STATE OF CONNECTICUT ** DEI, RTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Discharge Monitodng Report (DMR)
DATE RECEIVED (STAMPED)
I Permit: CT000326 MAJ Dist: 12 Town:152 Loc:003 Facility:
- MILLSTONE NUCLEAR POWER STA.
Contact:
Paul Brindamour i
Town: WATERFORD Phone:(203) 665-3174 Logged Delivered:
OK'd:
KEY: CT0003263 issue: 121492 Expire: 12/14/97 Sample Month September 1995 Average Flow: 2738000000 GPD ND = none detected Discharg 001 1 Mon Loc 1 COOLING WATER < 5000 Sample Weeks:
Code Start s/m Typ Unit Parameter Minimo Average aximu Freq 1
2 3
4 5
r 50064 121492
.. Of t G
MG/L CHLORINE FREE AVAILA ND 0.02 01/07 <0.02 0.02 <0.02 0.02 50060 121492 0/1 G
MG/L CHt_ORINE TOTAL RESID ND 0.02 01/07 <0.02 0.02 <0.02 0.02 50050 121492 Off I
MGD FLOW,IN CONDUlT OR THRU 2830 24/01 SEE ATTACHED TABLE 00400 121492 0/1 G
SU PH 7.5 7.9 24/01 SEE ATTACHED TABLE 00018 121492 0/1 I DEG TEMP DIFF BETWEEN SAMP 17.2 21.4 22.9 02/14 SEE ATTACHED TABLE i
00011 121492 Off I DEG TEMP. DEG FAHRENHEIT 87.1 90.6 93.4 24/01 SEE ATTACHED TABLE 00015 121492 0/1 CA BTU / THERMAL DISCHARGE MILLION 20951.5 22501.6 01/01 SEE ATTACHED TABLE e
KEY: C10003263 issue: 121492 Expire: 12/14/97 Sample Month September 1995 Average Flow 2738000000 GPD ND = pone detected e"
Discharg 0011 Mon Loc 7 COOLING WATER < 5000 Sample Weeks:
Code Start s/m Typ Unit Parameter Minimu Average aximo Freq 1
2 3
4 5
l
,e 2
00011 121492 0/1 1
DEG TEMPERATURE DEG FAHR 93.6 24/01~
SEE ATTACHED TABLE See note 1 i
w COMMENTS:
Note 1 = High intake temperature due to plant backwash procedure to control biofouling.
t f
i Page 1
[
9707220285 970702 PDR ADOCK 05000245 R
i s -
1 j
ETATE OF CONNECTICUT ** DEPARTMENT OF ENVIRONMENTAL PROTECTION l
Bureau af WIter Management - Dischargs Monitoring Report (DMR]
i KEY: CT0003263 Issue: 121492 Expire: 12/14197 Sample Month Scotember 1995 ND = none detected Average Flow: 604800000 GPD Discharge 01 A 1 Mon Loc: 1 COOLING WATER < 5000 Sample Weeks:
i Mwwnum Average Maximum Frea 1
2 3
4 5
i Code Start s/m Typ Unit Parameter 02/99 NO DISCHARGE 00164 120192 011 T
GPS FLOW, GALLONS / BATCH i
01/07 NO DISCHARGE 00400 091686 OJO G
SU PH 00095 091686 DJO G
HM/C SPECIFIC CONDUCTANCE 01/07 NO DISCHARGE i
l Comments:
KEY: CT0003263 Issue: 121492 Expire: 12/14/97 Sample Month Sectember 1995 ND = none detected Average Flow: 14000 GPD t'
Discharge 01 A2 Mon Loc: 1 BUILDING FLOOR DRAIN Sample Weeks:
Code Start s/m Typ Unit Parameter Meimum Average Maximum Free 1
2 3
4 5
?
9904 01/01 9572 9904 9788 9572 j
n0164 120192 0/1 T
GPS FLOW, GALLONS / BATCH
.(/1 7.I,7 741 7 O'7
..u.
01J0'r 7,46 7,i26 7.10 7:00 00400 091986 OJO G
SU PH
?
c.osg
.Ot1
,et 1.
.06]
OctSO 01/07.6072.9990.0074.0038 00530 120192 0/1
- G KGJD SOLIDS, TOTAL SUSPENDED o.5 0.5 02-r i
9:4 01J07 0.2 0.4 0.2
-6:1 00530 120192 0/1 G
MGJL SOLIDS,TOTALSUSPENDED i
j e KEY:CT0003263 Issue: 121492 Expire: 12/14/97 Samp e Month September 1995 8
ND = none detected Average Flow: 3500 GFD e* Discharge 01 A 4 Mon Loc: 1 WATER PRODUCTION WASTEWTR 4
Sample Weeks:
Code Start sam Typ Unit Parameter Minimum Average Marimum Frea 1
2 3
4 5
i Code 9 WH/DS e
e 00698 120192 0/1 G
KGJD BORIC ACID j
d a
Code 9 WH/DS "co. 00698 120192 011 G
MGJL BORIC ACID s
01JBA No discharge -
I 00164 120192 011 T
GPB FLOW. GALLONS / BATCH Page 11 2
_.,_..,,,,..,,m.,
m.._,.
