DUKE POWER COMPANY P.O. BOX 33180 CHAMLOTTP, N.C. 28242 HAI. B. TUCKER retmenoMn m reussen (yo4) aya-4 sag January 12, 1988 Dr. J. Nelson Grace Regional Administrator U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW Suite 2900 Atlanta, Georgia 30323
Subject:
Duke Power Company Oconee Nuclear Station Docket Nos. 50-269, - 270, - 287 McGuire Nuclear Station Docket Nos. 50-369, -370 Catawba Nuclear Station Docket Nos. 50-413, -414 Response to NRC Compliance Bulletin No. 87-02 Attached is a partial Duke Power response to NRC Compliance Bulletin No. 87-02, "Fastener Testing to Determine Conformance with Applicable Material Specifications."
Included as attachments to this letter is the following information required by the bulletin.
Attachment A Description of the Duke Power Procurement and Receipt Inspection Program for Fasteners Attachment B Description of the Duke Power Controls Used During Storage and Issuance From Stock to Assure the Appropriate Use of Fasteners Attachment C Method for choosing the Fasteners to be Tested Attachment D Status and Schedule of the Evaluation of Fastener Testing Results I
l/
s
'8801140236 880112 PDR ADOCK 05000269 0
.DCD
^
Dr. J. Nelson Grace Page #2 January 12, 1988 At this time, we are unable to submit the test results and the evaluation thereof.
This is because 1) we were unable to complete the overall workload required by this bulletin within the 60-day time allotment; 2) the time required to interface with vendor testing laboratories; and 3) the performance of Charpy Impact Testing on some samples.
This latter item, although not specifically required by Compliance Bulletin 87-02, was requested by the NRC Resident Inspectors based upon interpretation of the NRC Temporary Instruction 2500/26 covering the bulletin.
Presently we have completed the mechanical and chemical testing of all samples (except the additional impact testing of the required samples).
The status and schedule of the evaluation of the test reaults is detailed in Attacament D.
I declare under penalty of perjury that the statements set forth herein are true and correct to the best of my knowledge.
Very truly yours, b/kr Hal B. Tucker HBT/JSW/lec Original Letter and Copy of Attachments:
U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C.
20555 xc:
(w/ Attachments):
NRC Resident Inspector Oconee Nuclear Station NRC Resident Inspector McGuire Nuclear Station NRC Resident Inspection Catawba Nuclear Station 1
1
_.. -. _ _., ~. _ _... _ _ _ _ _., _ _
Attachment A Duke Powr r Company Response to NRC Compliance Bulletin 8 7-02 "Description of the Duke Power Procurement I
and Receipt Inspection Program for Fasteners" l
j INTRODUCTION The Quality Assurance Procurement Program is based on the following:
I a) Review of requisitions and purchase orders by QA personnel b) QA Vendor audits and surveillances of suppliers c) Duke QA releases required prior to shipment d) Review of vendor documentation by QA Vendors e) Receiving inspection by site QA QA REVIEW OF REQUISITIONS AND PURCHASE ORDERS All QA Condition purchase orders and requisitions are reviewed by l
Quality Assurance personnel to assure the appropriate documentation requirements are specified on the purchase orders.
QA VENDOR AUDITS AND SURVEILLANCES During audit / surveillance activities, Duke representatives verify that the vendor has applied applicable sections of their approved quality program to the materials being purchased. examples of audit and surveillance activities are a) Reviewing Certified Material Test Reports (CMTR's);
comparison to ASME Code Section II requirements as applicable.
b) Reviewing heat treat records.
c) Performing dimensional verification.
d) Reviewing audit reports, inspection reports, Nondestructive Examination (NDE) reports, equipment calibration records, and employee qualifications and certification records, ei verifying proper markings.
f) Reviewing the vendor's purchase documents.
g) Verifying that stock materials used were from approved source or (when applicable) properly qualified (eg., NCA-3 86 7. 4 e).
h) Verifying acceptance of physical properties such as hardness, tensile, yield, and impact through document review, i) Witnessing manufacturing and testing processes.
4 Attachment A Response To NRC Compliance Bulletin 87-02 Page 2 QA RELEASE BY QA VENDORS In addition to subject audits and surveillances, the vendor is required by each safety related purchase order to receive a Duke QA release prior to shipment, except as exempted per procedure.
