ML20149G018
| ML20149G018 | |
| Person / Time | |
|---|---|
| Site: | Comanche Peak |
| Issue date: | 02/12/1988 |
| From: | Counsil W TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC) |
| To: | NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM) |
| References | |
| TXX-88222, NUDOCS 8802180069 | |
| Download: ML20149G018 (1) | |
Text
MF-Log # TXX-38222 File # 10130 IR 86-03 IR 86-02 N# ELECTRIC Ref. # 10CFR2.201
$$i7,Sd%,1, February 12, 1988 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C.
20555
SUBJECT:
COMANCilE PEAK STEAM ELECTRIC STATION (CPSES)
DOCKET N05. 50-445 AND 50-446 INSPECTION REPORT 50-445/86-03 AND 50-446/86-02 BASE METAL DEFECT REF:
(1) TV Electric Letter TXX-6964 from W. G. Counsil to l
NRC dated November 20, 1987 (2) TV Electric Letter TXX-7131 from W. G. Counsil to NRC dated December 31, 1987 Gentlemen:
The letter identified in reference 1 provided supplemental information concerning base material defects. The letter identified in reference 2 provided information relative to the Field Verification Method (CPE-CPE-FVM ME-114) used to validate (for base material defects due to grinding) welds from a representative sample of 60 pipe supports.
This work activity has been completed, and based on the inspection criteria delineated in the FVM, no adverse findings related to base material defects due to grinding were observed. A full report summarizing the inspection results is available on site for your review.
Very truly yours, 674 W. G. Counsil BSO/grr c - Mr. R. D. Martin, Region IV Resident inspectors, CPSES (3) pO'f 8802180069 800212 i
()
gDR ADOCK 05000445 PCR 400 North Olm Street LB81 Dallas. Texas H.*01
.