ML20148J135
| ML20148J135 | |
| Person / Time | |
|---|---|
| Site: | Yankee Rowe |
| Issue date: | 03/07/1973 |
| From: | Vandenburgh D YANKEE ATOMIC ELECTRIC CO. |
| To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| Shared Package | |
| ML20148J142 | List: |
| References | |
| NUDOCS 8011210198 | |
| Download: ML20148J135 (1) | |
Text
t l
1 j
3 YANKEE ATOMIC ELECTRIC COMPANY 4
_ ;;g 20 IURNPIKE ROAD, WESTBOROUGH. MASSACHUSETTS 01581 TLLEPHONE 617 366 9011
=:.-
March 7, 1973 United States Atomic Energy Commission 970 Broad Street Newark, New Jersey 07102 Attention: Directorate of Regulatory Operation Region I
References:
-(a) ' Operating License No. DPR-3 (Docket No. 50-29)
N (b) Yankee letter to USAEC dated January 15, 1973 (c) USAEC letter to Yankee dated February 7,1973
Dear Sir:
l We informed you in Reference (b) that althodsh we had completed the valve wall thickness verification program at Yankee P. owe we had been unsuccessful in i
ultrasonically measuring five of the eight reactor coolant loop isolation valves as a result of variations in grain structure.
Your reply, Reference (c), requested us to develop an alternate method which voule produce the necessary dimensional data and to advise you, within y
30 days, of our proposed program to accun.ulate this information.
We now wish to inform you that later attempts to ultrasonically measure thase valves were succesaful. A Sonic instrument was used with a recently de-veloped damped transducer which operates in the 1 Edz frequency range.
Pre-vi: sly, a Krautkrater instrument was used with a 2h MHz transducer.
The measuretants revealed areas of tne valves that were below the minimum thickness requirements of Code ANSI B16 5 Weld overlay is currently being applied to thess areas to increase the wall thickness.
We anticipate this werk will be completed by March 1h,1973 y
7ne documentaticn package for the verification of the wall thicknesses of the eight reactor coolant loop isolation valves will te available at the plant
.J for review by your inspector.
Very truly yours, Uvbb
/
D. E. VandenburCh I
}
Vice President i
18011210[9f
},
--ys-si.,i-
---c.-r e-'
-r".
ew'v---
^ee
'---5--