_.

Q Kt%

,,[

\\

UNITED STATES y

et g

NUCLE AR REGULATORY COMMISSION 3

.j WASHINGTON, D C. 205E5 s'%,,,,,*j February 22, 1988 Docket Nos. 50-327/328 Mr. S. A. White Manager of Nuclear Power Tennessee Valley Authority 6N 38A Lookout Place 1101 Market Street Chattanooga, Tennessee 37402-2801

Dear Mr. White:

SUBJECT:

TAYC0 IGNITER TEST RESULTS AND OPEPABILITY Re:

Sequoyah Nuclear Plant, Units 1 and 2 Sequoyah Nuclear Plant, Units 1 and 2, License DPR-77, License Condition 2.C.22.0, and License DPR-79, License Condition 2.C.16.h required the Tennessee Valley Authority (TVA) to perfont additional tests on the Tayco hydrogen igniters in order to demonstrate that the igniter will initiate combustion in a spray environ-ment such as that expected in the upper compartment of the ice condenser contain-ment.

In December 198?. the NRC staff issued NUREG-0011, Supplement No. 6 which documents the NRC staff safety evaluation of hydrocen control at the Sequoyah Nuclear Plant, Units 1 and 2.

The conclusions of NUREG-0011, 3upplement No. 6 state that subject to satisfactory resolution of the cpen item regarding the Tayco igniter, the staff finds the license conditions dealing with hyorogen control during postulated degraded core accidents to be satisfactorily resolved.

By letter dated October 11, 1983, NRC staff transmitted to TVA concerns regarding the proposed methodology and conduct of the Tayco ignitor test prograr:. By letter dated November 1, 1983, TVA provided HRC with a response to those concerns. NRC staff has evaluated the TVA response and the Tayco igniter test program test results and has found them to be acceptable.

Since the NRC staff has now resolved the Tayco igniter open item, License Conditions 2.C.22.D of DPR-77 and 2.C.16.h of DPR-79 have been fully satisfied.

8802260134 880222

)

PDR ADOCK 05000327 1

p PDR j

4-

_2 A staff safety evaluatien is also enclosed.

If you should have any questions regarding the above, please contact Mr. Thomas S. Rotella, NRC staff Sequoyah Project Manager at 301-492-0788.

Sincerely.

Original Signed by Gary G. Zech, Assistant Director for Projects TVA Projects Divieion Office of Special Projects

Enclosure:

As stated cc w/ enclosure:

See next page DISTRIBUTION Docket File NRC PDR Local PDR Projects Reading

5. Ebneter/J. Axelrad S. Richardson G. Zech B. D. Liaw K. Barr C. Jamerson T. Rotella DGC J. Rutberg F. Miraglia E. Jordan J. Partlow ACRS(10)

TVA-Rockville SON Reading File ec:

Plant Service list

TVA/LA OSP:T M

/P w

rson TSR V:as G

2/ V88 2/

68 2/af/88

lb 2

A staff safety evaluation is also enclosed.

If ycu should have any questions regarding the above, please contact Mr. Thomas S. Rotella, NRC staff Sequoyah Project Manager at 301-492-0788.

Sincerely, Original Signed by Gary G. Zech, Assistant Director for Projects TVA Projects Division Office of Special Projects

Enclosure:

As stated cc w/ enclosure:

See next page DISTRIBUTION Docket File NRC PDR Local POR Projects Reading

5. Ebneter/J. Axelrad S. Richardson G. Zech B. D. Liaw K. Barr C. Jamerson T. Rotella OGC J. Rutberg F. Miraglia E. ilordan J. Partlow ACRS(10)

TVA-Rockville SON Reading File cc:

Plant Service list

TVA/LA OSP:T M

D/P rson TSRo V:as G

2/ V88 2/

88 2/gf/88 l

i Mr. S. A. White Tennessee Valley Authority Sequoyah Nuclear Plant CC' General Counsel Regional Administrator, Pegion II Terressee Valley Authority U.S. Nuclear Regulatory Comission 400 West Sumit Hill Drive 101 Marietta Street, N.W.

E11 833 A1.lanta, Georgia 30323 Knoxville, Tennessee 37902 Resident Inspector /Sequeyah NP Mr. R. L. Gridley c/o U.S. Nuclear Regulatory Comission f

Tennessee Valley Authority 2600 Igou Ferry Road SN 1578 Lookout Place Soddy Daisy, Tennessee 37379 Chattanooga, Tennessee 37402-2801 Mr. Richard Kino Mr. H. L. Abercrombie c/o U.S. GA0 Tennessee Velley Authority 1111 North Shore Drive Sequoyah Nuclear Plant Suite 225, Box 194 P.O. Box 2000 Knoxville, Tennessee 37919 Soddy Daisy, Tennessee 37379 Tennessee Department of Mr. M. R. Harding Public Health Tennessee Valley Authority ATTN: Director, Bureau of Sequoyah Nuclear Plant Environmental Health Services P.O. Box 2000 Cordell Hull Building Soddy Daisy, Tennessee 37379 Nashville, Teanessee 37219 Mr. D. L. Willians Mr. Micheel H. Mobley, Director Tennessee Valley Authority Division of Radiological Health 400 West Sumit Hill Drive T.E.R.R.A. Building W10 P85 150 9th Avenue North Knoxville, Tennessee 37902 Nashville, Tenressee 37203 Ccunty Judge Dr. Henry Myers Science Advisor Hamilton County Courthouse Comittee on Interior Chattanooga, Tennessee 37402 and Insular Affairs' U.S. House of Fepresentatives Washington, D.C.

20515