When notified by the vendor that an item is ready for shipment, QA Vendors schedules a visit to the vendor or grants a telephone release. We perform surveillances for approximately 10% of the purchase orders. For the other 90%, QA Vendors perform telephone communications to obtain the suf ficient information to grant releases. The QA Vendors Division documents their release on Form QA-605, "QA Vendors Release". Verification of proper marking, proper documentation, and material manufacturer would be addressed as a minimum.
QA REVIEW OF VENDOR DOCUMENTATION Vendor documentation is forwarded to Duke's QA Vendor Division Documentation Section for review. If found acceptable, documentation is approved and forwarded to applicable etations (approval is required and forwarded to applicable stations use).
The applicable site is notified if problems are noted and material is placed in "HOLD" statues pending satisfactory resolution.
During the review, the following areas are verified:
a) Comparisons to purchase order.
b) Chemical and physical properties reported are compared with applicable material specifications.
c) Assure applicable ASME Code requirements have been included in the certification.
d) Necessary historical and added testing data are included in the documentation package for material qualified per i
NCA-3 86 7. 4 (e).
e) Verify that the material supplier is an approved vendor, QA RECEIVING INSPECTION The receiving inspections at Duke's Nuclear sites are performed to ensure conformance of material to the purchase order. The QA procedure used for receipt at the site requires the material to be visually examined to assure identification and markings are in accordance with the purchase orders, standards and the vendor
)
documentation.
4
Attachm2nt A f
Response To NRC Compliance Bulletin 87-02 Page 3 QA RECEIVING INSPECTION CONTINUED:
All QA condition materials are identified with an unique OA Tag Number in addition to the assigned company number (i.e., MMIS Number). The QA Tag Number is specified to a given purchase order and a single line on that purchase order. This tag is either attached to the item)s.itself or on the packages (s) or container (s). Some items transferred from a Construction Program may not be traceable to purchase orders. In those cases sufficient documentation shall be specified to establish the acceptability of the item.
1 I
)
d
-Attachment B Duke power Company Response to NRC Compliance Bulletin 87-02 "Description of the Duke Power Controls Used During Storage and Issuance From Stock to Assure the Appropriate Use of Fastener" L
All fasteners are stored in accordance with the requirements of ANSI N45.2.2 Level B or C.
procedures in each station's materials manual describe the controls applied for the handling and storage of items (not just fasteners).
Stock fasteners are assigned a company number which facilitates in the retrieval of procurement information in addition to being used in the control of inventories and other company business needs.
Non-stock fasteners are not identified by a company number since, in most situations, they are fasteners that are not cornen to other uses or applications.
Fasteners are identified for use normally in one of two ways.
First, the Duke Design Engineering Department's piping installation specification (covering flange connections, etc.), hanger installation specification, and various electrical installation specifications are all used in identifying a need for fasteners.
The second and most often used method is through each equipment specification and associated instruction manuals, maintenance manuals, and equipment drawings which have bills of material. The majority of fasteners in this category would be identified by a manufacturer's part number or by some relationship to the equipment. Much of the information from these documents can be found on data bases. After selection for procurement through one of the methods above, the fastener would be stored and identified as described previously.
In addition to the assigned company number, all stock and non-stock QA fasteners are assigned a unique QA tag number. This number is unique to a specific line item on a specific purchase order.
For safety-related fasteners, the QA tag number facilitates traceability to the installed location required by 10 CFR 50 Appendix B.
The issuance of QA fasteners is controlled by procedures found in each station's materials manual. These fasteners are issued to a work request, which is the Duke administrative program used to control maintenance work activities at each station, that identifies and captures all pertinent data such as company and QA tag number, quantities, procedures utilized, and other descriptive information. Although non-QA fasteners are not required to be issued to a work request, in many cases they will be included since the equipment they are used or. is safety-related. Their actual function in those cases, however is not considered safety-related.
If fasteners have not been adequately identified l
on design documents or data bases and there is a question concerning the proper fastener, it is the responsibility of the site engineering section to provide (with the help of Design Engineering if needed) the maintenance technician with the correct fastener for that particular application.
i j
Attachment C Duke Power Company Response to NRC Bulletin 87-02 Method for Choosina the Fasteners to be Tested.
