:

Equipttent Corporation j

fq-sealed Pu-Be neutron

-p l4 d!

sources 4

[-

'i.l f

h h

9.

Authorized use P;

6 bl

, tn A.

For use in a graphite mcdcrated subcritical assembly for it,boratory experiments j;

and student instruction.

41 l

B.

For use in a water subcritical assembly and c water moderated neutron howitzer for y,

b laboratory experiments and student instruction.

M; CONDITIONS p,

j ri; Eql 10 Licensed tr.aterial shall be used only at The Manhatton College Nuclear Reactor 31 2

Laboratory, Engineering building, Corlear Avenue, Bronx, New York.

d j

l74 l

ib4 l

l 11.

Licensed material shall be used by, or under the supervision of, Stanley Malsxy, f

Ph.D., Robert Berlin, Ph.D. (RS0) or Jih-Perng Hu, Ph.D.

N 1

,b)

s

+5 1

P i

'\\

l l

"OR A RECORD COPY" b

0804260300 B70918 h'-

M REG 1 L7C70

[g$

j 4

sNM-lava pon

!A ikemanuxxaname-awaamx.mxaaxxunan,xaax,u.,,.4

.......x....

U.S. NUC REGULATORY COMMISSION 2

3 h

y PAGES Fprm 374A PAGE

(

License number f

SNM-1892 MATERIALS LICENSE i

(

SUPPLEMENTARY SHEET gg 4

Amendment No. 01 p$

d N

(Continued)

CONDITIONS I

4 q

12. A(1) Each sealed source or detector cell acquireo f rom another person ano i

containing licensed material, other than hydrogen 3, with a half-life d

greater the-30 days ano in any form other than gas sha11 be tested for W,91 4

contaminattor, and/or leakage before use.

In the absence of a certificate l

from a transferor indicating that a test has be.in made within 6 months M

before the transfer, a sealed source or detector cell received from g

q another person shall not be put into use until tested.

p3 q

M]

4 4

(2) Notwithstanding the periodic leak test required by this condition, any licensed sealed source or detector cell is exempt from such leak tests PJ j

when the source or detector cell contains 100 microcuries or less of beta g

q and/or gamma emitting materials or 10 microcuries or less of alpha p

4 p'

W emitting material, h!

i 4

f@

4 (3) Except for alpha sources, the periodic leak test required by this condi-i tion does not apply to sealed sources that are stored and not being used.

l The sources excepted from this test shall be tested for leakage before any use or transfer to another persen unless they have been leak tested g

4 within 6 months berore the date of use or transfer, pj q

p B.

Each sealed source or detector cell fabricated by the licensee shall be f,

inspected and tested for construction defects, leakage, and contamination W

prior to use or transfer as a sealed source or detectcr cell.

If the ld inspection or test reveals any ccnstruction defects or 0.005 microcurie l

fl or greater of contamination, the scurce shall not be used or transferred ip jf as a sealed source or detector cell until it has been repaired, decontami-9

.bj I4 nated and retested.

N l

C.

Each sealed source containing licenseo material, other than hydrogen 3, y

I with a half-life greater than 30 days and in any form other than gas p

a shall be tested for leakage and/or contanination at intervals not to p'

W exceed 6 months except that each source designed for the purpose of emitting alpha particles shall be tested at intervals not to exceed 3 l1

I l months.

D.

The test shall be capable of detecting the presence of 0.005 microcurie of radioactive material on the test sample.

The test sample shall be I

%g taken from the sealed source or detector cell or from the surfaces of the 4

device in which the sealed source or detector cell is permanently or

%M

,4l semipermanently mounted or stored on which one might expect contamination iM to accumulate. Records of leak test results shall be kept in units of ig j J{4 microcuries and maintained for inspection by'the Commission.

Records may Ig be disposed of following Cocinission inspection.

ri l

i i

f a

I'l n

a f*l 1

h P

!4 4

AMXThJdr 67sWEfEd.MtJfr7dir iT2CrF2CifiM2DCrZfuridEEdr2rhJrjrh.nfJrs2sDrJr

^

p ucense number g

-1892 MATERIALS LICENSE h

SUPPLEMENTARY SHEET O-02951 h

Amendment No. 01 h) hj 4

(12. Continued)

CONDITIONS h

IN 4

If the rest requireo by Subsection A. or C. of this condition reveals the lp

!q E.

4 presence of 0.005 nicrccurie or more of ren,ovable contamination, the pl

'4 1icensee shall ineeciately withdraw the scaled duurce or detector cell

'i from use and shall cause it to be decontaminated and repaired or to be ElM N

disposec of in accordance with Corrmission regulations. A report shall be Q

filed within 5 days of the date the leak test result is known with the I

Q U. S. Nuclear Regulatory Cannission, Region 1, ATIN:

Chief, Nuclear Q

k Materials Safety and Safeguards Branch, 631 Park Avenue, King of Prussia,

4 Pennsylvania 19406, describing the equipment involved, the test results,

,J i

and the corrective action taken.

I' lj (13.

Sealed sources containing licensed material shall not be opened.

M 4

4

14. The licensee may transport licensed material in accordance with the provisions M

of 10 CFR Part 71, "Pc kaging and Transportation of Radioactive Material".

ib)

N FI This license does not authorize the insertion of materials into any nuclear hl f;15.

reactor, hotwithstanding Condition 12. A.(1), sources inserted into a reactor under h

(4 other license authocity shall be tested for leakage when removed from the reactor j,1 k

in tccordanc: with the requirements of Condition 12. A.(1) before returning to use M

or storage uncer this licenie.

bj Il (q16. Except as specifically provided otherwise in this license, the licensee shall g

J conduct its program in accordance with the statements, representations, and l4, procedures contained in the documents including any enclosures, listed below,

hj
l The Nuclear Fegulatory Connission's regulations shall govern unless the jp) statements, representations and procedures in the licensee's application b

$q and correspondence cre more restrictive thin the regulations.

N 8

h A.

Application dated January 27, 1982 I[]

{W B.

Letter detec June 2,1982 1

Applica tion deteo Fa,v 22, 1987 y

I i'.

nI s

W s

W 4

4 tW li;

!N l

l$

f i1 4

'4 li 4

3 N

91

>j>

lj for the U.S. Nuclear Re9ulatory Conmi,ssion h

3

" 8 ' ""' S ' *" * * ""

jl4 18 SEP 1987

  1. '""Y**#*h""8'"

Date _

By l

huclear Materials Safety and g

q 4

Safeguards Branch, Region I N

A King of Prussia, Pennsylvania 19406 9

t.lT&THJCKf20MfT2CCETITY5KTx=LTararaTmTJearaTa'sur.TsTJerem T;r2raras.Tzsrar.T

--- -