ML20149J072

From kanterella
Jump to navigation Jump to search
Discusses Enforcement Conference Conducted on 871218 W/Util Re Insp Repts 50-313/87-29 & 50-368/87-29 on 870818-20. Meeting Summary Encl
ML20149J072
Person / Time
Site: Arkansas Nuclear  
Issue date: 02/18/1988
From: Callan L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Campbell G
ARKANSAS POWER & LIGHT CO.
References
EA-87-227, NUDOCS 8802220261
Download: ML20149J072 (4)


See also: IR 05000313/1987029

Text

FEB i 81988

.*

o

Docket No.

50-313

50-368

License No.

NPF-46

EA No.287-227

Arkansas Power &' Light Company

. ATTN: .Mr. Gene Campbell

Vice President ~, Nuclear

Operations

P.O. Box 551

Little Rock, Arkansas 72203

Gentlemen:

This refers to the Enforcement Conference conducted in the NRC Region IV

Office on December 18, 1987, with you and other members of your staff, and

Region IV and Office of Nuclear Reactor Regulation personnel.

This conference

was related to the findings of the NRC inspection conducted during the period

August 18-20, 1987, which were documented in our NRC Inspection

Report 50-313/87-29; 50-368/87-29, dated December 3, 1987.

The subjects discussed at this meeting are described in the enclosed Meeting

Sumary.

In accordance with Section 2.790 of the NRC's "Rules of Practice " Part 2,

Title 10, Code of Federal Regulations, a copy of this letter will be placed in

the NRC's Public Document Room.

Should you have any questions concerning this matter, we will be pleased to

discuss them with you.

Sincerely,

Original Signed By

A. B. Deach

L. J. Callan, Director

Division of Reactor Projects

Enclosure:

Meeting Summary

cc w/ encl:

(seenextpage)

P4' h5

D:DRh

JLMt

an/cjg

LJCa"1 n

t/t /

2/l1/88

-TEoI

8802220261 080218

I

l

ADOCK 0 % g 3

DR

.

.. .

.

\\

,' f f '. . g

Arkansas Power & Light Company

-2-

g.

cc:

-Arkansas Nuclear One

ATTN:

J. M. Levine, Director.

.

Site Nuclear Operations

P.O. Box 608

Russellville, Arkansas 72801

Arkansas Radiation Control Program Director

bec to DMB (IE01)

bec distrib. by RIV:

RRI

R. D. Martin, RA

RPSB-DRSS

Section Chief (DRP/A)

Lisa Shea, RM/ALF

RIV File

DRP

MIS System.

RSTS Operator

Project Engineer, DRP/A

G. Dick, NRR Project Manager

R. Hall

DRS

TSS

D. Powers

- - -

'

..

--

._

_ _ _ _ _ _ _ _ _

t

cA

s

ATTACHMENT

ARKANSAS POWER & LIGHT COMPANY

DECEMBER 18, 1987

MEETING SUMMARY

Licensee:

Arkansas Power & Light Company (AP&L)

Facility:

Arkansas Nuclear One, Units 1 and 2 (AN0)

License No.:

NPF-46

Docket No.:

50-313

50-368

SUBJECT:

ENFORCEMENT CONFERENCE CONCERNING NRC INSPECTION FINDINGS

(INSPECTION REPORT 50-313/87-29; 50-368/87-29)

On December 18, 1987, representatives of Arkansas Power & Light Company, met in

Arlington, Texas, with NRC Region IV and NRR personnel to discuss the findings

documented in the NRC Inspection Report dated December 3, 1987. The attendance

list and licensee presentation are attached. The meeting was held at the

request of NRC, Region IV.

The NRC discussed its concerns regarding abnormal containment temperature

conditions in Unit I which resulted in (a) failure to inform the NRC, (b) failure

to evaluate the effects of high containment temperatures, and (c) reactor

operation with unqualified electrical equipment.

The licensee discussed the

cause for this condition, how the problem was discovered, the safety

significance of the matter and generalized corrective actions taken by the

licensee.

The licensee took the position there was no failure to report or

failure to evaluate.

Enclosures:

1.

Attendance List

2.

AP&L Presentation

- - . -

-.

-

_ _ - - - - - ,

e

, . . , ,,

' . .

ENCLOSURE 1

ENFORCEMENT CONFERENCE ATTENDANCE LIST - REGION IV

ARKANSAS POWER & LIGHT COMPANY

NRC Attendees:

J. Callan, Director, Division of Reactor Projects

A. Beach, Deputy Director, Division of Reactor Projects

J. Milhoan, Director, Division of Reactor Safety

D. Hunter, Chief Technical Support Section

W. Seidle, Chief, Operational Programs Section

W. Johnson, Senior Resident Inspector

G. Dick, Project Manager, NRR

H. Scott, Enforcement Staff

J. Gagliardo, Chief, Operations Branch

R. Hall,. Deputy Director, Division of Radiation Safety

and Safeguards

J. Tapia, Project Engineer, Division of Reactor Projects

Licensee Attendees:

T. G. Campbell, Vice President Nuclear

D. Howard, Manager Licensing

L. W. Humphrey, General Manager, Nuclear Quality

C. H. Turk, Superintendent Nuclear Engineering

R. W. Howerton, Manager Design Service

R. Lane, Manager Engineering

J. Levine, Executive Director

D. E. James, Licensing Supervisor

,