ML20150A738
| ML20150A738 | |
| Person / Time | |
|---|---|
| Site: | Millstone |
| Issue date: | 06/29/1988 |
| From: | Stolz J Office of Nuclear Reactor Regulation |
| To: | Northeast Nuclear Energy Co (NNECO) |
| Shared Package | |
| ML20150A741 | List: |
| References | |
| NPF-49-A-021 NUDOCS 8807080182 | |
| Download: ML20150A738 (5) | |
Text
- jpe %Q o
jo UNITED STATES g
[
o NUCLEAR REGULATORY COMMISSION j
t; wAsmNGTON O. C. 20555
"%*..../
NORTHEAST NUCLEAR ENERGY COMPANY, ET AL.*
DOCKET NO. 50-423 MILLSTONE NUCLEAR POWER STATION, UNIT N0. 3 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.21 License No. hPF-49 1.
The Nuclear Regulatory Comission (the Comission) has founo that:
The app (lication for amendment by Northeast Nuclear Energy Company, A.
et al.
the licensee) dated March 1, 1908, complies with the l
standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Comission's rules,and regulations sat forth in 10 CFR Chapter I; B.
The 'acility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.
There is reasonable assurance (i) that the activities authorized oy this amendment can be conducted without endangering tne he61th and safety of the public, and (ii) that such activities will be conducte'd in ccmpliance with the Comistion's regulations; l
0.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 I
of the Comission's regulations and all applicable requirements have l
been satisfied, l
- Northeast Nuclear Energy Conpany is authorized to act as agent and represent-l ative for the folicwing Owners: Central Maine Power Company, Central Vermont Public Servica Corporation, Chicopee Municipal Lightir.g Plant, City of l
Burlington, hrmont, Ccnnecticut Municipal Electric Light Company, Massachusetts l
Municipal Wholesale Electric Company, Montaup Electric Company, New Englano Power Company, The Village of Lyndonville Electric Department, Western l
Massachusetts Electric Company, and Vermont Electric Generation and l
Transmission Cooperative, Inc., and has exclusive responsibility ar,d control over the physical construction, operation and maintenance of the fucility.
l l
GGO70801G2 880624 I
PDR ADOCK 05000423 P
-2 2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and ptragraph 2.C.(2) of Facility Operating License No. NPF-49 is hereby amended to read as follows:
(2) Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendinent No. 21
, and the Environmental Protection Plan contained in Appendix B, both of which are attached hereto are hereby incorporated in.the license.
The licenses shall operate the 4
facility in accordance with the Technical Specifications and the Environmental Protection Plan.
3.
This license amendment is effcctive as of the date of its issuance.
FORTHENUCLEARREGULfTORYCOMMISSION
/.,
/)
1 Oh
. Stolz, Director Pro ect Directorate I-i ision of Re6ctor Projects I/II Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of Issuance:
June 29,1988 e
ATTACHMENT TO LICENSE AMENDMENT NO. 21 FACILTIY OPERATING LICENSE NO. NPF-49 DOCKET NO. 50-423 Replace the following page of the Appendix A Technical Specifications with the enclosed page. The revised page s identified by amendment number and a
contains vertical lines ir.dicating the areas of change. The correspondino overleaf page is provide's to maintain document completeness.
Remove Insert 6-6 6-6 f
1 4
I l
1 l
TABLE 6.2-1 MINIMUM SHIFT CREW COMPOSITION POSITION NUMBER OF INDIVIDUALS REQUIRED TO FILL POSITION i
MODE 1, 2, 3, or 4 MODE 5 or 6
~
SS 1
1 SRO 1
None R0 2
1 PE0 2
1 STA 1*
None SS Shift Supervisor with a Senior Operator license on Unit 3 SRO Individual with a Sentur Operator license on Unit 3 R0 Individual with an Operator license on Unit 3 PE0 Plant Equipment Operator (Non-licensed)
. The shift crew composition may be one less than the minimum requirements of
[
Table 6.2-1 for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> in order to accommodate unexpected absence of on-duty shift crew members provided immediate action is taken to restore the shift crew composition to within the minimum requirements of Table 6.2-1.
This provision does not permit any shift crew position to be unmanned upon shift change due to an oncoming shift crewman being late or absent.
During any absence of the Shift Supervisor from the control room while the unit is in MODE 1, 2, 3, or 4, an individual with a valid Senior Operator license shall be designated to assume the control room command function.
During any absence of the Shift Supervisor from the control room while the unit is in MODE 5 or F, an individual with a valid Senior Operator license or l
Operator license shall be designated to assume the control room command function.
l l
l
- The STA position may be filled by an on-shif t Senior Reactor Operator on'y if that Senior Reactor Operator meets the Shift Technical Advisor qualifica-tions of the Commission Policy Statement on Engineering Expertise on Shift.
MILLSTONE - UNIT 3 6-5
ADMINISTRATIVE CONTROLS 6.2.3 INDEPENDENT SAFETY ENGINEERING GROUP (ISEG)
FUNCTION 6.2.3.1 The ISEG shall include, as part of its function, examination of unit Operating characteristics, NRC issuances, industry advisories, Licensee Event Reports, and other sources of unit design and operating experience information, including units of similar design, which may indicate areas for improving unit safety. The ISEG shall make detailed recommendations for revised procedures, equipment modifications, maintenance activities, operations activities, or other means of improving unit safety to appropriate station / corporate management.
COMPOSITION 6.2.3.2 The ISEG shall be composed of at least four full-time personnel located on site to perform the functions described in 6.2.3.1 for Millstone Unit 3.
Each person shall have either:
(1) A bachelor's degree in engineering or related science and at least 2 years of professional level experience in his field, at least 1 year of which experience shall be in the nuclear field, or, (2) At least 10 years of professional level experience in his field, at least 5 years of which experience shall be in the nuclear field.
A minimum of 50% of these personnel shall have the qual.ifications specified in (1) above.
RESPONSIBILITIES 6.2.3.3 The ISEG shall be responsible for maintaining surveillance of unit activities to provide independent verification
- that these activities are performed correctly and that human errors are reduced as much as practical.
RECORDS 6.2.3.4 Records of activities perforr.ed by the ISEG shall be prepared and maintained, and quarterly reports of completed safety evaluations will be made to the Vice President - Nuclear and Environmental Engineering.
L2.4 SHIFT TECHNIG.Al ADVISOR 6.2.4.1 The Shif t Technical Advisor shall provide advisory technical support to the Shift Supervi:;or in the areas of thermal hydraulics, reactor engineering, and plant analysis with regard to the safe operation of the unit. The Shift Technical Advisor shall have a bachelor's degree or i
equivalent in a scientific or engineering discipline and shall have received specific training in the response and analysis of the unit for transients and accidents, and in unit design and layout, including the capabilities of instrumentation and controls in the control room.
l l
- Not responsible for sign-off function.
1 MILLSTONE - UNIT 3 6-6 Amendment No. 21