Text
_
- p2 Novy'o, NUCLEAR REGULATORY COMMISSION UNITED STATES h
ATLANTA F ER CENTER
'k',
8 ATLANTA GEORGIA 30303 61 FORSYTH STREET. SW. SUITE 23T85 4
April 30, 1997 1
MEMORANDUM T0:
Donald A. Cool, Director Division of Industrial and Medical Nuclear Safety Office of Nuclear Material Safety and Safeguards FROM:
Bruce S. Hallett, Director 1
Division of Nuclear Materials Safety Vy
SUBJECT:
REQUEST FOR COMMENTS ON THE IMPEP NON COMMON INDICATORS FOR THE SITE DECOMMISSIONING MANAGEMENT PLAN AND THE REGIONAL' FUEL FACILITY PROGRAM This'is in response to your request of March 5,1997, to review and comment on the subject draft non common performance indicators. We believe they are appropriate in depth and provide an appropriate level of detail to sufficiently address their respective program areas and to fit into the larger IMPEP program guidance.
We recommend two enhancements:
1.
' Define " appropriate adjustments" to inspections in fuel cycle inspection program, Criteria 1.
The satisfactory rating and satisfactory with recommendations rating should allow for changes to IMC 2600.due to emphasis to respond to events and reduction based on Licensee-Performance Reviews.
2.
There are semi quantitative descriptive words which appear throughout the document. These words, such as, " frequently," " periodically,"
"Mequately," " prompt," etc. could become a basis for misunderstandings.
To avo~id such misunderstandings, we suggest that an attempt be made to provide definitions or bounds for them.
If you have any questions, contact Ed McAlpine at (404) 562 4711.