ML20148M201

From kanterella
Jump to navigation Jump to search
Acknowledgement of the U.S. Department of Energys Submittal of the Savannah River Site Saltstone Disposal Facility Performance Assessment for Technical Review and Closure of the April 30, 2012, Type-IV Letter of Concern
ML20148M201
Person / Time
Site: PROJ0734
Issue date: 07/10/2020
From: Patricia Holahan
NRC/NMSS/DDUWP/LLWB
To: Folk J
US Dept of Energy, Savannah River Operations Office
Felsher H
References
Download: ML20148M201 (3)


Text

July 10, 2020 Mr. James L. Folk, Jr., Assistant Manager Waste Disposition Department of Energy Savannah River Operations Office P.O. Box A Aiken, South Carolina 29802

SUBJECT:

ACKNOWLEGEMENT OF THE U.S. DEPARTMENT OF ENERGYS SUBMITTAL OF THE 2020 SAVANNAH RIVER SITE SALTSTONE DISPOSAL FACILITY PERFORMANCE ASSESSMENT, FOR TECHNICAL REVIEW AND CLOSURE OF THE APRIL 30, 2012, TYPE-IV LETTER OF CONCERN

Dear Mr. Folk:

This letter acknowledges the U.S. Nuclear Regulatory Commissions (NRCs) receipt of the U.S.

Department of Energys (DOEs) 2020 Savannah River Site Saltstone Disposal Facility (SDF)

Performance Assessment (PA). In its transmittal letter dated July 6, 2020, (NRCs Agencywide Documents Access and Management System [ADAMS] Accession No. ML20189A591) the DOE requested that the NRC conduct a technical review of the 2020 SDF PA, Revision 0 under Section 3116(b) of the Ronald W. Reagan National Defense Authorization Act for Fiscal Year 2005.

The NRC has initiated an Acceptance Review for the 2020 SDF PA. The NRC expects to complete the Acceptance Review by October 5, 2020. Upon completion of the Acceptance Review, the NRC will send a letter to the DOE describing the results of the Acceptance Review.

The letter will also contain a schedule for the complete NRC technical review.

The 2020 SDF PA replaces the 2009 SDF PA that led to the NRC issuance of the April 12, 2012, Type-IV Letter of Concern (ADAMS Accession No. ML120650576) for the SDF. Since the NRC issued the previous SDF Technical Evaluation Report in 2012, the DOE has:

(1) significantly changed the design of the saltstone disposal structures; (2) significantly changed the design of the proposed SDF closure cap; (3) substantially revised the SDF groundwater model; and (4) conducted significant new research regarding the physical and chemical properties of the saltstone wasteform.

The 2020 SDF PA and those DOE informational and design changes since the 2009 SDF PA represent a significant departure from the natural and engineered system that formed the basis for the NRC 2012 Type-IV Letter of Concern. Therefore, the NRC is administratively closing the 2012 Type-IV Letter of Concern. The fundamental areas that led to the Type-IV Letter of Concern will be reviewed within the entire scope of the 2020 SDF PA and supporting documents. The NRC will make conclusions on whether the NRC has reasonable assurance that the performance objectives of Title 10, Code of Federal Regulations (10 CFR) Part 61 will be met.

J. Folk 2

In accordance with 10 CFR Section 2.390, Agency Rules of Practice and Procedure, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of ADAMS. The ADAMS database is accessible from the NRC Web site at: http://www.nrc.gov/readingrm/adams.html If you have any questions or need additional information, then please contact Mr. Harry Felsher of my staff at Harry.Felsher@nrc.gov or at 301-415-6559.

Sincerely, Patricia K. Holahan, Director Division of Decommissioning, Uranium Recovery, and Waste Programs Office of Nuclear Material Safety and Safeguards Docket No. PROJ0734 cc: WIR ListServ Patricia K.

Holahan Digitally signed by Patricia K. Holahan Date: 2020.07.10 10:51:54 -04'00'

J. Folk 3

SUBJECT:

ACKNOWLEGEMENT OF THE U.S. DEPARTMENT OF ENERGYS SUBMITTAL OF THE 2020 SAVANNAH RIVER SITE SALTSTONE DISPOSAL FACILITY PERFORMANCE ASSESSMENT, FOR TECHNICAL REVIEW AND CLOSURE OF THE APRIL 30, 2012, TYPE-IV LETTER OF CONCERN DATED July 10, 2020 DISTRIBUTION:

ARidge, NMSS GAlexander, NMSS HArlt, NMSS KPinkston, NMSS RLGladney, NMSS LDesotell, NMSS ADAMS Accession Number: ML20148M201

  • via email OFFICE NMSS/DUWP NMSS/DUWP NMSS/DUWP OGC NMSS/DUWP NAME HFelsher CMcKenney*

SKoenick*

APessin*