,s

_'

f

j.94Ctry

UNITED STATES

h

A.

NUCLEAR REGULATORY COMMISSION

.I

$

REoioN IV

i

%,..,

[. -

C11 RYAN PLAZA drive, SulTE 400

.

ARLlNGToN, TEXAS 76011-8064

..* .

July 22,J1997

..

Charles M. Dugger, Vice President

Operatier'

Waterford 3-

Entergy.

arations, Inc.

- P.O. Box d .

'

Killona, Louisiana 70066

'

,

SUBJECT: NRC INSPECTION REPORT 50-382/97-11 AND NOTICE OF VIOLATION

Dear Mr. Dugger:

An NRC inspection was conducted May 18 through June 28,1997, at your Waterford

. Steam Electric Station, Unit

reactor facility. The enclosed report presents the scope and

.

results of that inspection.

During the 6-week period covered by this inspection period, your conduct of activities at

Waterford 3 was generally characterized by good performance of operations, maintenance,

,

.

However, a violation of NRC requirements was identified.

I

engineering and plant support.

.

"

The violation is of concern because it involved an incdequate tagout which contributed to a

spill of approximately 5000 gallons of radioactive water from the spent fuel pool, in

addition, we are concerned that the control room operators exercised poor judgment by not

promptly and adequately addressing the spent fuel pool high-level alarm.

The violation is cited in the enclosed Notice of Violation (Notice) and the circumstances

surrounding the violation are described in detailin'the enclosed report. Please note that

j

you are required to respond to this letter and should follow the instructions specified in the

-

enclosed Notice when preparing your response. The NRC will use your response, in part,

to determine whether further enforcement action is necessary to ensure compliance with

regulatoiy requirements,

in accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter,

its enclosure (s), and your response (if you choose to provide one) will be placed in the NRC

Public Document Room (PDR). To the extent possible, your response should not include

any personal privacy, proprietary, or safeguards information so that it can be placed in the

- PDR without' redaction.

,

f

i

khh

,x

M

9707290140 970722

-

,

'

PDR

ADOCK 05000302

.

G

PDR

g

4

.o

Entergy Operations, Inc.

-2-

Should.you have any questions concerning this inspection, we will be pleased to discuss

them with you.

Sincerely.

.

t.bkg

-

Thomas P. Gwynn, Director

Division of Reactor Projects

Docket No.: 50-382

License No.: NPF-38

Enclosures:

1. Notice of Violation

,

2. NRC Inspection Report

50-382/97-11

1

cc w/ enclosures:

1

Executive Vice President and

Chief Operating Officer

'

Entergy Operations, Inc.

P.O. Box 31995

Jackson, Mississippi 39286 1995

Vice President, Operations Support

Entergy Operations, Inc.

P.O. Box 31995

Jackson, Mississippi 39286 1995

,

Wise, Carter, Child & Caraway

P.O. Box 651

Jackson, Mississippi 39205

)

General Manager, Plant Operations

'

Waterford 3 SES

Entergy Operations. Inc.

P.O. Box B

Killona, Louisiana 70066

'

gj _

_

.

-s _

..g...

-

. _ . . . -

-

- - . . . -

-

-. _ .

...

. -

,

,

j

{

g..

-

'

'

4

,

v

-

, . . .

< c

ny

.,

i

5

m.s

j

s.

ten ergy Opera'tionsillnc.

E-3-'

'

~

.l Manager) Licensing Manar,ar :

'i

~m

' Waterford 3 SES/

--

.

,

Entergy Operations, Inc.

l

' '

P.O. Bcx B

.

.

'

Killona, Louisiana E70066 '

'

. -i

~

e

'

"p Chairman ?

. .

. Louisiana Public Service'Co'mmission

j

~

One American Place! Suite 1630

j

Baton Rou'ge, Louisiana '. 70825-1697

iDirector, Nuclear Safety &

i

.

< LRegulatory Affairs .

'Waterford 3 SES

Entergy Operations, Inc.

P.O. Box B --

'

1Killona, Louisiana 70066l

,

i

,

I William H. Spell, Administrator

1

' Louisiana Radiition Protection Division

'

P.O Box'821351

. _

..

.

Baton Rouge, Louisiana 70884-2135

l

.;

.

p Parish._ President

'

St. Charles' Parish

? P.O. Box 302-

Hahnville, Louisiana : 70057

i

Mr. William A. Cross

l

Bethesda Licensing Office'

.i

3 Metro Center

i

,

'

Suite 610-

Bethesda,= Maryland 20'814

"

Winston & Strawn '

1400 L Street, N.W -

'

I

f Washington, D.C.f 20005 3502

1

,

m

W

E

.

I

v

,

.,

. . . .

-'

"

o..

,

.

f

,-

7

,}

'

'

-

' '

,

,,

,

,

;

.

=

.

-

. . .

,

.

.

_-

_ _ .

_ . _ _ .- , __ .

..

__

&*-. wQ

t

>

'4'

, v

. Entergy Operations, Inc.

-4-

E Mail report to T. Boyce (THB)

E-Mail report to NRR Event Tracking System (IPAS)

. E-Mail report to Document Control Desk (DOCDESK)

.

1

. E-Mail report to Richard Correia (RPC)'

E-Mail report to Ronald Frahm, Jr. (RKF)

bec to DCD (IE01)

bec distrib, by RIV:

Regional Administrator

Resident inspector

DRP Director .

DRS-PSB

Branch Chief (DRP/D)

MIS System

Project Engineer (DRP/D)

RI V File

- Branch Chief (DRP/TSS)

Leah Tremper (OC/LFDCB, MS: TWFN 9E10)

'

-

.

DOCUMENT NA E: ' R:\\,,WAT\\WT711RP LAK

To recobre copy of

indicate in box: "y = opy without enpipsures

"E" = Copy with enclosures "N" = No copy

RIV:SRIAff

C:DRP/D

dD:DRP.

[, /

.

,

,

LAKellprg W 1/

PHHarrfillf - TPGwynn M

07/('#97)1 \\'

t(T

07/g'\\1@PV

07R97,31

/

}

OFFICIAL RECOFD COPY

l

%

)

~

,.I'

'

"

290028

L