ML20151A285

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-445/88-43 & 50-446/88-39 on 880613-16.No Violations or Deviations Noted
ML20151A285
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 07/11/1988
From: Warnick R
NRC OFFICE OF SPECIAL PROJECTS
To: Counsil W
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
Shared Package
ML20151A289 List:
References
NUDOCS 8807190319
Download: ML20151A285 (4)


See also: IR 05000445/1988043

Text

'

y_lll%

>

.

,

In Reply Refer To:

Dockets:

50-445/88-43

50-446/88-39

DOCUMENT CONTAINS

SAFEGUARDS INFORMATION

TV Electric

ATTN: Mr. W. G. Counsil

Executive Vice President

400 North Olive, L.B. 81

Dallas, Texas 75201

Gentlemen:

This refers to the inspection conducted by Mr. R. A. Caldwell of this office

during the period June 13-16, 1988, of activities authorized by RC Construction

Permits CPPR-126 and CPPR-127 (Units 1 and 2) for Comanche Peak Sceam Electric

Station, and to the discussion of our findings with members of your staff at

the conclusion of the inspection.

The inspection covered certain areas of your physical security program. Within

these areas, the inspection consisted of selective examination of procedures

and representative records, interviews with personnel, and observations by the

NRC inspector.

The areas inspected and inspection findings are documented in

the enclosed inspection report.

Within the scope of the inspection, no violations or deviations were

identified.

We have also examined actions you have taken with regard to previously

identified inspection findings.

The status of these ;tems is identified in

paragraph 2 of the enclosed report.

The material enclosed herewith contains Safeguards In#ormation as defined by

10 CFR Part 73.21 and its disclosure to unauthorized individuals is prohibited

by Section 147 of the Atomic Energy Act of 1954, as amended.

Therefore, the

material, with the exception of the report cover page which is an inspection

summary, will not be placed in the Public Document Room.

Should you have any questions concerning this inspection, we will be pleased to

discuss them with you.

,

ENCleSURE CONTAINS

Sincerely,

WMNDS INFORMATimi

$o

ifW1 SEPARAil0N I':

-#A

PAGE IS DECONTRCLLL)

  1. 8'

ORIGINAL SIGNED BY:

oo

$$

NMENT WAINS

R. F. Warnick, Assistant Director

os

SAFEGUARDS INFORMATION

f r Inspection Programs

-u

Comanche Peak Project Division

$8

Office of Special Projects

Sg

Enclosure:

(see next age)

o)o

[io

0)4U

RIV.PSS:RPS(

C:

C:RPB-

D:0g

AD:IP:CPPD:0SP

RACaldwell: ;b

Everett

BMurray

RLBangart

RFWarnickRh ' \\

~1/f/88

}/y/88

'\\

/88

flof/88

7/ 8/88

&}

J

4

-

.,.

-

..

.

,

.

TV Electric

-2-

Enclosure:

t

Appendix - NRC Inspection Report

50-445/88-43

50-446/88-39

cc w/ summary page only:

TV Electric

Bureau of Radiation Control

ATTN:

Roger D. Walker

State of Texas

Manager, Nuclear Licensing

1100 West 49th Street

Skyway Tower

Austin, TX 78756

400 North Olive Street, L.B. 81

Dallas, TX 75201

Juanita Ellis

CYGNA Energy Services

President - CASE

ATTN: Nancy H. Williams

1426 South Polk Street

Suite 390

Ds11as, TX 75224

2121 N. California Blvd.

Walnut Creek, CA 94596

Susan M. Theisen

GDS Associates, Inc.

Assistant Attorney General

Suite 720

Environmental Protection Division

1850 Parkway Place

P.O. Box 12548, Capitol Station

Marietta, GA 30067-8237

Austin, TX - 78711-2548

U.S. Nuclear Regulatory Commission

Worsham, Forsythe, Sampels

ATTN:

Peter Bloch

and Wooldridge

Administrative Judge

ATTN:

Robert A. Wooldridge, Esq.

Washington, D.C.

