ML20150C049

From kanterella
Jump to navigation Jump to search
Forwards QA Program Insp Rept 99900014/78-02 on 780821-24 & Notice of Deviation
ML20150C049
Person / Time
Issue date: 09/08/1978
From: Potapovs U
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Mueller P
CRANE MIDWEST FITTING (DIV. OF CRANE CO.)
Shared Package
ML20150C041 List:
References
REF-QA-99900014 NUDOCS 7811100064
Download: ML20150C049 (2)


Text

bs Mcv UNITED STATES q

NUCLEAR REGULATORY COMMISSION

(( '

o REGION IV

'5 611 RYAN PLAZA DRIVE, SUITE 1000 ARLINGTON, TEXAS 76011 8

. o, s*****/

04 SEP 1976 1

Docket No. 99900014/78-02 Crane Midwest Fittings Attn: Mr. R. A. Mueller General Manager 1450 South Second Street St. Louis, Missouri 63104 Gentlemen:

This refers to the QA Program inspection conducted by Mr. H. W. Roberds i

of this office on August 21-24, 1978, of your facility at St. Louis, Missouri, associated with the manufacture of fittings and to the discussions of our' findings with Mr. D. F. Betz and members of your staff at the conclusion of the inspection.

This inspection was made to confirm that, in the areas inspected, your

^

QA Pronram is being effectively implemented. The inspection effort is not designed to assure that unique quality requirements imposed by a customer are being implemented; nor to assure that a specific product, component or service provided by you to your customers, is of acceptable quality.

As you know, the NRC requires each of its licensees to assume full responsibility for the quality of specific products, components or -

services procured from others. You should therefore not conclude that the NRC's inspection exempts you from inspections by an NRC licensee or his agents nor from taking effective corrective action in response to their findings.

Areas examined and our findings are discussed in the enclosed report.

Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.

During the inspection it was found that the implementation of your QA Program failed to meet certain NRC requirements. The specific findings and references to the pertinent requirements are identified in the enclosures to this letter.

Please provide us within thirty (30) days of your receipt of this report a written statement containing, (1) a description of steps that have been or will be taken to correct these items, (2) a description of steps that have been or.will be taken to prevent recurrence, and (3) the'date your corrective actions and preventive measures were or will be completed.

781110'00 @

Crane Midwest Fittings ~In accordance with Section 2.790 of the Commission's " Rules of Practice,"'

Part 2. Title 10, Code of Federal Regulations, a copy of this letter with enclosure and your-reply, together with the enclosed inspection report will be placed in the Comission's Public Document Room.

If this report contains any information that you believe to be proprietary, it is necessary that you make a written application within thirty (30) days to this office to withhold such information from public disclosure. Any such application must-include a full statement of the reasons on the basis of which it is claimed that the information is proprietary, and should be prepared so that proprietary infor-mation identified in the application is contained in a separate part of the document.

If we do not hear from you in this regard within the specified

~

period, the report will be placed in the Public Document Room.

Should you have any questions concerni.ng this inspection, we will be pleased to discuss them with you.

l Sincerely, DJ

?.mO-.- _.

Uldis Potapovs, Chief Vendor Inspection Branch

Enclosures:

1.

Notice of Deviation 2.

Inspection Report No. 99900014/78-02 4

1 2'--

e w

vw: