Public Service Electric and Gas Company Stiven E. Miltenberger Public Service Electric and Gas Company P.O. Box 236, Mancocks Bridge, NJ 08038 609-339-4199 vice Pres 4ent ano ct.et Nuciear oecer July 27, 1988 NLR - N88110 4
U.S.
Nuclear Regulatory Commission Document Control Desk Washington, D.C.
20555 Gentlemen:
IE BULLETIN 85-03, SUPPLEMENT 1 MOTOR OPERATED VALVE SWITCH SETTINGS HOPE CREEK GENERATING STATION DOCKET NO. 50-354 Public Service Electric and Gas Company has reviewed the subject document for applicability to the Hope Creek Generating Station.
The Supplement requests that valve switch setting data (similar to that previously provided under Bulletin 85-03) be provided for all safety-related High Pressure Coolant Injection / Core Spray, and Reactor Core Isolation Cooling system valves.
PSE&G has determined that the information provided in its submittals dated May 27, 1986 and May 23, 1988 satisfies action items (a) through (f) of the Supplement for all but 1 safety-related valve.
Item 1 of Attachment 1 to this letter provides the required information on the remaining valve.
Item 2 of Attachment 1 corrects a typographical error and provides updated data for 1 valve identified in our original submittal.
If there are any questions relative to this matter, please feel free to contact us.
Sincerely, Attachment btLv t-
/
8808050001 880727 i
{DR ADOCM 05000354 I
t.
Document Control Desk 2
07-27-88 C
Mr. G. W. Rivenbark USNRC Licensing Project Manager Mr. R.
J. Kiessel U.S. Nuclear Regulatory Commission Generic Communication Branch Washington, DC 20555 Mr.
G.
W. Meyer USNRC Senior Resident Inspector Mr. W.
T. Russell, Administrator USNRC Region I Mr. D. M. Scott, Chief Bureau of Nuclear Engineering Department of Environmental Protection 380 Scotch Road Trenton, NJ 08628
--e
~,
c, 3-
---. -. - -,,r_
r.,
O ATTACHMENT 1 ITEM 1 - RCIC ISOLATION VALVE BYPASS:
VALVE VALVE OPERATOR DIFFERENTIAL PRESSURE DATA ID# FC-V048 ID# FC-HV-F076 NORMAL OPEN
- 1120 PSI MANUFACTURER - ROCKWELL MANUFACTURER - LIMITORQUE NORMAL CLOSE
-O PSI TYPE
- GLOBE MODEL
- SMB-000 ABNORMAL OPEN
- 1250 PSI SIZE
- 2" MOTOR RPM
- 1700 ABNORMAL CLOSE
- 1250 PSI RATING
- 1500 LB.
OUTPUT SPEED - 29 SECONDS TORQUE SET /OPEN
- 2.5 TORQUE SET /CLOSE - 2.5 ITEM 2 - TURBINE INLET ISOLATION:
VALVE VALVE OPERATOR DIFFERENTIAL PRESSURE DATA ID# FD-V003 ID# FD-HV-F001 NORMAL OPEN
- 1135 PSI MANUFACTURER - ANCHOR / DARLING MANUFACTURER - LIMITORQUE NORMAL CLOSE
- 1135 PSI TYPE
- GATE MODEL
- SMB-1 ABNORMAL OPEN
- 1210 PSI SIZE
- 10" MOTOR RPM
- 1900 ABNORMAL CLOSE
- 1210 PSI RATING
- 900 LB.
OUTPUT SPEED - 15 SECONDS TORQUE SET /OPEN
- 2.875 TORQUE SET /CLOSE - 3.25