20555

2001 Bryan Tower, Suite 2500

Dallas, TX

75201

Oak Ridge National Laboratory

TV Electric

ATTN: Elizabeth B. Johnson

ATTN: Momer C. Schmidt

Administrative Judge

Director of Nuclear Services

P.O. Box X, Building 3500

Skyway Tower

Oak Ridge, TN 37830

400 N. Olive Street, L.B. 81

Dallas, TX 75201

Dr. Kenneth A. McCollom

Stone & Webster Engineering Corp.

1107 West Knapp

ATTN:

R. W. Ackley, Project Manager

Administrative Judge

Comanche Peak Steam Electric Station

Stillwater, OK 74075

P.O. Box 1002

Glen Rose, Texas 76043

Dr. Walter H. Jordan

'!estinghours Electric Corporation

Administrative Judge

ATTN: Mr. J. L. Vota

881 West Outer Drive

P.O. Box 355

Oak Ridge, TN 37830

Pittsburgh, PA 15230

ENCt050AE CONTAINS

SAFEGUARDS INFORMATION

UPON SEPARATION THIS

PAGE IS DECONTROLLED

I

-

..

.

TV Electric

-3-

Anthony Z. Roisman, Esq.

Christic-Institute

Suite 600

ATTN:

Lanny A. Sinkin

1401 New York Avenue, N.W.

1324 N. Capitol Street

Washington, D.C.

20005

Washington, D.C.

20002

Billie Pirner Garde, Esq.

Orrick, Herrington & Sutcliffe

Government Accountability Project

ATTN:

David R. Pigott, Esq.

Midwest Office

600 Montgomery Street

104 East Wisconsin Avenue

San Francisco, CA 94111

Appleton, WI 54911

Spiegel & McDiarmid

Newman & Ho'tzinger, P.C.

ATTH:

Robert Jablon

ATTN: Jack R. Newman, Esq.

Bonnie S. Blair

1615 L. Street., N.W., Suite 1000

1350 New York Avenue, N.W.

Washington, D.C.

20036

Washington, D.C.

20005-4798

Senior Citizens Alliance of Tarrant

Fulbright & Jaworski

County, Inc.

ATTN: Joseph F. Fulbright

ATTN:

George A. Parker, Chairman

1301 McKinney Street

Public Utility Committee

Houston, TX 77010

6048 Wonder Drive

Fort Worth, TX 76133

TU Electric

Heron, Burchette, Ruckert, & Rothwell

ATTN: Jack Redding

ATTN: William A. Burchette, Esq.

c/o Bethesda Licensing

Counsel for Tex-La Electric

3 Metro Center, Suite 610

Cooperative uf Texas

Bethesda, MD 20814

Suite 700

1025 Thomas Jefferson St., N.W.

Washington, D.C.

20007

bec:

Copy of entire report:

RIV Security File

P. A. Starcher, RSGB/NRR

R. D. Martin, RA

R. L. Bangart, DRSS

Security Inspector

Chief, RPB

SEPS:RPB File

G. F. Sanborn, E0

R. F. Warnick, AD:CPPD:0SP

i

ENCLOSURE CONTAINS

i

l

SAFEGUARDS INFORMATION

UPON SEPARATION THIS

PAGE IS DECONTROLLED

i

..

-

-

.

.

.

..

.

TV Electric

-4-

bcc:

RIV - Letter and. Inspect. ion Summary only w/766:

-DRP

RIV File

MIS

Lisa Shea, RM/ALF

RSTS Operator

Site Reading

R. E. Hall, DRSS

bec:

RIV - Letter and Inspection Summary only w/out 766:

'DMB IE-04

DRS

S. Ebneter/JAxelrad

A. Vietti-Cook

F. Miraglia

J. Partlow

J. Taylor

C. Grimes

J. Lyons

M. Malloy

.E. Jordan

B. Hayes

J. Gilliland

P. McKee

J. Moore, OGC

OSP Reading (Mail 7-D-24)

CPPD Reading (HQ) (Mail 7-H-17)

ENCLOSURE CONTAINS

SAFEGUARDS INFORMATION

UPON SEPARATION DilS

PAGE IS DECONTROLLED

- . . .

-

-

.-

- . . .

-

-.

.- .

_ _ _ .