f:

ws em (hh I

Florida A,

-W l

gr

))

AQ

~

CO R PO H A f tO N N

..g December 5, 1980 Q

j File:

3-0-3-a-3

  1. 3-120-18 i

Mr. Robert W. Reid i'

Branch Chief Operating Reactors Branch #4 THIS DOCUMENT CONTAINS Division of Operating Reactors POOR QUAUTY PAGES U. S. Nuclear. Regulatory Commission i

Washington, D. C. 20555 i

Subject:

Crystal River Unit 3 Docket No. 50-302 Operating License No. DPR-72 Technical Specification Change Request No. 27 l

Design.Information and Technical Specifications for Reactor Coolant Pump Power Monitors, November 29, 1978

Dear Mr. Reid:

Enclosed are three (3) originals and forty (40) copies of the following i

documents related to the Pump Power Monitor 7 KV Isolation System-t 1)

Functional Test Procedure for Pump Monitor Isolation Subsystem i

(with results)

L 2)

Pump Monitor Response Time Calculations i

3)

Vitro Seismic Test Procedure i

4)

Vitro High Voltage Tests Procedure 5)

Contact Monitor Signal Resistance Calculations j

6)

RC Pump Monitor Isolation System Vitro Laboratories Division B&W No. 036104 Customer Work Authorization W.A. No. 651-148 l

This information satisfies the final concern identified in your letter j

of January' 17, 1980, regarding Technical Specification Change Request i

No. 27 Design Information and Technical Specification for Reactor Cool-ant Pump Power Monitors, November 29, 1978.

l l

Your letter requested an analysis to demonstrate the Reactor Coolant Pump. Power Monitors and RPS have sufficient isolation to prevent being damaged or disabled due to a fault voltage resulting from any failure or l

combination of failures of the non-qualified equipment or of the inter-connecting cabling between the non-qualified equipment and the qualified equipment of the Reactor Coolant Pump Power Monitors.

{

f8012 0 9 0 J A6-j General Office 3201 Thirty fourth Street South e P O Box 14042 St etersburg, Flonda 33733. 813--666-5151

Mr. Robert W. Reid Page Two December 5, 1980 l

After a preliminary analysis showed that the original isolation devices may not be adequate, we discussed developing a relay isolation system or an optical isolation system with John Burdoin and Sheryl Wookey, Febru-ary 22, 1980.

The optical isolators were finally selected due to their superior isolation and discussed with John Burdoin on May 23, 1980.

The attached reports listed above document the functional, seismic, and high voltage tests and qualifications.

We have informed John Burdoin that the completed reports are being sub-mitted to you with an extra copy to him.

Very truly yours, FLORIDA POWER CORPORATION N*

Patsy Y. Baynard Manager Ntclear Support Services a cachments Baynard(T02)D1-1 l

l

9 UNITED STATES OF AMERICA NUCLFAR REGULATORY COMMISSION IN THE MATTER OF DOCKET NO. 50-302 FLORIDA POWER CORPORATION f

CERTIFICATE OF SERVICE P. Y. Baynard deposes and says that the following has been served on the Chief Executive of Citrus County, Florida by deposit in the United States mail, addressed as follows:

Chairman, Board of County Commissioners of Citrus County Citrus County Courthouse Inverness, Florida 32650 An original copy c:f Information for Tech Spec Change No. 27.

FLORIDA POWER CORPORATION QnM. La Ff. Y. Segnard' (/

Manager Nuclear Support Services SWORN TO A.O SUBSCRIBED BEFORE ME THIS STH DAY OF DECEMBER, 1980.

fl4)vmgf//.

k>d>n OLV

/

Notary Public Notary Public State of Florida at Large My Commission expires: May 29, 1984 (NOTARIAL SEAL)

Chisamore(CertServ)D12

i I

o STATE OF FLORIDA i

COUNTY OF PINELLAS P.

Y.

Baynard states that she is the Manager, Nuclear Support Services of Florida Power Corporation; that.she is authorized on the part of said company to sign and file with the Nuclear Regulatory Commission the information attached hereto; and that all such statements made and matters set forth therein are true and correct to the best of her knowledge, information and belief.

l A$Aw

% dAAl' F.()f. Bdy#ard Subscribed and sworn to before me, a Notary Public in and for the State and County above named, this 5th day of December,1980.

lkgujfn((/

c24/PW

/

Notary Public Notary Public, State of Florida at Large, My Commission Expires:

May 29, 1984 Chisamore(Notary)(012)