.,,,.,M George S. Thomas Vice President Nuclear Production PLA30c Servios of New Hampshire New Hampshire Yankee Division NYN-88037 s
March 30, 1988 United States Nuclear Regulatory Conanission Washington, DC 20555 Attention:
Document Control Desk
Reference:
(a) Facility Operating License NPF-56, Censtruction Permit CPPR-136, Docket Nos. 50-443 ara 50-444 (b)
PSNH Letter (SBN-1008), dated April 22, 1986, "NUREG-0737, Task II.B.3, Post-Accident Sampling System Criterien (10) - Accuracy, Range and Sensitivity", J. DeVincentis to V. S. Noonan
Subject:
NUREG-0737, Task II.B.3 - Criterloa (10)
Gentlemen:
Reference (b) stated that Seabrook Station would employ the Fluoroborate Selective Ion Electrode method for post-accident.,cron analysis. This analysis method was recommended by Exxon Nuclear Idaho Company, Inc., in a 1981 report for the NRC.
New Hampshire Yankeo (NHY) has subsequently and successful lab-oratory experience with boron analysis by Mannitol Titrations.
This method was discussed in the Exxon Nuclear report, but it was not specifically recommended dua to possible maintenance difficulties.
Experience at Seabrook Station indicates Mannitol Ticrations to be a superior method because of operational simplicity and consistently reliable results.
NHY intends to revise the preferred method for post-accident boron analysis to be Mannitol Titrations.
A discussion of this method is presented in the enclosure.
Should you have any questions regarding this information, please contact Mr. Warren J. Hall at (603) 474-9521, extension 4046.
Very truly your6, geYTomas 6
Enclosure C
1800404020Y68'0330'.
l' h
~
PDR ADOCK 05000443 i
P DCD P.O. Som 300. Seabrook, NH 03874. Telephone (t,03) 474 9574
.,4 4,
Unit;d Sectcs Nuclsar R:gulatory Concission NYN-88037 Attontion:
Document Control Desk Page 2 cc:
Mr. Victot Nerses, Project Manager Project Directorate I-3 Division of Reactor Projects United States Nuclear Regulatory Commission Washington, DC 20555 Mr. William T. Russell Regional Administrator United States Nuclear Regulatory Commission Region 1 425 Allendale Road King of Prussia, PA 19406 Mr. Antone C. Cerne KRC Senior Resident Inspector Seabrook Station Seabrook, NH 03874
f
. e -.:-
ENCLOSURE TO NYN-88037 Boron by Mannitol Titrations Boron concentration in liquid samples is determined using a Metrohm Titroprocessor unit to do Mannitol Titrations.
This procedure was devel-oped for the range of 1 ppm to 10 ppm Boron; higher concentrations may by determined by dilution.
Boron standards were prepared in a post-accident reactor coolant matrix specified in NUREG-0737, II.B.3, and diluted 500:1.
The matrix consisted of the following:
20 ppm K+
as KI, KNO3 10 ppm Cl-as NH Cl 4
2 ppm Li+
as LiOH 250ppmCg+
La(N3)3 6"2o as CsNO 5 ppm La+
as 3
40 ppm I 2 as KI 10 ppm Ba+
as Ba(NO )
3 5 ppm Ce+
(NH )2 e(NO )
as (NH )2 Ce(h0 )63 6' E Cl 4
3 6.4 ppm NH +
as 4
4 4
157.8 ppm NO3 KNO, CsNO, La(NO )3 *6H 0, Ba(NO )2, (NH )3 Ce(NO )6 as 3
3 3
2 3
4 3
Results of the testing determined that the method of analysis had no affect on the accuracy of the analysis.