July 26, 1988 Cockdt No. 50-213 DISTRIBUTION

  • Docket file J AWano Mr. Edward J. Mroczka

'hRC'& l'ocal PORs OGC ~

Senior Vice President SVarga Edordan Connecticut Yankee Atomic Power Conpany BBoger SGrui.6s Post Office Box 270 SNorris ACRS(10)

Hartford, Connecticut 06141-0270 Gray File Cear Mr. Mroczka:

SUBJECT:

SAFETY EVALUATION FOR NORTHEAST UTILITIES TOPICAL REPORT 140-1 "h0 SCOT:lERMALHYDRAULICMODELQUALIFICATION, VOLUME 1(RETRANf" (TAC #61048)HADDAMNECKPLANT By letter dated August 1, 1984 Connecticut Yankee Atomic Pcher Company (CYAPCO) submitted Topical Report 140-1, "NUSCO Thental Hydraulic Model (ualification, Volume 1 (RETRAN)" for staff review and approval.

CYAPC0's objective was to dencnitrate, per Generic letter 83-11, that Northeast Utilities Service Company (NUSCO), on behalf-of CYAPC0, has the technical conpetence to perfonn transient system analysis with the RETRAN computer code for the Haddam Neck Plant.

The staff has ccnpleted its review and has concluded that NUSCO has demonstrated its knowledge and technical competence for the use of the RETRAN computer code and rodels for the Haddan. Neck Plant. While the staff approves the use of the RETRAN code by NUSCO for support of future licensing submittals, any use of this code in future licensing submittals will require CYAPC0 to justify, on a transient by transient basis, the ncdalization, phenon,enological model selection, control systens modeling and licensing conservatisn;s.

This is necessary because the analysis in NUSCO 140-1 was a best-estimate analysis, used to que.lify the nodels in the code and to denonstrate NUSCO's knowledge of the code and therefore lacks the licensing conservatisms necessary for perfors.ance of transient analysis in support of liter. sing actions. The staff notes that UUCSO 151, "Haddam Neck Plant /Non-LOCA Transient Analysis" with supplements, which reanalyzes the non-LOCA design basis accidents for Haddam Neck using RETRAN, reets our prescribed guidance for your use of RETRAN and should te used as an exaq:le for future submittals.

A copy of our related Safety Evaluation is enclosed.

This conpletes all staff review of this topical.

Sincerely, original signed by Alan B. Wang, Project Fanager Project Directorate I-4 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation

Enclosure:

As stated cc w/ enclosure:

See next page

.lg LA:PDI-4 PM:PD D: Slit SKd4h AWang JSto% '

07/)f/88 07/9/88 07/pj/88 8808030327 880726 PDR ADOCK 05000213 P

PNU

.)

Mr. ' Edward J. Nroczka Connecticut Yankee Atomic Power Company Haddam Neck Plant cc:

Gerald Garfield, Esquire R. M. Kacich, Manager Day, Berry and Howard Generation Facilities Licensing Counselors at Law Northeast Utilities Service Company City Place Post Office Box 270 Hartford, Connecticut 06103-3499 Hartford, Connecticut 06141-0270 W. D. Romberg, Vice President D. O. Nordquist Nuclear Operations Manager of Quality Assurance Northeast Utilities Service Company Northeast Nuclear Energy Company Post Office Box 270 Post Office Box 270 Hartford, Connecticut 06141-0270 Hartford, Connecticut 06141-0270 Kevin McCarthy, Director Regional Administrator Radiation Control Unit Region I Department of Environmental Protection U. S. Nuclear Regulatory Comission State Office Building 475 Allendale Road Hartford, Connecticut 06106 King of Prussia, Pennsylvania 19406 Bradford S. Chase, Under Secretary Board of Selectmen Energy Division Town Hall Office of Policy and Management Haddam, Connecticut 06103 80 Washington Street Hartford, Connecticut 06106 J. T. Shedlosky, Resident Inspector Haddam Neck Plant D. B. Hiller, Station Superintendent c/o U. S. Nuclear Regulatory Comission Haddam Neck Plant Post Office Box 116 Connecticut Yankee Atomic Power Company East Hadda,n Post Office RFD 1, Post Office Box 127E East Haddam, Connecticut 06423 East Hampton, Connecticut 06424 G. H. Bouchard, Unit Superintendent Haddam Neck Plant RFD #1 Post Office Box 127E East Hampton, Connecticut 06424

- _ _ _