Responds to IE Bulletin 79-18, Audibility Problems Encountered W/Evacuation of Personnel from High-Noise Area. Amplifier Added to Circuitry to Increase Alarm Vol.Design Change to Install Visual Evacuation Signal Being Formulated
ML20150F340
Person / Time
Site: North Anna 
Issue date: 09/24/1979
From: Stallings C
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
NUDOCS 7910100053
Download: ML20150F340 (1)


Text

.

(.

l l

l VamonwsA Ex.acrmiC AND POWHm COMPAMY l

Hacunown.Vamotu sA unub

, fj 3,

6

o g

.}

September 24, 1979 c.n G3 Mr. James P. O'Reilly, Director Serial No. 655 Office of Inspection and Enforcement P0/RKriscj

(

U. S. helear Regulatory Commission Docket Nos. 50-338 Region II y

101 Marietta Street, Suite 3100 Atlanta, Georg"ta 30303 License Nos. NPF-4

Subject:

IE Bulletin 79-18 l

Dear Mr. O'Reilly:

I f

This is in response to IE Bulletin No. 79-18. " Audibility Problems Encountered l

on Evacuation of Personnel From High-Noise Areas" for North Anna Power Station Unit No. 1.

1.

During the preoperational testing of the station communications system, it was discovered that the fire and evacuation alarms were not loud enough to be heard throughout the entire plant. As a result, an amplifier was added to the circuitry to increase the volume of these alarms. Current alarm systems and evacuation announcement systems have been determined clearly audible in all plant areas except the emergency diesel generator rooms when the diesels are operating.

2.

Because of their function, the diesel generator rooms are not normally habitable. Also, during a station evacuation, personnel accountability l

1s accomplished through use of approved emergency plan implementing procedures.

A design change to install a visual evacuation signal in the diesel generator rooms is presently being formulated. When this design change is finalised, a time schedule for its implementation will be submitted.

i I