ML20151L686

From kanterella
Jump to navigation Jump to search
Corrected Amend 4 to License SNM-1712 for Washington Gas Light Co,Matl Testing Lab,Amending License in Entirety
ML20151L686
Person / Time
Site: 07002475
(SNM-1712-A-04, SNM-1712-A-4)
Issue date: 09/17/1987
From: Guinn P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
NUDOCS 8804220109
Download: ML20151L686 (3)


Text

[mfMGXMMMMAMMM52TerK'KTEuri~innermwMMkurwr E Maf5f1MMw;g"mm2=x l

NIC Form 374 1

4 h

t3 sa) l U.S. NUCLEAR REGULATORY COMMISSION PAGE OF PAGES l

CORR N M MATERIALS LICENSE l

Pursuant to the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93-438), and Title 10, y

Code of Federal Regulations, Chapter I, Parts 30,31,32,33,34,35,40 and 70, and in reliance on statements and representations y

g herstofore made by the licensee, a license is hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct, p

4 source, and special nuclear material designated below; to use such material for the purpose (o and at the place (s) designated below;to y

i deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). This i

U license shall be deemej to contain the conditions specified in Sec. ion 183 of the Atomic Energy Act of 1954, as amended, and is

'N subject to all applicable rules, regulations and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any E

g conditions specified below.

l

[

ucensee

{j i

In accordance with application dated g

I 3.fghgagymb 1987 1.

l if I

Washington Gas Light Company SNM-1712 is amended in I

1 Material Testing Laboratory its entirety to read as follows:

mrm

/

6801 Industrial Road 4! hpNtik0 ate Springfield, Virginia 22151

\\-

V m h 31. 1992

-y M

J

5. Docket or Yy lp g

Reference No.

n70 02475 g

6. Byproduct, source, and/or N
7. Chemical and/or physical L8 Maximum amount that licensee 5

hay possess at any one time special nuclear material form CQ

[r, fri er thislicense N

d

/d/b

.b. NN n'

A. E' Sealed sources fy Nhtoexceed N

A.

Plutonium 238 M

}-

E(TdxnrNucleaF;0'g.g?

A.

30imi11icuries j

wQ,@f,

tf 75J 42Bflr

~q q,0; Q

PeCsource p

(f)

W b

M e

W ll, l h

(8 h deale B.

Cadmium 109 curces t, AB Not to exceed l

P/~696;69678j) ND$g.g.gdrsource.es M (Te 6s Udle'a millicuri

>1

\\k

%p p

N C.

Americium 241 C.

Fo 1 Not to exceed N/

h O.5 microcurie l

h<a per source g

}'

f>

9.

Authori ed use 6 Kh I

l{

A., B. and C.

For use in Texas Nuclear Model 9256 source holders in Texas Nuclear 9200 Series X-ray analyzers for sample analysis.

l l

t

)

l CONDITIONS j

i 10.

Licensed material shall be used only at the Washington Gas Light Company, l.

4 Materials Testing Laboratory, 6801 Industrial Road, Springfield, Virginia, and i

g at temporary job sites of the licensee anywhere in Washington, D.C. and the i

state of Virginia.

I 3

11.

Licensed material shall be used by, or under the supervision of, j

l Karl M. Gunthe., Ulysses Reed, Frank C. Parker or Charles Wientjes.

l 12.

Sealed sources containing licensed material shall not be opened or removed 4

from their respective source holders by the licensee.

6 8

8804220109 070917 lb REG 2 LIC70 SNM-171g PDR b

u g

gg gggg

mme==---~---------------- -smsmarstwanmcu NRC Form 374A U.S. NUCLEAR REGULATORY COMMISSION PAGE OF PAGEs

'"*8 uana numb" SNM-1712 MATERIALS LICENSE

"' '"""" 'M& 024 75 y

SUPPLEMENTARY SHEET CORRECTED COPY Amendment No. 04 P

f>

(cont'd)

CONDITIONS 1

13.

A.

(1) The source (s) specified in Item (s) 7. A and 7.8 shall be tested for f

leakage and/or contamination at intervals not to exceed 6 months.

1 Any source received from another person which is not accompanied by a l

certificate indicating that a test was performed within 6 months i

before the transfer shall not be put into use until tested.

p 6

(2) Notwithstanding the periodic leak test required by this condition, h

i any licensed sealed source-is exempt from such leak tests when the source contains.100 microcuries or less of beta and/or gamma emitting material or 10 microcuries or less of alpha emitting material.

i p

B.

Any source in storage and not being used need not be tested.

When the i

source is removed from storage for use or transfer to another person, it shall be tested before use or transfer.

l C.

The test shall' be capable of detecting the presence of 0.005 microcurie f

of radioactive material on the test sample.

If the test reveals the presence of 0.005 microcurie or more of, removable contamination, the p(

source shall be removed from service and decontaminated, repaired, or disposed of in accordance with Commission regulations.

A report shall M

be filed within 5 days of the date the leak test result is known with l

the U. S. Nuclear Regulatory Commission Region II, Division of Radiation p

Safety and Safeguards, Nuclear Material Safety Section,101 Marietta y

Street, Suite.2900, Atlanta, Georgia 30323.

The report shall specify the p

source involved, the test results, and corrective action taken.

Records of leak test results shall be kept in units of microcuries and shall be maintained for inspection by the Commission.

Records may be disposed of l

following Commission inspection, p

D.

The licensee is authorized to collect leak test samples for analysis t

by Texas Nuclear or tests for leakage and/or contamination shall be k

l>

performed by persons specifically licensed by the Commission or an Agreement State to perform such services.

W 14.

The licensee may transport licensed material in accordance with the provisions y

of 10 CFR Part 71, "Packaging and Transportation of Radioactive Material."

p p

15.

The licensee shall conduct a physical inventory every 6 months to account k

for all sources and/or devices received and possessed under the license.

(

Records of inventories shall be maintained for 2 years from the date of each p

inventory, p

p F

h h

E l'

max,,.x, wmyy rmm2,msr#,.cdj

7---------.

_-fac ssnewssmmnmennemesesTsmA-mmansnewsnsummenswm RC Form 374A U.S. NUCLEAR REGULATORY COMMISSION PAGE OF PAGES ueenu nwnbe' SNM-1712 y

MATERIALS LICENSE g

SUPPLEMENTARY SHEET

  • ' """** T7&l02475 CORRECTED COPY Amendment No. 04 (cont'd)

CONDITIONS 16.

Except as specifically provided otherwise in this license, the licensee shall conduct its program in accordance with the statements, representations, and l

procedures contained in the documents including any enclosures, listed below.

g The Nuclear Regulatory Commission's regulations shall govern unless the h

statements, representations and procedures in the licensee's application and correspondence are more restrictive than the regulations.

l j

Application dated February 10, 1987 l

]

i 1

1 N

1 1

1 1,

l 6

]

J P

1 b

]

1 E

I L

j L

J 1

]

I 1

1 b

i

]

i 1

E j

b

]

1

]

1 1

j 1

b; 1

b l

FOR THE U.S. NUCLEAR REGULATORY COMMISSION l

.AAAUL R. GUINN F

SEP 171987

[g j/4 mph Date gy 1

Region II, Nuclear Materials p

l Safety Section

}

101 Marietta Street, Suite 2900

>l J

Atlanta, GA 30323 1

1 I

L. - - - - - - -- - ---- - -,, = = = = = - #re _ mum.uurm:2r2r.:r r2sgg.iictEtimmerE*hT2rh>

_ _