1 Sept 1995 l
DSN001A-2 Additional Data September 199S Total Suspended Tank Volume Solids TSS Volume Discharged DATE pH (TSS)
(kg/ batch) (gallons)
(gallons) i l
l 09/03/95 7.29 0.5 0.018 10,595 9,559 l
l 09/05/95 7.24 0.2 0.007 10,484 9,458 i
l 09/06/95 7.67 0.1 0.003 10,150 9,098 09/08/95 7.10 0.2 0.007 10,600 9,572 09/10/95 7.20 0.2 0.007 10,825 9,904 l
09/12/95 7.22 0.2 0.006 8,900 8,205 09/13/95 7.38 0.2 0.007 9,700 8,647 09/15/95 7.29 0.0 0.000 10,850 9,789 09/15/95 7.07 0.4 0.012 8,850 8,088 09/18/95 7.00 0.1 0.004 10,250 9,344 09/19/95 7.10 0.2 0.007 10,750 9,788 09/20/95 7.00 0.1 0.003 10,250 9,116 09/22/95 6.90 0.2 0.007 10,400 9,212 l
09/23/95 7.00 0.1 0.003 10,250 9,116
)
09/25/95 7.00 0.1 0.004 10,750 9,572 09/27/95 7.04 0.1 0.003 9,400 8,176 09/28/95 7.07 0.0 0.000 10,500 9,572 09/29/95 6.86 0.2 0.007 10,500 9,328 09/30/95 7.06 0.1 0.003 9,750 8,637 1
I i
l l
l Page 42 l
i
~-
0
_~-~ - - - -, - - - - - - - - - - _ _ _ _ _ _, _. _ _ _, _ _ _ _ _ _. _ _.
STATE OF C0001ECTIctN ** DEPARTMENT OF ENWWt000AENTALPROTECT8004 Sween of Weser Menseenient - Discaiwee Menleedne Report SMR$
o ao m
3 Sesupu Monet, poseender 1935 vi ICEY: CT0003243 issuet 121492 Esgstre: 1211427 DB = siene detected Aversee How: 1400000 GPO l
l Diestierge OlC 9 Menime: 1 STEAM ELECTft0C POWER PLNT Sasuple Weeks:
t Minineani Averene Menimune N 1
2 3
4 5_
j Code Start shui Tve LBnet Parenister
~
l Code 9 0259 ConditionalMonisedne 00000 089998 em G
IGD DORIC ACB O Elf 0 24y l
o *K j
Omi Oim m - ~ - -
i
.0090 i20i.2 wi i
Mao nOW. CONouironm.
s.c s.y
,.s-a I
943 0147 3.6 0.C
.": 0.03 cp 80400 091988 em G
EU PH o
i O
<0At 0127 <041 <0Al <0A1 <0Al 00630 120192 Oft G
MGA. SOUDS. TOTAL SUSPENDED ND 212 01JD7 202 212 212 212 l
00011 120192 Oft G
DEG F TEMPERATultE DEG FAHR Y.vv 4M My h6/l 674
,~
i Sesople M ench
$estember 1995 IS = siene detected f
K!!!Y C10003283 leeue:129492 Empire:12tt4t97 Aversee Flow: 25000 GFD Diestiesgo 01C 2 Men tas:1 mm nacG FLOOR ORAIN Sengen Weeks:
Minknuni Aversee Moulniune Fsee 1
2 3
4 5 _
i l
' Code Start ans Tye Lendt Peremeter N.)
