b JUN 2 01984

Docket No. 50-278 DISTRIBUTION Gncket _E.tls 3 EJordan NRC PDR JNGrace L PDR WJones Mr. Edward G. Bauer, Jr.

ORB #4 Rdg DBrinkan Vice President and General Counsel DEisenhut RDiggs Philadelphia Electric Company OELD GGears 2301 Market Street CMiles RIngram Philadelphia, Pennsylvania 19101 LHarmon Gray File ACRS-10

Dear Mr. Bauer:

TBarnhart-4 During the current unscheduled maintenance outage for the Peach Bottom Atomic Power Station, Unit 3, ultrasonic inspections of the reactor pressure vessel jet pump instrument nozzle seals revealed a number of unacceptable crack indications. You took corrective actions to repair these nozzle seals and reported the results of the inspections, analyses, and repair procedures in a letter to the :mC dated June 20, 1984.

Based upon a meeting and related discussions with your staff and our review of your submittal, we find the corrective actions you have taken are acceptable. With the issuance of this letter, plant restart is hereby authorized for continued operation until the start of the next refueling outage.

A copy of our Safety Evaluation is enclosed.

Sincerely, LU t~4n Y Geor W. Rivenbark, Acting Chief Operating Reactors Branch #4 Division of Licensing

Enclosure:

Safety Evaluation cc w/ enclosure:

See next,rge

  • See p>evious white fo,r concurrences.

6 ORB #4:DL '

ORB #4:DL AD:MCET:DE A:hDL Ps;cf GRivenbark

  • WJohnston
  • Gla.nEs 6,

4 6/ 20'84 6/ 20'84 6//f/84 h

DO O

S

Docket No. 50-278 DISTRIBUTION Docket File EJordan NRC PDR JNGrace L POR WJones Mr. Edward G. Bauer, Jr.

ORB #4 Rdg DBrinkan Vice President and General Counsel DEisenhut RDiggs Philadelphia Electric Company.

OELD GGears 2301 Market Street CMiles RIngram Philadelphia, Pennsylvania 19101 LHarmon Gray File ACRS-10

Dear Mr. Bauer:

TBarnhart-4 i

During the current unscheduled maintenance outage for the Peach Bottom Atomic Power Station, Unit 3, ultrasonic inspections of the reactor pressure vessel jet pump instrument nozzle seals revealed a number of unacceptable crack indications. You took corrective actions to repair these nozzle seals and reported the results of the inspections, analyses, and repair procedures in a letter to the NRC dated June 20, 1984.

Based upon a meeting and related discussions with your staff and our review of your submittal, we find the corrective actions you have taken are acceptable. Therefore, based upon the acceptability of your corrective actions, plant restart is authorized.

1 A copy of our Safety Evaluation is enclosed.

Sincerely, George W. Rivenbark, Acting Chief Operating Reactors Branch #4 Division of Licensing

Enclosure:

l 3.

Safety Evaluation cc w/ enclosure:

Sae next page

  1. 4:DL OR 4 AD C DE AD:0R:DL sicf GRi bark WJohnston Glainas 6

84 6/ t7/84 6/J.o/84 6/ /84

Philadelphia Electric Company ccw/ enclosure (s):

Eugene J. Bradley

__ Regional Radiation Representative Philadelphia Electric Company Assistant General Counsel EPA Region III 2301 Market Street Curtis Building (Sixth Floor)

Philadelphia, Pennsylvania 19101 6th and Walnut Streets Philadelphia, Pennsylvania 19106 Troy B. Conner, Jr.

1747 Pennsylvania Avenue, N.W.

M. J. Cooney, Scerintendent Washington, D. C.

20006 Generation Division - Nuclear Philadelphia Electric Ce nany 2301 Market Street Philadelphia, Pennsylvania 19101 Thomas A. Deming, Esq.

Ass lstant Attorney General Department of Natural Resources Annapolis, Maryland 21401 Philadelphia Electric Company ATTN: Mr. R. Fleishmann Peach '30ttom Atomic Power Station Mr. R. A. Heis. Coordinator Delta, Pennsylvania 17314 Pennsylvania S, ate Clearinghouse Governor's Office of State Planning Albert R. Steel, Chairman and Development Board of Supervisors P. O. Box 1323 Peach Bottom Township Harrisburg, Pennsylvania 17120 R. D. #1 Delta, Pennsylvania 17314 Allen R. Blough U.S. Nuclear Regulatory Commission Thomas M. Gerusky, Director Office of Inspection and Enforcement Bureau of Radiation Protection Peach Bottom Atomic Power Station Pennsylvania Department of P. O. Box 399 Environmental Resources Delta, Pennsylvania 17314 P. O. Box 2063 Harrisburg, Pennsylvania 17120 ilr. Thomas E. !!urley, Regi.onal Administrator U. S. Nuclear Regulatory Connission, Region I Office of Inspection and Enforcement 631 Park Avenue King of Prussia, Pennsylvania 19406

.