4 u

u

,, s A

MATERIALS LICENSE Amendment No. 09 Pursuant to tite Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93-438), and Title 10, Code of Federal Regulations, Chapter 1, Parts 30,31,32,33,34,35,40 and 70, and in reliance on statements and representations !p heretofore made by the licensee, a license is hereby issued autnorizing the licensee to receive, acquire, possess, and transfer byproduct, lg source, and special nuclear material designated below; to use such material for the purpose (s) and at the place (s) designated below;to ;

deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). This license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is subject to all applicable rules, regulations and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any conditions specified below.

t-i Licensee i

In accordance with application dated i

3. fanuary 11, 1988, I-cense number Department of Transportation SNM-463 is amended in U.S. Coast Guard Academy its entirety to read as follows:
y,

,~

Department of Science Tc

'~'t ts #

J t-New London, Connecticut 06320

4. Espiration date May 31, 1990 f

t S. Docket or

  1. N' j'

Reference No.

070-00510

6. Byproduct, source, and/or
7. Chemical and/or physical V 6. Maximum amount that licensee form dmay possess at any one time special nuclear material c

i

,y

, u'nder this license I,

\\ h, x

, p;, 'A. 80 grams y

i; s

t A. Plutonium 239 A.' Encapsulated,cas Pu-Be 3 's 1

neutronsources(sy;e; }

h l

h ii b1 O

v

~

p~y, 9.

Authorized use

-m Wu. %

12.

Licensed material shall not be used in or on human beings, f

13. A(1) Any sealed source or detector cell specified in Item 7.A shall be tested for

'd leakage and/or contamination at intervals not to exceed 6 months. Any source M

or detector cell received from another person which is not accompanied by a

P1 certificate indicating that a test was performed within 6 months before the i

transfer shall not be put into use until tested.

i t

(2) Notwithstanding the periodic leak test required by this condition, any licensed sealed source or detector cell is exempt from such leak tests when the source or detector cell contains 100 microcuries or less of beta l

and/or gamma emitting material or 10 microcuries or less of alpha emitting material.

8802250101 080211

\\\\

1CIAl. RECORD COPY"Elg J

goWo gon

___-,-m,--m-m.m.msee-wwww

^

k

c r A

I Lkena n:rnber

)

' MATERIALS LICENSE S

463 l

SUPPLEMENTARY SHEET 0 0-00510 l

4 d

Amendment No. 69 y

I h

I (13. continued)

CONDITIONS h

I l

B.

Any sealed source or detector cell in storage and not being used need l

q not be tested. When the source or detector cell is removed from storage p

i for use or transfer to another person, it shall be tested before use or p

I

transfer, jn i

l C.

The test shall be capable of detecting the presence of 0.005 microcurie g

of radioactive material on the test sample.

If the test reveals the l

g presence of 0.005 microcurie or more of removable contamination, the p

I source or detector cell shall be removed from service and decontaminated,

%p 4

repaired, or disposed of in accordance with Comission regulations. A 4

report shall be filed within 5 days of the date the leak test result is h

l known with the U.S. Nuclear Regulatory Commission, Region I, ATTN:

Chief, l

g Nuclear Materials Safety and Safeguards Branch, 631 Park Avenue, King of y

(

Prussia, Pennsylvania 19406. The report shall specify the source involved, p

i the test results, and corrective action taken. Records of leak test j>

4 results shall be kept in units of microcuries and shall be maintained for j

inspection by the Comission. Records may be disposed of following gl q

Commission inspection, l

6

(

D.

Tests for leafage and/or contamination shall be performed by the licensee p

d or by other persons specifically licensed by the Comission or an Agree-j ment State to perform such services.

14. Sealed sources or detector cells containing licensed material shall not be l>,

opened or sources removed from detector cells by the licensee.

15.

Except as specifically provided otherwise in this license, the licensee shall h

4 conduct its program in accordance with the statements, representations, and f.h l

procedures contained in the documents including any enclosures, listed below, q'

The Nuclear Regulatory Comission's regulations shall govern unless the state-

!p d

ments, representations and procedures in the licensee's application and corre-lp

(

spondence are more restrictive than the regulations.

)E 4

l A.

Letter dated February 20, 1980 B.

Letter dated January 14, 1985 ql i

q C.

Letter dated November 3, 1986 4

D.

Letter dated June 10, 1987 4

i 4

l, 4

i l

4 i

(

4 For the U.S. Nuclear Regulatory Comission 4

(

Ortr,inni Signed By:

Date 11 FEB 1988 ey i

==

yl.

Nuclear Materials Safety and e

4 Safeguards Branch, Region 1 l

King of Prussia Pennsylvania 19406 kmxrxxxm.ma.u.a.us.raussaa.nxa.rx.axas.u.ma.rs.~mm