70.4-494 57.1 39'D t
70.4 0147 70A 48A 57.5 39A l
90098 120192 0 71 Isc ItGJD 00RIC ACD iM3o sw 170st> tt,3%b 8654C 83% D 17010* 012714690 HUte 1839014910 a
l 00144 120992 Off I
Gr0 ROW. GALLONSmATCH Zs.\\
o.3:1 0.27 01J07 40.1 027 <0:1 0:20-0.LO MGA. LITHIUM. TOTAL (AS LE Mp
\\
08132 001988 OdO G
9.19 14% 9.41 T.% 1 53 est Oim 7A1 sm es3
- ss e.9 0040R 09 See Om G
su en
+15 5I i 2.5.D +4.0 4-%.o 445 0147 57:9 4to 445 333
$3%b
]
00095 091988 em G
SOAJC SPECIFICCONDUCTANCE COMMENTS:
4 1
Paae 18 4
1 i
,,%-_r...,--.w-%,.we,-
,.9--.n,w-..,p, g.,.,ry,e,gwgy,yw....,,,g,,.,%,,,.qwyw,,,,,w..,.wm,,_,--
,ywyge,.p-yw-,,-w,
,,,g,,,ym.-4
.,._,,,s.y.,g.,..,,g,y.,-
,.iewg-,,wt-e,v-w*P-.-e~~*-w.,
r--
i l
DSN 001C-2 Additional Data September 1995 l
Specific l
I Conductivity l VOLUME Boric Acid l Lithium (ppm)
Source l
t Date i
pH (gallons) I (kg) 09/01/95 8.48 151.00 17430 18.10 WTT-B 09/03/95 8.38 121.00 16800 23.00
<.1 W-A 09/06/95 7.41 57.00 16590 70.40
<.1 W-B l
09/09/95 8.41 125.00 18060 36.20 W -A 09/14/95 8.99 44.00 17010 48.40 0.27 WB l
09/17/95 8.83 475.00 16380 57.80 W-A 09/20/95 9.19 426.00 9600 27.90 WTT-A 09/26/95 8.98 339.00 14910 39.00 0.20 WTT-A 09/26/95 8.87 198.00 15540 17.70 WTT-A 09/29/95 8.78 129.00 15330 34.50
<.1 WTT-B l
l l
STATE OF CONNECTICUT ** OEPARTMENT OF ENVIRONMENT 1 4_..: - Discherse MenMorias Report (DMI4 Bureens of Water -
Sample Month M,.tr1995 NO = none detected Empire: 12114/97 teste: 121492 REY:CTUOO3263 Average Flew: 5000 GPD St.OWDOVWN FR HEAT & COOT.
Sample Weeks:
MenLoc:1 1
2 3
4 5
Descharge 01C 3 Minimum Average Menimum Frog Code Start man Typ Unit Parameter 0.%
0.1 3w 53.0 23 7 43.9 VWH/DS 434. 29 3 SfA M
RGJO 90RIC ACID 3YbD 32o0 Suo 34so 344o 3490 8320 0127 3290 3240 3320 3240 00098 120192 Off G
t.Ao tw1 s248 1a At GPS FLOW, gat 10NSSATCH t2A 014 7 12:44 11:32 12-44 90:38 l1 M 00164 120192 Off T
00400 091998 Of0 0
50 PH nn.o so.% n o.ta 85 3 15.7 0127 10-9 10:S 13:8 45:7 15.7 MGA. SOUDS. TOTAL.StiwsNDED 00530 120192 Oft G
Sernate M onth C._:_.ir 1995 ND = none detected REY:Cf0003283 genue: 129492 Espire: 12tf 437 Average Flow: 80000 GPD WATER PRODUCTION WASTEWTR sermyneweeks:
Men toe: 1 1
2 3
4 5_
Olscheese OfC 4 Minimurn Average Montemen T.w Code Start eAn Typ IMIt Persmeter 52000 51000
- 0127 54000 52333 CPS FLOW,GALLONSSATDf 1.0
<0.2 00194 091996 04 7
1.0 02S9 <0.2 ND 81313 091996 04 G
MGA. MVDRAZINE 7.0 7.0 7.3 0127 7.3 00400 091998 00 0
SU PH 1.7 18.7 18.7 0127 0.8 MGA. SOLIOS,TOTAt.StrarusDED 00530 120192 Off G
Sample Month M:..tr 1995 NO = nonedetected Besue: 121492 Expos: 12/14/97
-KEY:CT0003263 Average Flow: 43200000 GPO Sere,se weeks:
NON-CONTACT COOUNG WATER 1
2 3
4 5_
Mon Lee: 1 Otacharge OfC S Aveenge Menimurn Free
.046 0f47 Ort 8 SAS 4:93 OA2 Minimum
- olt, 0.17 0.* T o.ti o.lf
- Unft Parameter Code Start eAn Typ MGA, CHl.ORINE, FREE AVAlt.ABt.E c.t y 43.2 02S9 43.2 43.2 43.2 43.2
_ 50064 120192 Ott G
MGD FLOW,1N CONOUtT OR THRU es 01m7 89 se es s7 50050 120192 Oft i
000ss
$20s92 Ofs Geor p oEurAnR M es kken. tdrakIf A4.m A I
$ hJor/n.s-F\\ege 11 A All:4.%J i
DSN 001C-3 Additionri D:ta September 1995 4
i Total Suspended VOLUME Boric Acid Source l Solids (ppm)
Date pH (gallons)
(kg) 09/01/95 11.40 11.00 3200 0.69 LLWDT-B j
3 b 09/02/95 11.10 3.2 3120 0.99 LLWDT-A 09/03/95 11.27 1.10 3280 0.47 LLWDT-B 09/03/95 11.26 0.6 3360 0.38 LLWDT-A 39/04/95 11.16 0.90 3240 2.51 LLWDT-B 09/05/95 12.45 9.3 3320 29.40 LLWDT-A 09/06/95 11.42 1.00 3120 0.31 LLWDT-B 09/06/95 12.44 10.8 3280 43.90 LLWDT-A
@ 09/07/95 11.47 0.80 3240 2.03 LLWDT B 09/07/95 12.47 7.4 3440 18.50 LLWDT-A 09/08/95 11.53.
