ML20149E663

From kanterella
Jump to navigation Jump to search
Advises That Inservice Insp of Steam Generators A,B,C & D Completed on 871218 Per Tech Specs 4.4.5.5.a & 6.9.2.No Tubes Plugged.Further Info Will Be Provided Prior to 881218, Per Tech Spec 4.4.5.5.6
ML20149E663
Person / Time
Site: Catawba 
Issue date: 12/31/1987
From: Tucker H
DUKE POWER CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
NUDOCS 8801130433
Download: ML20149E663 (1)


Text

-- -

DUKE POWER GOMPANY i

15.0. Itox 33180 cilAHLOTTE N.O. 98949 IIAL lt TUCKER rut.e rnons vwa persionet (704) 0NMI stuaan renotiction December 31, 1987 i

I t

U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D. C. 20555

Subject:

Catawba Nuclear Station, Unit 1 Docket No. 50-413 i

Steam Generator Tube Inspection 1

Gentlemen:

Pursuant to Technical Specification 4.4.5.5.a and 6.9.2, please be advised that-an inservice inspection of Catawba Nuclear Station Unit 1 Steam Generators A, B, C, and D was completed on December 18, 1987.

No tubes were plugged as the result of the inspection.

Further information will be provided prior to December 18, 1988, pursuant to Technical Specification 4.4.5.5.b.

Very truly yours, l

[

i p

i k S4'

.+

i

/

t llal B. Tucker j

i JGT/1180/sbn Attachment xc:

Dr. J. Nelson Grace, Regional Administrator U. S. Nuclear Regulatory Commission i

Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Mr. P. K. Van Doorn NRC Resident Inspector Catawba Nuclear Station 1

8801130433 871231 4

PDR ADOCK 05000413 0

PDR

\\

i

-