ML20149J990

From kanterella
Jump to navigation Jump to search
Concurs W/Util 871229 Interpretation of Tech Spec 6.9.1.1 That Startup Repts Unneccessary When Only Small Number of Fuel Bundles of Different Design or Mfg Inserted in Reload Core for Test Purposes
ML20149J990
Person / Time
Site: Hatch  Southern Nuclear icon.png
Issue date: 01/25/1988
From: Crocker L
Office of Nuclear Reactor Regulation
To: Gucwa L
GEORGIA POWER CO.
References
NUDOCS 8802230313
Download: ML20149J990 (2)


Text

.

e January 25, 1988 e

Docket Nos.: 50-321 50-366 Mr. L. T. Gucwa Manager, Nuclear Safety and Licensing Georgia Power Cortpany P. O. Box 4545 Atlanta, GA 30302

Dear Mr. Gucwa:

Your letter of December 29, 1987, provided your interpretation of the requirements of Technical Specification 6.9.1.1 (both units) as regards the suttnittal of start-up reports.

We agree th>tt such reports are not necessary when only a small number of fuel bundles (typically four or fewer) of a different design or that have been manufactured by a different vendor are inserted in a re-load core for test purposes.

Such a small number of test fuel bundles would be expected to have only a minimal impact on conv performance. We would, of course, expett to be notified of any unexcected effects on core perfonrance due to the presence of such test fuel asserrblies.

Sincerely, Lawrence P. Crocker, Project Manager Project Directorate II-3 Division of Reactor Projects I/II cc: See next page Cor ence:

I011-3 PC{Ig SRt 9 90!!-3 LCrgcke r M 66d Wodges Acting PD 1/*W88 1Q5/08

/ /88 1/ /F8 l

P

)

O!STRIBUTION:

Docket File NRC & Local PORs PDd Reading Divisior. Director AD/ Region Licensing Assistant Project Manager J. Sniezek l