0.90 3280 0.71 LLWDT-B 09/08/95 12.45 9.1 3240 17.40 LLWDT-A 09/09/95 12.40 6.8 3400 30.90 LLWDT-A
~09/10/95 11.30 2.50 3240 2.63 LLWDT-B 09/11/95 11.60 1.7 3200 16.80 LLWDT-A 09/11/95 12.50 9.6 3200 23.80 LLWDT-A 09/12/95 11.17 1.80 3160 2.45 LLWDT-B 09/12/95 12.49 10.6 3320 27.30 LLWDT-A 09/13/95 11.97 2.00 3480 4.97 LLWDT-B 09/13/95 12.32 10.3 3240 25.30 LLWDT-A 09/14/95 12.39 4.2 3280 24.20 LLWDT-A 09/15/95 11.70 1.50 2800 2.71 LLWDT-B 09/15/95 12.00 6.7 3200 39.00 LLWDT A 09/16/95 11.50 2.10 3440 3.61 LLWDT-B
~
09/17/95 11.40 1.2 3240 2.73 LLWDT-A 09/18/95 12.48 15.30 3240 16.50 LLWDT-B 09/18/95 12.47 5.8 3200 24.50 LLWDT-A 09/19/95 11.39 1.20 3240 0.85 LLWDT-B 09/19/95 12.45 5.7 3200 26.10 LLWDT-A 09/20/95 12.42 4.4 3200 33.00 LLWDT-A 09/21/95 11.30 3.10 3280 0.88 LLWDT-B 09/21/95 12.4 4 4.8 3240 23.00 LLWDT A 09/22/95 12.44 13.80 3320 31.00 LLWDT-B 09/23/95 12.39 9.30 3440 16.00 LLWDT-B
~
09/23/95 12.21 3.5 3440 8.10 LLWDT-A 09/24/95 11.82 2.70 3240 5.50 LLWDT-B 09/25/95 9.68 3.50 3240 5.50 LLWDT-B 09/25/95 9.70 8.3 3480 9.30 LLWDT-A
,g 09/26/95 9.59 3.1 3240 LLWDT-A G
09/27/95 10.38 15.7 3240 7.40 LLWDT-A 09/28/95 11.06 7.30 3320 23.90 LLWDT-B 09/29/95 11.30 1.4 3240 1.99 LLWDT-A 09/30/95 11.36 1.30 3360 1.96 LLWDT-B
PERMIT: CT0003263 DIST: 12 TOWN: 152 LOC: 003 FACILITY:
MILLSTONE NUCLEAR POWER STA.
MAILING NAME-NORTHEAST NUCLEAR ENERGY CO.
ADDRESS:
RTE 156 ADDRESS:
P.O. BOX 270 CITY, STATE, ZIP:
WATERFORD, CT 06385 CITY, STATE, ZIP; HARTFORD, CT 06101 CONTACT:
MR. PAUL JACOBSON CONTACT:
MR. PAUL JACOBSON PHONE:
(860)447-1791 (x2335)
PHONE:
(860) 447-1791 (x2335)
If there are any changes or corrections with your facility information, please cross out incorrect information and replace with correct information.
THIS REVISED DMR CONSISTS OF PAGES FOR THE REPORTING PERIOD STATEMENT OF ACKNOWLEDGMENT v.a t and all DMR revisions attached hereto, which only I certify under penalty of law that this revised w constitute revisions as specifically noted to pages and attachments previously submitted, were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the revised information submitted is, to the best of my knowledge and belief, true, accurate and complete.
I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.
Authorized Official:
S.
E.
Scace
Title:
Director. Nuclear Enoineerino Procrams, NNECO l
s
/ d (f Date: :
I Signature:
j, m
-