The selection process began by listing all: 1. Bolts 2. Scraws 3. Studs 4.
Capscrews and 5. Nuts described in the KMIS (Materials Management Information System) computer data files for each station.
l The following factors were used in the selection of test samples.
1.
Fasteners listed as standard issue fasteners, not necessarily listed as a part for a specific component, were chosen.
In a few cases (especially Oconee), there was not a suitably large selection of general issue fasteners and so the list was supplemented by equipment vendor supplied fasteners.
2.
Fasteners that represented an assortment of different materials were chosen.
For a reasonable number of fasteners, the description listed the material type.
3.
Fasteners that represented an assortment of manufacturers and suppliers were chosen. The MMIS list had very little information on manufacturers and suppliers but the samples chosen took this requirement into account as much as possible.
4.
If tensile tests were required (such as safety related bolts), fasteners had to be at least 4 inches long and, if possible, with either 3/8-16 or 3/4-10 threads to accommodate tensile specimen fabrication. To support chemical analysis, the fasteners were at least 3/8 inch nominal size.
In some cases, samples were slightly smaller than this. To assure their representation, some safety related fasteners shorter than 4 inches were added to the Non-Safety list.
(Testing under bulletin 87-02 is identical for QA and non-QA bolts except for tensile testing.)
A list of forty fasteners was made for each station and presented to each station's NRC resident inspector as a draft from which to begin. The MMIS numbers that begin with "1007", the Construction Department numbering method, are coded for the piping class they are to be used or..
For safety related fasteners the last alpha character is either A, B, or C.
The eight or nine digit numbers, Nuclear Production Department numbering method, are safety related if they end with an "N".
Non safety related fastener lists contain a number of safety related fasteners because of the reason stated in paragraph 4.
above and because general purpose fasteners are often purchased as safety related to allow a greater versatility of application.
Some minor discrepancies were found in the nomenclature of MMIS descriptions. A final i
list of fasteners from each station is attached.
McGuire Fastener Sampling On November 25, 1987 Bill orders, NRC Resident Inspector for McGuire, reviewed the list of fasteners and performed an inspection of the fasteners in stock.
I i
Attachment C,
The NRC Temporary Instructions concerning this bulletin recommended fasteners be added if they had one of nine manufacturer codes or no code.
Four examples of this were found and two of them were exchanged with others on the list.
Also found during the inspection was threaded rod which is often issued for making studs.
A sample of this was added also. Mr. Orders then reviewed the diversity of materials and manufacturers and agreed that the adjusted sample selection was acceptable.
Six samples were replaced on Decemb3r 2, 1987 because the samples originally chosen were out of stock or daleted from stock.
A letter was written to document this adjustment to the line. Other minor list adjustments were made after verbal confirmation with Bill Orders.
For HMIS sequence number 0253580, Sample Numbers MNS/NQ/SCRW/15 and 16, two different manufacturers were found so both were used.
Catawba Fastener Sampling On November 30, 1987 Mark Lesser, NRC Resident Inspector for Catawba, reviewed the list of fasteners, tabulated them by material type, and performed an inspection of the fasteners in stock. Threaded rod was found but not chosen because a storekeeper familiar with fasteners atated that it was not issued very often; also the material types and manufacturers were represented by other bolt samples.
Two non-QA bolt samples were chosen and one of them was added to the list.
Mr. Lesser then reviewed the diversity of materials and manufacturers and agreed that the adjusted sample selection was acceptable.
Four fasteners were replaced on December 3, 1987 because the samples originally chosen were out of stock or were misnumbered. A letter was written to document this adjustment to the list.
Oconee Fastener Sampling On December 1, 1987 Len Wert NRC Resident Inspector for Oconee and Nick Economos of Region II reviewed the list of fasteners, tabulated them by material type, and performed an inspection of the fasteners in stock.
Threaded rod was found and an example was added to the list.
Silica Bronze and eye bolt fasteners were removed from the list because they were not of interest to this bulletin. Oconee carries very few standard issue, general purpose fasteners and so most of the fasteners selected were Safety Related and associated with a specific plant purpose. Two materials and manufacturers of nuts were found under MMIS number 1007B3ANIC0B010 and so both were used (samples GNS/QA/ NUT /26 and 27). MMIS number 23210244N was received as a nut and bolt pair so the bolt is sample ONS/QA/ BOLT /5 and the nut is ONS/QA/ NUT /22.
