ML20151D295

From kanterella
Jump to navigation Jump to search
Forwards Cask Drop Analysis Yankee Nuclear Power Station Spent Fuel Pool
ML20151D295
Person / Time
Site: Yankee Rowe
Issue date: 03/31/1988
From: Papanic G
YANKEE ATOMIC ELECTRIC CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML20151A373 List:
References
FYR-88-44, NUDOCS 8804140117
Download: ML20151D295 (1)


Text

'

t TeCphone (017) 872 C100 TWX 710-3D-7619 YANKEE ATOMIC El.ECTRIC COMPANY A-YNbs

"*'c"

"J' m '"9 "" m ^ * *'c h "'c "* 0 "0 '

March 31, 1988 FYR 88-44 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

References:

(a) License No. DPR-3 (Docket No. 50-29)

(b) Letter YAEC to USNRC, dated January 15, 1988

Subject:

Spent Fuel Pit Analysis

Dear Sir:

In Reference (b), Yankee identified that an analysis was performed to determine the consequences of a hypothetical cask drop into the spent fuel pit. Attached per your request, is the report which describes the analysis and its conclusion that there is ample margin against pool leakage from a cask drop.

We trust that you will find this report satisfactory. However, if you have any questions, please contact us.

Very truly yours, YAhTEE ATOMIC ELECTRIC COMPANY

~ x G. Pa

, Jr Senior Project Engineer Licensing GP/25.522 f

Attachment cc: USh1C Region I USNRC Resident Inspector, YNPS 00 I

P

\\ \\

1 d