._=.

March 11,1988 Docket No. 50-458 Mr. James C. Deddens SeniorVicePresident,(RBMG)

Gulf States Utilities P. O. Box 220 St. Francisville, LA 70775 i

ATTN: Nuclear Licensing

Dear Mr. Deddens:

SUBJECT:

NRC BULLETIN 87-01, "THINNING OF PIPE WALLS AT l

j NUCLEAR POWER PLANTS

(

1 4

t On July 9, 1987 NRC Bulletin 87-01 was issued and requested that licensees l

l sutoit infomation concerning their programs for monitoring the thickness of pipe walls in high-energy single-phase and two-phase carbon steel pipinc systems. Culf States Utilities Corpany providad its respense to the Bulletin 1

in a letter dated September'11, 1987.

9 J.

I The staff has reviewed ycur response and concludes t'at no further plant j

specific action with respect to NRC Bulletin 07-01 is required at this tire.

y Sincerely, I

1 Walter A. Paulson, Project Marager i

Project Directorate - !Y Division of Reactor Projects - III, t

j IV, V and Special Projects

(

cc: See next page I

1 I

DISTRIBUTION.

I Doctet me-NRC PDR Local POR PD4 Reading 1

DR4A/J. Collins J. Calvo P. Noonan W. Paulson OGC-Rockville E. Jordan J. Partlow ACRS (10) l PD4 Plant File j

i i

i i

j i

l Y

)

PDA/ lap (

PD PM PD4/0 j

PNoonanQ WPaulson:sr JCalvo 03/4/88 03/q/88 03/// /88

[BRAMM SS8%he 1

't' March 11,1988

.o Docket No. 50-458 Mr. James C. Deddens SeniorVicePresident,(RBNG)

Gulf States Utilities P. O. Box 220 St. Francisville, LA 70775 ATTN: Nuclear Licensing

Dear Mr. Deddens:

SUBJECT:

NRC BULLETIt! 07-01, ' THINNING OF PIPE WALLS AT NUCLEAR POWER PLANTS On July 9,1987 NRC Bulletin 87-01 was issued and requested that licensees submit infnrnatinn cencerning their programs for monitoring the thickness of pipe walls in high-energy single-phase and two-phase carbon steel piping systems. Culf States Utilities Cenpany provided its response to the Bulletin in a letter dated September 11, 1967.

The staff has reviewed yrur response and concludes that no further plant specific action with respect to NRC Bulletin 07-01 is required at this tire.

Sincerely, Walter A. Paulson, Project Marager Project Directorate - !Y Division of Reacter Projects - III, IV, Y and Special Projects cc: See next page DISTRICUTION Docket File NRC PDR Local PDR PD4 Reading DR4A/J. Collins J. Calvo P. Noonan K. Paulson OGC-Rockville E. Jordan J. Partlow ACRS(10)

PD4 Plant File FDA/LAS PD PF PD4/D FNoonan WPaulsontsr JCalvo 03/Ct/88 03/q/88 03/// /88

I o

Mr. James C. Deddans Gulf States Utilities Corpany River Berd Nuclear Plant cc:

Trey B. Conner, Jr., Esq.

Mr. J. E. Booker Conner and Wetterhahn Manager-River Bend Oversight 1747 Pennsylvania Avenue, NW P. O. Box 2951 Washington, D.C.

20006 Beaumont, TX 77704 Mr. William H. Spell, Administrator Director - Nuclear Licensing Fuclear Energy Division Gulf States Utilities Company Office of Environnental Affairs P. O. Box 220 P. O. Box 14690 St. Francisv111e, LA 70775 Baton Rouge, Louisiana 70898 Richard M. Troy, Jr., Esq.

Assistant Attorney General in CFerge Mr. J. David McNeill, I!!

State of Louisiana Department of Justice William G. Davis, Esq.

734 Loynla Avenue Departr*rt of Justice New Orleans, Louisiare 70112 Attornay General's Office 7434 Perkins Road Resident inspector Baton Rouge, Louisiana 70808 P. O. Box 1051 St. Francisville Louisiana 70775 H. Anne P1ettinger 3456 Villa Rose Drive Gretchen R. Rothschild-Reinike Baton Rouge, Louiriana 70806 Louisianians for Safe Energy, Inc.

2100 Broadway Street New Orleans, Louisiana 70118-5462 President of West Feliciana Police Jury Regional Administrator, Region IV P. O. Box 1971 U.S. Nuclear Regulatory Cerr'ssion St. Francisville, Louisians 70776 Office of Executive Director for Operations Mr. Frank J. Uddo 611 Ryan Plaza Drive. Suite 1000 Uddo & Porter r

Arlington, Texas 76011 6305 Elysian Fields Avenue Suite 400 Philip G. Harris New Orleans, Louisiana 70122 Cajun Electric Power Corp. Inc.

I 10719 Airline Highway P. O. Box 15540 Baton Rouge, LA 70895