ML20150A928

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Repts 50-454/78-07 & 50-455/78-07 on 780930 & Notice of Violation
ML20150A928
Person / Time
Site: Byron  Constellation icon.png
Issue date: 08/31/1978
From: Heishman R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Brian Lee
COMMONWEALTH EDISON CO.
Shared Package
ML20150A931 List:
References
NUDOCS 7810190219
Download: ML20150A928 (2)


See also: IR 05000454/1978007

Text

- f Dlb

-.

.g

jt #N 4 UNITED STATES

fr ..1 NUCLEAR REGULATORY COMMISSION '

1

lt* , 7'T f j

fj

REGloN 111

799 ROOSEVELT RoAo  !

. c.: * j c LEN E LLYN, IL LINoiS 60137

g ....* .

AUG 31198~

Docket No. 50-454

Docket No. 50-455

Cot::monwealth Edison Company

ATTN: Mr. Byron, Lee, Jr.

Vice President

P. O. Box 767

Chicago, IL 60690

Gentlemen:

This refers to the inspection conducted by Messrs. J. E. Konklin,

K. R. Naidu, G. F. Maxwell, J. H. Neisler, and H. M. Westcott of

this office on August 8-10, 1978, of activities at Byron Nuclear

Generating Station, Units 1 and 2, authorized by NRC Ccrstruction-

Permits No. CPPR-130 and No. CPPR-131 and to the discussion of our

findings with Mr. Sorensen and others of your staff at tne conclu-

sion of the inspection.

..

The enclosed copy of our inr . tion report identifies areas examined-

during the inspection. Within these areas, the inspection consisted

of a selective examination of procedures and representative records,

observations, and interviews with personnel.

During this inspection, certain of your activities. appeared to be

in noncompliance with NRC requirements, as described in the enclosed

Appendix A.

This notice is sent to you pursuant to the provisions of Section

2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Code of

Federal Regulations. Section 2.201 requires you to submit to this

office within tnirty days of your receipt of this notice a written

statement or explanation in reply, including f or each item of non-

compliance: (1) corrective action taken and the results achieved;

(2) corrective action to be taken to avoid further noncompliance;

and (3) the date when full compliance will be achieved.

In accordance with Section 2.790 of the NRC's " Rules of Practice,"

Part 2, Title 10, code of Federal Regal:tions, a copy of this letter,

the enclosures, and your response to this 2atter will be placed 1n

the NRC's Public Document Room, except as follows. If the enclo-

-

sures contain information that you or your contractors believe to be

..

~771019o319

o j

>

~ p,, , ,

- _ _ _ - - - _ _ _ - _ _ - _ _

. .,

. I

'

Commonwealth Edison -2- AUG3'1TR

Company

' '

. proprietary, you must apply in writing to this office, within twenty

days of your receipt of this letter, to withhold such information

from public disclosure. The application must include a full statement

of the reasons for which the information is considered proprietary,

and should be prepared so that proprietary information identified in

the application is contained in an enclosure to the application.

We will gladly discuss any questions you have concerning this

inspection.

Sincerely,

  • - Tf

1. F. Beishman, Chief

Reactor Construction and

Engineering Support Branch

Enclosures:

1. Appendix A Notite

l

of Violation ~

l 2. IE Inspection Reports

l No. 50-454/78-07

and No. 50-455/78-07

cc w/encls:

Gunnar Sorensen, Station

Superintendent

Central Files

/

Reproduction Unit NRC 20b

l /PDR

Local PDR

NSIC

TIC

Mr. Dean Hansell, Office

' .of Attonrey General

.

e

- _________.__.__mm__.__mo----