Mr. Economos and Mr. Wert both reviewed the diversity of materials and manufacturers and agreed that the adjusted sample selection was acceptable.
Len Wert later notified us that MMIS number 1007B1ASICOG007050 was not a Safety Related fastener and it was exchanged for a QA fastener from the non-QA list.
Sample Testing Chemical analysis for all fastener samples was performed by Chicago Spectro Service Laboratory Inc. 4848 South Kedzie Ave. Chicago IL 60632.
This company i
is an app.oved vendor for providing analytical services under the Duke Power QA program. Hardness and tensile testing was performed in and under the QA program of the metallurgy laboratory of the Production Support Department of Duke Power Company.
It has been proposed that Law Engineering Servic e Charlotte NC perform the Charpy impact property tests.
Law Engineering alp has Duke QA approval for material testing.
Attachment C
' Oconee List of Fastener Samples (As of January 5, 1988)
Safety Related Bolts Sample Number MMIS Description MMIS Number ONS/QA/ BOLT /1 Bolt Mach Hex SS 3/4-10X3 1/2 SA-193/B8 02624012N ONS/QA/ BOLT /2 Bolt, Mach Hex HD SS 5/8-11X6 SA193/B8 02624017N ONS/QA/ BOLT /3 Bolt, Mach HVY KD CS 7/8-9 X 6-1/2 A325 02623399N ONS/QA/ ROD /4 Rod,THRD Alloy Steel 3/4-10 SA193 GR B7 1007B1ARICOB006 ONS/QA/ BOLT /5 Bolt, Hex Head RV 1-8X3 1/2 193 B7 23210244N ONS/QA/ STUD /6 Stud,CS 112T 1-8X7-1/4 OTSG PRI INSPECT 23240157N ONS/QA/ STUD /7 Stud, Load Pipe Clamp.750 X 10UNCX6.50 0298EE04FN ONS/QA/ STUD /8 Stud 1006688-001 MK#145 3/4" OTSG SEC 02691449N ONS/QA/ CAP /9 Capscrew, Hex HD 1-1/8-7X8 1/4 CD SA193 02653107N ONS/QA/ CAP /10 Capscrew, Soc HD 1-1/2-6X4 A574 LIMITOR 02655186N Non Safety Bolts ONS/NQ/ BOLT /11 Bolt Machine Hex HD CS 7/8-9 X 4 GR 8 02623157 ONS/NQ/ BOLT /12 Bolt Mach HVY Hex HD CS 1/2-13 X 2 A325 02621252N ONS/NQ/ BOLT /13 Bolt, Bracket 8348556 Diesel Generator 29020732N ONS/NQ/ STUD /14 Stud,B7 CL G 7/8-9 5 SA193 1007B1ASIC0G007050 ONS/NQ/ BOLT /15 Bolt, Hex HD 1 1/4 X 6 A325 RCP Motor 20110249 ONS/NQ/ BOLT /16 Bolt,Shell Mnwy Cvr 1-1/4-8 X 10 MSRH N205023453 ONS/NQ/ BOLT /17 Bolt,023 5/16 X 4 Fuel & Lube Oil Pmp 20391186N ONS/NQ/SCRW/18 Screw,Assy HH 1/2-13X2 306/307 10 KIP 0298Cv55FN ONS/NQ/SCRW/19 Screw, Cap Hex HD SS 3/8-16 X 2 B8M 02652100N ONS/NQ/ CAP /20 Capscrew, Soc HD 20 1X3-1/4 RCP Bingham 20110389N 1
