l MATERIALS LICENSE Amendment No. 08 Pursuant to the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Pub lic Law 93 -438), and Title 10.
Code of Federal Regulations, Chapter I, Parts 30,31,32,33,34,35,40 and 70, and in reliance on statements and representations p
heretofore made by the lidensee, a license is hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct, p
source, and specia' anuclear material designated below: to use such material for the purpose (s) and at the place (s) designated below;to n
3 deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). This R
M license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is i subject to all applicable rules, regulations and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any E
g conditions specified below.
In accordance with letter dated l
April 27, 1988, if 1-
- q Department of the Army
- 3. Ucense number SNM-244 is amended in i
.4 Materials Technology Laboratory its entirety to read as follows:
il l
q 2.
Arsenal Street e.
j Watertown, Massachusetts 02172-0001
- 4. Expiration date August 31, 1992 g
- 5. Docket or 3
Reference,No.
070-00263
% 6. Byproduct, source, and/or
- 7. Chemical and/or physical
- 8. Maximum amount that licensee
${
special nuclear material form may possess at any one time
, under this license j
A. Enriched uranium A. Any y A. 8 grams B. Plutonium 239 B. Sealed sources' / it.
B.' Not to exceed q
g \\)3 ;
L80 grams per
!g
's
- source, 160 j
- s grams total C. Plutonium 239 C. Sealed sources C. 32 grams j
D. Plutonium 23S D. Sealed sources D. 0.16 micrograms i
j 79 J, i i j.I M_. s..
!1 s 9.
cthorized use p
pr l1 g.
1 A.
For use in neutron detectors.
E 1
B.
For use in instrument calibration.
5 l
C.
For use in neutron filters, j
D.
For use as alpha scurce standards.
1 i
1 CONDITIONS 1
i 'l 1
- 10. Licensed material shall be used only at U.S. Army Laboratory Command, Materials l'I l
Technology Laboratory, Watertown, Massachusetts.
1 1
11.
A.
Licensed material shall be used by, or under the supervision of. John Antal, 1
Forrest Burns, Laurence Jennings, Louis Farese, James McCauley, Robert 1
Fitzpatrick, Peter F. Cornetta or Lucas M. Demetroulakos.
1 j
B.
The Radiation Safety Officer for this license is Peter F. Cornetta.
! 12. A(1) Each sealed source or detector cell acquired from another person and 1
containing licensed material, other than hydrogen 3, with a half-life y
I 1
greater than 30 days and in any form ottar than gas shall be tested for 1
contamination and/or leakage before use.
In the absence of a certificate l
from a transferor indicating that a test has been made within 6 months Mt.10, l
before the transfer, a sealed source or detector cell received from b
another person shall not be put into use until test e l
8507130390 880610 uFFICIAl. RECORD COPY" i QifTil NON PDR TK5DiUsDQQraTasdr.FCT2tWigsUjissmassumai0rmanssid
e q
I Lkense number h
i SNM-244 5
(
MA'TERI LS LICENSE I
oocke or aeterence number l
SUPPLEMENTARY SHEET 070-00263 q
y g
Amendment No. 08 y
g
{
l (12. continued)
CONDITIONS l
(2) Notwithstanding the periodic leak test required by this condition, any y
g licensed sealed source or detector cell is exempt from such leak tests p
I when the source or detector cell contains 100 microcuries or less of beta p
i and/or gama emitting materials or 10 microcuries or less of alpha l
emitting material.
l l
(3)Exceptforalpt: m "es, the periodic leak test required by this condi-l tion does not app;,, W aaled sources that are stored and not being used.
p l
The sources excepted from this test shall be tested for leakage before p
4 any use or transfer to another person unless they have been leak tested h
j within 6 months before the date of use or transfer.
l li B.
Each sealed source or detector cell fabricated by the licensee shall be inspected and testad for construction defects, leakage, and contamination y
M prior to use or transfer as a sealed source or detector cell.
If the M
inspection or test reveals any construction defects or 0.005 microcurie h
l or greater of contamination, the source shall not be used or transferred
(
q as a sealed source or detector cell until it has been repaired, decontami-p g
nated and retested, p
i d
C.
Each sealed source containing licensed material, other than hydrogen 3, h
l with a half-life greater than 30 days and in any form other than gas shall be tested for leakage and/or contamination at intervals not to l
q q
exceed 6 months except that each source designed for the purpose of g
4 emitting alpha particles shall be tested at intervals not to exceed 3 pl q
months.
N h
i 5
D.
The test shall be capable of detecting the presence of 0.005 microcurie h
f of radioactive material on the test sample.
The test sartple shall be l
taken from the sealed source or detector cell or from the surfaces of the p
/
device in which the sealed source or detector cell is permanently or p
i semipermanently mounted or stored on which one might expect contamination p>
to accumulate.
Records of leak test results shall be kept in units of i
microcuries and maintained for inspection by the Commission.
Records may l
be disposed of following Comission inspection.
l 4
6
- l E.
If the test required by Subsection A, or C. of this condition reveals the p
presence of 0.005 microcurie or more of removable contamination, the h
licensee shall immediately withdraw the sealed source or detector cell from use and shall cause it to be decontaminated and repaired or to be disposed of in accordance with Commission regulations. A report shall be l
l filed within 5 days of the date the leak test result is known with the p
U. S. Nuclear Regulatory Commission, Region I, ATTN:
Chief, Nuclear Materials Safety and Safeguards Branch, 631 Park Avenue, King of Prussia, Pennsylvania 19406, describing the equipment. involved, the test results, and the corrective action taken.
l p
c A
GU A c
3 4
Lkena numbe r l
SNM-244 MATERIALS LICENSE l
SUPPLEMENTARY SHEET 070-00263 1
q Amendment No. 08 p
i p
I (continued)
CONDITIONS I
r l
13.
Sealed sources containing licensed material shall not be opened.
14.
Except as specifically provided otherwise in this license, the licensee shall N
conduct its program in accordance with the statements, representations, and
)
N procedures contained in the documents including any enclosures, listed below.
l N
The Nuclear Regulatory Comission's regulations shall govern unless the state-l ments, representations and procedures in the licensee's application and corre-p p
g spondence are more restrictive than the regulations.
N N
4 A.
Application dated May 27, 1987 l
l B.
Letter dated April 27, 1988 l
d M
8 4
4 4
1 4
a l
t a
i a
d 5
R p
a 5
i>
- i A
p W
d dl n
N l
5 W
d W
4 W'
d s
i t
q For the U.S. Nuclear Regulatory Commission l
n 10 JU 988 4
D By John D. Kirwedtn p
l ate Nuclear Materials Safety and q
Safeguards Branch, Region I
(
King of Prussia, Pennsylvania 19406 E
I I
N TXMkMKKikHEKKLMdHMRiTC&~IGNYMsWRTHD6scaMircDsMisMirJrx;r:rgm
<