Safety Evaluation Supporting Amends 50 & 43 to Licenses NPF-35 & NPF-52,respectively
ML20151M641
Person / Time
Site: Catawba  
Issue date: 07/28/1988
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20151M637 List:
References
NUDOCS 8808050262
Download: ML20151M641 (3)


Text

.

r uog*o UNITED STATES g

g NUCLEAR REGULATORY COMMISSION o

5 l

WASHINGTON, D. C. 20555

\\,

/

SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATED TO AMENDMENT N0. 50 TO FACILITY OPERATING LICENSE NPF-35 AND AMENDMENT NO. 43 TO FACILITY OPERATING LICENSE NPF-52 DUKE POWER COMPANY, ET AL.

DOCKET NOS. 50-413 AND 50-414 CATAWBA NUCLEAR STATION, UNITS 1 AND 2 INTRODUCTION (the licensee)

By letter dated April 1,1988, Duke Power Company, et al.} 5.3.1 "Fuel propused amendinents to change Technical Specification (TS Assemblies" to provide increased flexibility (in the substitution of solidi.e., vacancies) fo stainless steel rods and open water channels in reconstitutible fuel asserblies to be reinserted in the reactor core during a refueling outage.

Presently, TS 5.3.1 requires that each fuel assedly contain 264 fuel rods clad with Zircaloy-4, except that limited substitutions of fuel rods with filler rods consisting of Zircaloy-4 or stainless steel, or by vacancies, may be made in peripheral fuel assemblies if justified by cycle-specific reload analyses.

The revised TS 5.3.1 would require that each fuel asserrbly nominally contain 264 fuel rods clad with Zircaloy-4, except that substitutions of fuel rods by filler rods consisting of Zircaloy-4 or stainless steel, or by vacancies, may be made in fuel assemblies if justified by cycle-specific reload analyses using NRC-approved methodology. The proposed revision would also state that should more than 30 rods in the core, or 10 rods in any assed ly, be replaced per refueling, a special report describing the number of ruds replaced would be submitted to the Commission pursuant to Specification 6.9.2 within 30 days after cycle startup.

The licensee's letter of April 1, 1988 superseded portions of a previous request dated February 5, 1988, which was not accepted by the NRC because it did not clearly specify requirements for analyses by the licensee to be performed for each reload using NRC-approved methodology.

l EVALUATION l

l The proposed change provides increased flexibility by the removal of "limited substitutions" and "peripheral fuel assemblies." Under the proposed change, limitations on fuel rod substitution or omissions and limitations regarding core locations are those implicit in the justifying analyses required to be performed by the licensee for each fuel cycle using NRC-approved methodology I

to demonstrate that existing design limits and safety analyses continue to be met.

The term "NRC-approved methodology" includes those methodologies acknowledged in the FSAR and applied in support of issuance of the original operating licenses for Catawba Nuclear Station, Units 1 and 2.

Additionally, it includes those subsequent methodologies which have been submitted to and accepted by the staff after the issuance of the Catawba operating licenses.

8800050262 8e0728 l

DR ADOCK 0500 3

\\

For example, by letter dated liarch 13, 1985, the NRC staff approved Duke Power Company's topicai report DPC-NF-2010 titled "McGuire Nuclear Station 1/ Catawba Nuclear Station Ph sics Methodology for Reload Design," dated April 1984.

/

As noted in NRC Gen 0ric Letter 83-11, "Licensee Qualifications for Performing Safety Analyses in Support of Licensing Actions," each licensee or vendor who intends to use a safety analysis methodology to support licensing actions must demonstrate their proficiency in using the methodology by submitting verifi-cation performed by them, not others. Thus, methodologies approved by the NRC for a specific vendor may be used by that vendor in support of Catawba reload design and anlysis; use of that methodology by other than that vendor does not constitute "NRC-approved methodology" unless specifically authorized by the NRC.

The proposed flexibility is intended to provide for improved fuel performance by permitting timely removal of individual fuel rods which are found during a refueling outage to be leaking or are deemed to be candidates for future leakage. These improvements in the licensee's fuel performance program will provide for reductions in future occupational radiation exposure and plant radiological releases.

The licensee's present goal for fuel reliability improvement (Reference a) is that the cycle average steady-state lodine-151 activity, corrected for tramp contribution and normalized to a common purification rate, remain below 0.02 microcuries per gram. This corresponds to about 12 leaking fuel rods.

The licensee's goal is to achieve one-half the present goal, or 0.01 microcuries per gram, by 1990 and beyond.

This will be achieved, in part, by an action plan of outage inspections and reconsti-tution; if the 1-131 activity exceeds 0.05 microcuries per grain any time during the cycle, ther all of the reconstitutible assemblies to be reinserted will be examined by special ultrasonic testing (UT) equipment for defects in individual failed rods and results used for reconstitution decisions.

Fuel handling, UT, and reconstitution of failed assemblies of a reconstitutible top-nozzle design would be conducted in parallel during refueling outages.

The licensee estimates the fuel improvement program will reduce the total station occupational dose by at least 5 to 10 percent.

Radiological releases from the station during normal operation would also be significantly reduced because of improved fuel performance.

The requirement for special reporting is consistent with existing TS 6.9.2 and is proposed in response to the NRC's request to be informed in the event a significant deviation from past fuel performances should be observed during l

a refueling outage.

1 i

Accordingly, we find that the proposed revision of TS 5.3.1 does not result in any significant adverse change in the process for determining the adequacy of reload designs and associated safety analyses. The licensee will continue to justify each cycle-specific reload by analyses using NRC-approved methodology in order to demonstrate that existing design limits ano safety analyses criteria are met in advance of cycle operation.

The proposed change does not l

increase the probability or consequences of accidents.

As discussed above, no j

adverse changes are being made in the types or amounts of effluents that may be released offsite, and there is no significant increase in the allowable individual or cumulative occupational radiation exposure. The licensee will continue to keep the NRC informed in a timely manner regarding any significant adverse change in its fuel performance program.

Therefore, we find the i

proposed change acceptable.

l l

l

4 l

. ENVIRONMENTAL CONSIDERATION Pursuant to 10 CFR 51.32 the Commission has determined that issuing these amendments will have no significant impact on the environment (53 FR 25396 ).

CONCLUSION The Comission issued a Notice of Consideration of Issuance of Amendments to Facility Operating Licenses and Opportunity for Hearing which was published in the Federal Register (53 FR 18181) on May 20, 1988. The Commission consulted with the state of South Carolina. No public coments were received, and the state of South Carolina did not have any coments.

We have concluded, based on the considerations discussed above, that:

(1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, and (2) such activities will be conducted in compliance with the Comission's regulations, and the issuance of these amendments will not be inir.ncal to the common defense and security or to the health and safety of the public.

REFERENCES:

(a) Memorandum by Darl Hood, "Sumary of March 28, 1988 Meeting on TS Changes Regarding Use of Steel Rods and Open Water Channels in Reconstitutible Fuel Assemblies," dated April 1, 1988, Docket Hos.

50-413/414 and 50-369/370.

Principal Contributor:

K. Jabbour, PD#II-3/DRP-I/II L. Lois, SRBX, DEST Dated:

July 28, 1988 l