Safety Related Nuts ONS/QA/ NUT /21 Nut, Hex AS 3/8-16 SA194 GR 8 CL B 1007CIAMICOB003 ONS/QA/ NUT /22 Nut, Hex 1-8 194 B7 CS (with bolt) 23210244N ONS/QA/ NUT /23 Nut, Hex CD 7/16-20 GRADE 8 02640007N ONS/QA/ NUT /24 Nut, Hex SS 3/8-16 A194 GRADE B8M 02642083N ONS/QA/ NUT /25 Nut,HVY Hex SS 3/4-10 SA194 GR 8 02642061N ONS/QA/ NUT /26 Nut. Hex 1-8 SA194 2H QA Tag 39323 Mfg"J" 1007B3ANICOB010 ONS/QA/ NUT /27 Nut, Hex 1-8 SA194 GR7 QA Tag 46009 Mfg"CU" 1007B3ANICOB010 ONS/QA/ NUT /28 Nut,HVY Hex CS 3/4-10 A563 GR A 02641784N ONS/QA/ NUT /29 Nut,HVY Hex CS 5/8-11 A325 GR A 02641237N ONS/QA/ NUT /30 Nut, Jam CS 2-3/4-4 A563 CL B 02641740N Non Safety Nuts ONS/NQ/ NUT /31 Nut.HVY Hex CS 1-1/8-7 A307 GR A 02641179N ONS/NQ/ NUT /32 Nut, Hex CS 1-3/8-6 SURE LOC 02641397 ONS/NQ/ NUT /33 Nut, Hex CS 2-4-1/2 2H SURE LOC 02641398 ONS/NQ/ NUT /34 Nut, Hex CS 7/8-9 GR8 02641864 ONS/NQ/ NUT /35 Nut.HVY Hex AS 3/4-10 A194 GR BM CL E 1007C5ANIC0E006 ONS/NQ/ NUT /36 Nut,HVY Hex CS 1-8 A307 GRADE A 02641211N ONS/NQ/ NUT /37 Nut,HVY Hex CS 1 8 A325 GRADE A 02641210N ONS/NQ/ NUT /38 Nut,HVY Hex CS 1-8 A563 GRADE A 02641301N ONS/NQ/ NUT /39 Nut. Hex CS 1-1/4-8 SA194 GR 7 MOIST SEP N205023473 l
ONS/NQ/ NUT /40 Nut,Manway 1006118-001 MK#160 OTSG SEC N232001153Q 1
F
Attachment C
-4 Catawba List of Fastener Samples (As of December 11, 1987)
Safety Related Bolts Sample Number MMIS Description MMIS Number CNS/QA/ BOLT /1 Bolt, Machine Hex HD CS 3/8-16X5 A-307/A 02623970N CNS/QA/ BOLT /2 Bolt, Machine Hex HD CS 7/16-14X5 J429/5 02623903N CNS/QA/ BOLT /3 Bolt, Machine Hex HD CS 7/16-14X5 SA449 02623902N CNS/QA/ BOLT /4 Bolt, Machine HVY Hex HD Alloy 3/4-10X4 02624010N CNS/QA/ BOLT /5 Bolt, Machine HVY Hex HDCS 3/4-10X6 A325 02622100N CNS/QA/ BOLT /6 Bolt, Secondary Handholds S/G 1 1/4-8X5 23240072N CNS/QA/ STUD /7 Stud. Alloy Steel 3/4-10X6 SA193 GR B7 1007B1ASICOB006060 CNS/QA/SCRW/8 Screw, CAP 3/4-10X4 Camshaft Bearing Cap 29020956N CNS/QA/SCRW/9 Screw, Cap Hex HD CS 3/4-10X4 J429/8 02653998N CNS/QA/ STUD /10 Stud,Viv 3/4-10X5 3/4 ASME SA564 T630 244401851N Non Safety Bolts CNS/NQ/ BOLT /11 Bolt, Hex HD Silicon Bron 3/8-16X1 F468 02621207N CNS/NQ/SCRW/12 Screw, Cap Hex E CS 7/16-20X2 GR 2 02652451 i
CNS/NQ/ BOLT /13 Bolt, Mach Hex HD CS 1 1/8-7X6 A193 GRB7 02622111 CNS/NQ/ BOLT /14 Bolt, Machine W/ Nut Hex HD STL 5/16-18X2 02621014 CNS/NQ/ BOLT /15 Bolt, Machine W/ Nut Hex HD STL 3/8-16X4 02621030
}
CNS/NQ/SCRW/16 Screw, Cap Hex HD SS 1/2-20X1 02654553 i
CNS/NQ/SCRW/17 Screw, Cap Hex HD CS 7/16-20x4 GR2 02652453 l
CNS/NQ/ BOLT /18 Bolt Lftng Lug Hex HD CS 1 1/2X6X14 A325 02624000 CNS/NQ/SCRW/19 Screw, Cap Soc HD STL 1/2-13X2 02651809 i
CNS/NQ/SCRW/20 Screw, Set SQ HD Alloy STL 1/2-13X3 02654488 Safety Related Nuts i
4 CNS/QA/ NUT /21 Nut,G1 Viv 6,3/4-10 SA194 GR 3M Borg W 244403773N CNS/QA/ NUT /22 Nut,HVY Hex 1 1/4-12X1 7/32X2 SA194/2H 02641775N CNS/QA/ NUT /23 Nut, Hex Alloy Stl 5/16-18 SA194 GR8 CL A 1007CIAMIC0A0005 CNS/QA/ NUT /24 Nut. Hex BR 5/16-18 X 1/4 X 1/2 02641923N l
CNS/QA/ NUT /25 Nut Hex GT VLV 6&8,5/8-11 SA194 GRADE 8M 244103251N i
CNS/QA/ NUT /26 Nut, Hex HD CS 5/8-11 X 9/16 X 15/16 02641915N l
CNS/QA/ NUT /27 Nut.Special Hex 1 1/2-6 A563 GR B 02642095N CNS/QA/ NUT /28 Nut Hex SS 3/8-16 A194/B8 02641990N I
CNS/QA/ NUT /29 Nut, Hex Jam i 1/4-20 ASTM A194 GR 2H G 244102420N CSS /QA/ NUT /30 Nut. Hex Jam 3/4-10 ASTM A194 GR 8M CK V 235100925N Non Safety Nuts CNS/NQ/ NUT /31 Nut,HVY Hex CS 3/4-10 SA194 GR 7 CL B 1007B3ANICOB006 CNS/NQ/ NUT /32 Nut, Hex HVY STL 3/4-10X47/64X1 1/4 2B 02641027 f
CNS/NQ/ NUT /33 Nut, Hex Silicon Bron 3/8-16X9/16X21/64 02641835 CNS/NQ/ NUT /34 Nut, Hex STL 7/8-14X3/4X1 5/16 ZN CH 02641011 CNS/NQ/ NUT /35 Nut.HVY Hex Alloy Stl 7/8-8 SA453 GR 660 1007BSAG1 LOA 013 CNS/NQ/ NUT /36 Nut.HVY Hex CS 1 1/4-8 SA194 GR 2H CL B 1007B2AN1 LOB 012 CNS/h0/ NUT /37 Nut.HVY Hex C3 1-8 A563/A 02641301N CNS/NQ/ NUT /38 Nut.HVY Hex CS 7/8-9 SA194 GR 2H CL B 1007B2AN1 COB 007 I
CNS/NQ/ NUT /39 Nut. Hex CS 5/8-18 SA194/2H 02641764N CNS/NQ/ NUT /40 Nut Hax Manhole Cover D/G Engine 29021177N l
l r
Attachment C 5-McGuire List of Fastener Samples (As of December 11, 1987)
Safety Related Bolts Sample Number KMIS Description MMIS Number t
MNS/QA/ BOLT /1 Bolt. Hex Head A-325 1 1/2-6X8 UNRC-2A 02622016N MNS/QA/ BOLT /2 Bolt Hex Head A-325 3/4-10X6 UNRC-2A 02621982N MNS/QA/ ROD /3 Rod, Threaded CS 3/4-10 SA193-B7 GR A 1007B1ARIC0A006 MNS/QA/ STUD /4 Stud,3/4-10XS SA193 GR B7 1007B1ASIC0A006050 MNS/QA/ STUD /5 Stud,3/4-10X5 1/4 SA193 GR B7 1007B1ASICOB006052 MNS/QA/ CAP /6 Capscrew, Hex Head 7/16-14X4 SA-193GR B7 02652967N MNS/QA/SCRW/7 Screw,CS Hex HD J429 Gr.8 1/2-13X3 1/2 02651885N 1
MNS/QA/SCRW/8 Screw,CS Hex HD 3/8-16X4 SA193 GR B7 02652950N MNS/QA/ BOLT /9 Bolt, Hex HD 1/2-13X7 3/4 SA307 GR A 1007A7ADIC0A004076 MNS/QA/ BOLT /10 Bolt, Hex HD 1/2-13X6 SA193 B8M 1007C9ADIC0A004060 Non Safety Bolts MNS/NQ/ BOLT /11 Bolt. Carriage Oval HD CS 3/8-16X6 02621512 MNS/NQ/SCRW/12 Screw Cap 1/2X8 UC 02654092 MNS/NQ/ BOLT /13 Bolt, Hex Head 1-8X4 A193 GR B7 For MSRs Non-Stock 5-L-1-1 MNS/NQ/ BOLT /14 Bolt. Machine CS Hex HD 1/2-13X4 A307/A 02623336 MNS/NQ/SCRW/15 Screw Cap 3/4X2 UC "Black Bethlehem Stl"02653580 MNS/NQ/SCRW/16 Screw Cap 3/4X2 UC "Plated KS Brand" 02653580 MNS/NQ/ BOLT /17 Bolt, Hex Head A-325 3/4-10X3 UNRC-2A 02621979N r
MNS/NQ/ BOLT /18 Bolt, Hex 5/8-11X3 1/4 SA193 GR B8M 1007C9ADIC0A005032 MNS/NQ/SCRW/19 Screw, Cap 3/4X8 02655071 MNS/NQ/SCRW/20 Screw,CS Hex Head Cap 1/2-13X1 GR 5 02653189 MNS/NQ/SCRW/21 Screw,CS Hex HD 3/4-10X4 1/2 A325 GR S 02653196 Safety Related Nuts MNS/QA/ NUT /22 Nut,3/4-10 SA194 GR B7 CLASS A 1007B3ANIC0A006 MNS/QA/ NUT /23 Nut.HVY Hex CS 3/4-8 A194 GR2H STRUCTRL 02641674N MNS/QA/ NUT /24 Nut, Hex 3/8-16 A307/A 02641513N MNS/QA/ NUT /25 Nut Hex 5/16-18 SA194 GR 2H CL B 02641748N MNS/QA/ NUT /26 Nut, Hexagon 7/16-14 ASTM A194 GR 8M 244102525N i
MNS/QA/ NUT /27 Nut, Hex CS 1/2-13X7/16X3/4 A307/A 02641512N MNS/QA/ NUT /28 Nut, Hex CS 1 1/2-8 A307 02641492N MNS/QA/ NUT /29 Nut HVY Hex CS 3/4-10 SA194 GR 2H 1007B2ANIC0A006 MNS/QA/ NUT /30 Nut. Hex 1/2-13 SA563 GRADE A 1007C7AMIC0A004 MNS/QA/ NUT /31 Nut Cap CS 1/2-13 SA194 GR 2H CL A 1007B2AZ1C0A004 9
Non Safety Nuts MNS/NQ/ NUT /32 Nut Hexagon 3/4 UNC 02641976 MNS/NQ/ NUT /33 Nut SS Hex 1/2-13 02641082 MNS/NQ/ NUT /34 Nut SS Hex 3/4-10 02641085 MNS/NQ/ NUT /35 Nut Hex Head,1/2-13X7/16 J429 GR8 02641076N MNS/NQ/ NUT /36 Nut Jam CS 3/8-16 A307 GR A STRUCTURAL 02641587N MNS/NQ/ NUT /37 Nut.20035 1-8UNC A582-GR416 P202635253 l
MNS/NQ/ NUT /38 Nut, Hex 7/16-14 SA563 GR A 1007C7AMIC0A0007 HNS/NQ/ NUT /39 Nut, Hex 3/4-10 SA194 GRADE 8M 1007CSAM1C0A006 MNS/NQ/ NUT /40 Nut. Hex SS ANSI B18.6.3-1975 3/8-16 02641944N MNS/NQ/ NUT /41 Nut Cap CS 9/16-12 SA194 GR 2R CL A 1007B2AZ1C0A0009
Attachment D Duko Power Company Response to NRC Compliance Bulletin 87-02 "Status and Schedule of the Evaluation of Fastener Testing Results" The evaluation of fastener testing results is not complete as of January 12, 1988.
Status of this effort is as follows:
All samples have been selected and forwarded to the lab.
All testing has been completed unless we determine that some of the samples require impact testing.
We have completed the review of approximately 70% of the test results at this time.
Up to this point, we have not discovered any significant deviation from the material specifications.
Barring any significant findings, we j
expect to complete our review, compilation, and submittal of the test results by February 11, 1988.
Any deviations requiring engineering or safety evaluation would extend this period.